• Title/Summary/Keyword: Fire Management

Search Result 1,689, Processing Time 0.032 seconds

A Study on martial arts when Equipped with Weapons, Clothes and Other Accessories (복식과 무기의 갖춤 상황에서의 무예연구)

  • Hwang, Ho-Young;Choi, Jea-Geun
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.413-421
    • /
    • 2013
  • We, currently settled on the peninsula, have a long history and our ancestors lived over the vast land further to the central Asia and northern China. Normally, our ancestors traded with many countries, but they fought battles when they were on bad terms and many countries emerged and disappeared. In this history, a variety of cultures have been established and the traditional martial arts is a part of those cultures. Our martial arts has been almost severed because of the development of fire weapons in the late Chosun Dynasty, Japan's colonial rule, and 1950-53 Korean War. Fortunately, we can study the traditional martial arts from history books, the records on the martial art books and relics. Muyeadobotongji, the martial art book published in the late Chosun Dynasty, regrets the negligence of martial arts Giyae(arts) after Japanese Invasion of Korea in 1592 and the Manchu war of 1636 and accommodated the martial art skills from Chosun, China and Japan. It is useful for studying martial arts, because it contains detailed description and drawings, clothes and accessories, and the specification of the weapons. However, the problem is the level of Giyae of the martial arts organization and individuals based on Muyeadobotongji vary and some organizations are arguing about the numbers.

Musculoskeletal Diseases in 119 Rescuers (119구급대원 구급활동에 따른 근골격계 질환 연구)

  • Shin, Dong-Min;Hong, Eun-Jeong;Kim, Gyung-Yong;Kim, Jee-Hee;Moon, Tae-Young
    • Journal of Digital Convergence
    • /
    • v.11 no.9
    • /
    • pp.209-219
    • /
    • 2013
  • The purpose of this study is to investigate the prevalence and to describe the correlation between the working period and musculoskeletal diseases of 119 rescuers. We conducted 485 surveys from 547 rescuers working in Gyeonggi-do from November 5 to December 20, 2011. The collected data were analyzed by cross tabulation analysis, chi-square test, and correlation analysis using PASW 18.0. The p value was set at p<.05. The prevalence of musculoskeletal diseases, 328(67.6%) rescuers suffering from musculoskeletal diseases. General characteristics included gender(p<.01), age(p<.01), marriage(p<.001),household chores(p<.05), working period(p<.001). The correlation between physical loading of subjects and musculoskeletal diseases was significant(p<.001). The rescuers felt the pain at lower back(36.4%), shoulders(19.2%), neck(14.9%), hip/ankles(13.2%), hand/wrist/fingers(12.0%), elbow(4.3%). This study showed that working period and physical loading affect musculoskeletal diseases.

Study on the method of safety diagnosis of electrical equipments using fuzzy algorithm (퍼지알고리즘을 이용한 전기전자기기의 안전진단방법에 대한 연구)

  • Lee, Jae-Cheol
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.223-229
    • /
    • 2018
  • Recently, the necessity of safety diagnosis of electrical devices has been increasing as the fire caused by electric devices has increased rapidly. This study is concerned with the safety diagnosis of electric equipment using intelligent Fuzzy technology. It is used as a diagnostic input for the multiple electrical safety factors such as the use current, cumulative use time, deterioration and arc characteristics inherent to the equipment. In order to extract these information in real time, a device composed of various sensor circuits, DSP signal processing, and communication circuit is implemented. The fuzzy logic algorithm using the Gaussian function for each information is designed and compiled to be implemented on a small DSP board. The fuzzy logic receives the four diagnostic information, deduces it by the fuzzy engine, and outputs the overall safety status of the device as a 100-step analog fuzzy value familiar to human sensibility. By experiments of a device that combines hardware and fuzzy algorithm implemented in this study, it is verified that it can be implemented in a small DSP board with human-friendly fuzzy value, diagnosing real-time safety conditions during operation of electric equipment. In the future, we expect to be able to study more intelligent diagnostic systems based on artificial intelligent with AI dedicated Micom.

The Method of Evaluating The Potential for Conversion Legal Problems with Conversion And Basic Capacity of Vacant Onces in Tokyo

  • Sato, Kouichi;Matsumura, Shuichi;Namiki, Kenji
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.301-306
    • /
    • 2002
  • In Japan, the vacancy rates of office buildings have been at high in big cities since 1992. This problem is especially acute in Tokyo, where it is estimated that over 2.27 million square meters of office floor area will be oversupplied in 2003: big urban redevelopment projects will be completed in 2003. Under these circumstances, International Cooperative Research and Development on Sustainable Urban Management by Conversion of Buildings, called “SUMCOB”, has been carried out. This research aims to regenerate urban areas by converting redundant offices into flats, although instances of conversion are still very few in Japan. This paper introduces part of current results by SUMCOB, and discusses legal problems with conversion and basic capacity of vacant offices in Tokyo. It has been confirmed that there are no constraints concerned with Real Estate Registration Law (although it requires the change of the registration after conversion). and City Planning Law. However, some criteria are incompatible with Building Standard Law and Fire Service Law if the use of the building is changed from offices to flats. Typical incompatibility between offices and flats is lightening. If the buildings do not satisfy criteria for flats, the cost of renovation works for conversion will increase. To examine the basic capacity of vacant office buildings for conversion, field surveys in Tokyo have carried out at three areas: Kodenmacho (Chuo-ku), Toranomon (Minato-ku), and Iwamonocho (Chiyoda-ku). They are typical office areas that are included in center core of Tokyo. In Chuo-ku, the oldest commercial area in Tokyo, textile merchants have been located their headquarters. In Minato-ku, many rental office buildings have been located and several large scale redevelopments are advancing. Chiyoda-ku includes Marunouchi area, which is the prime office area in Japan. Thirty percent of the buildings in survey areas suffer from over twenty percent vacant floor rate, and fifty five percent were constructed before 1990. Especially most of buildings over forty percent vacant floor rate were constructed in 1980s. Vacant office problems haven't been seen in old buildings in Tokyo yet. The number of dwelling units made from office space will influence the conversion scheme. Seventy percent of the office buildings in survey areas have floor area of less than two hundred square meters. If they have been subdivided into two bedrooms type or three bedrooms type, the number of dwelling units in a floor would be less than three. The difficulty of conversion planning derives from frontage size, depth size, and their proportion. The five categories are proposed to grasp actual requirements for converting offices into flats.

  • PDF

Analysis of trunk angle and muscle activation during chest compression in 119 EMTs (가슴압박시 구급대원의 체간 각도와 근활성도 분석)

  • Shin, Dong-Min;Lee, Chang-Sub;Kim, Seung-Yong;Kim, Chang-Kook;Hong, Eun-Jeong;Lee, Young-Chul;Choi, Ga-Ram;Kim, Gyoung-Yong;Jang, Mun-Sun;Kim, Jeong-Hee;Han, Boong-Ki;Lee, Jong-Kun;Tak, Yang-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.18 no.3
    • /
    • pp.7-18
    • /
    • 2014
  • Purpose: We aimed to investigate trunk angle and muscle activation of the extremity and back to evaluate the effect of chest compression on work-related musculoskeletal disorders in 119 emergency medical technicians (EMTs). Methods: Eighteen 119 EMTs performed 2-minute chest compression without interruption on a cardiopulmonary resuscitation manikin, during which we measured changes in the trunk and shoulder joint angles, muscle activation (triceps brachii, biceps brachii, erector spinae, gluteus maximus, pectoralis major, rectus abdominis, and rectus femoris) and chest compression accuracy. Results: The decrease in trunk angle by trunk muscle activation was the highest in event 2, the major direction of chest compression. Both shoulder joint angles had no significant difference. Muscle activation of the triceps brachii (p < .01), biceps brachii (p < .05), rectus abdominis (p < .05) and rectus femoris (p < .01) significantly increased during the compression phase compared with the decompression phase, with the rectus femoris showing an increase of 19%. Muscle activation of the erector spinae significantly increased in the decompression phase compared with the compression phase (p < .01). Conclusion: 119 EMTs mainly use the triceps brachii, biceps brachii and pectoralis major muscles during chest compression.

A Study on the Status Investigation for Establishing the Disaster Management Cooperation System at Educational Institutions (교육기관의 재난관리 협력체계 구축을 위한 실태조사 연구)

  • Park, Soyeon;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.405-412
    • /
    • 2017
  • Due to the increase in awareness of school safety after the Sewol ferry disaster, it became necessary to improve the capability to prevent a safety accident at school and to respond to an accident in the case of emergency as well as the awareness of safety issues. Therefore, it is necessary for educational institutions to reinforce safety measures autonomously, and the importance of supports and cooperation from agencies related to the safety of local community is also emphasized. However, it is quite difficult for schools and the Office of Education to prevent safety accidents only with their own capability, and safety accidents can be prevented through the supports from agencies involved in safety of local communities. Therefore, the status and cooperation system of educational institutions and relevant authorities were reviewed theoretically in this study. In addition, a field investigation was carried out to examine the awareness of disaster and safety, and cooperation status of officials in charge of practical disaster-related works. Moreover, this study intended to present a measure to establish the safety cooperation system between educational institutions and agencies involved in safety of local community in the future based on the findings.

Effect of Non-Equilibrium Condensation on Force Coefficients in Transonic Airfoil Flow (천음속 에어포일 유동에서 비평형 응축이 Force Coefficients 에 미치는 영향)

  • Jeon, Heung Kyun;Choi, Seung Min;Kang, Hui Bo;Kwon, Young Doo;Kwon, Soon Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1009-1015
    • /
    • 2014
  • The present study investigated the effects of non-equilibrium condensation with the angle of attack on the coefficients of pressure, lift, and drag in the transonic 2-D flow of NACA0012 by numerical analysis of the total variation diminishing (TVD) scheme. At $T_0=298k$ and ${\alpha}=3^{\circ}$, the lift coefficients for $M_{\infty}=0.78$ and 0.81 decreased monotonically with increasing ${\Phi}_0$. In contrast, for $M_{\infty}$ corresponding to the Mach number of the force break, $C_L$ increased with ${\Phi}_0$. For ${\alpha}=3^{\circ}$ and ${\Phi}_0=0%$, $C_D$ increased markedly as $M_{\infty}$ increased. However, at ${\Phi}_0=60%$ and ${\alpha}=3^{\circ}$, which corresponded to the case of the condensation having a large influence, $C_D$ increased slightly as $M_{\infty}$ increased. The decrease in profile drag by non-equilibrium condensation grew as the angle of attack and stagnation relative humidity increased for the same free stream transonic Mach number. At ${\Phi}_0=0%$, the coefficient of the wave drag increased with the attack angle and free stream Mach number. When ${\Phi}_0$ > 50%, the coefficient of the wave drag decreased as ${\alpha}$ and $M_{\infty}$ increased. Lowering ${\Phi}_0$ and increasing $M_{\infty}$ increased the maximum Mach number.

Remote control system for management of a stall using PDA (PDA를 이용한 축사관리 원격제어 시스템)

  • Kim, Tae-Soo;Chun, Joong-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.1010-1013
    • /
    • 2009
  • The youths of the farming village have moved to the metropolis, thus the most of the manpower which engages to a production remained in the village reaches layer old age and all thing sprouts long the whole and it is one. So to remove the waste of barn rather than to give feed to the livestock is hard that what step all automation of this part is necessary. Consequently we have developed the automation system in order to reduce the massive death of the livestock at the time of intense cold and hot. The system will be able to clean the waste of the barn and confront quickly in the change of temperature which is sudden it came. And we proposed also the system that will be able to watch at real-time and monitor the operational environment from a remote using CCD camera. In this paper, we proposed the remote control system which uses PDA in order to control the automation system of a stall while moving. The proposed system was embodied in order for the control and the monitor while the user is mobile using PDA screens. We also added a protection system in that system. The system sends the case warning and SMS while will have the fire and the intrusion from the outside and prevents a robbery.

  • PDF

Changes on Quality of Acanthopanacis cortex and Aralia elata Shoots by Blanching Conditions and Thawing Methods (오가피와 두릅 순의 blanching 조건 및 해동방법에 따른 품질 변화)

  • Lee, Soo-Jin;Kim, Ja-Min;Kwon, O-Jun;Jeong, Yong-Jin;Woo, Sang-Chul;Yoon, Kyung-Young
    • Food Science and Preservation
    • /
    • v.18 no.3
    • /
    • pp.302-309
    • /
    • 2011
  • This study was performed to analyze the physicochemical and sensory properties of Acanthopanacis cortex and Aralia elata according to their blanching conditions and thawing methods. In terms of their Hunter colors, the A. cortex and A. elata that were blanched without adding salt to them for 7 min and 4 min, respectively, had the highest L values. The chlorophyll content (148.7 mg%) of A. cortex that was blanched with 1% salt for 4 min was higher than those of the other samples, and the chlorophyll content of A. elata was 32.4 mg% when it was blanched for 4 min without salt addition. The sensory test results showed the highest overall preference for the sample that was blanched without salt for 4 min among all the samples. The Hunter color of A. cortex did not significantly differ with different thawing methods, but the value of A. elata that was thawed in a microwave oven was higher than those of the other samples. The chlorophyll contents of A. cortex and A. elata that were thawed in a microwave oven were the highest among all the samples. As for the overall preference for the samples according to the thawing method, A. cortex and A. elata scored highest in the case of thawing at $25^{\circ}C$ and in a microwave oven, respectively.

Analysis and cause of defects in reinforced cement concrete lining on NATM tunnel based on the Precise Inspection for Safety and Diagnosis - Part I (정밀안전진단 결과를 활용한 NATM (철근)의 라이닝 결함 종류별 발생원인 및 분석 - Part I)

  • Choo, Jinho;Lee, Inmo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.1-29
    • /
    • 2019
  • Related to the previous paper on the typical crack pattern of tunnel lining with NATM, the characteristic defects in reinforced cement concrete lining of NATM tunnel have analyzed with the precise inspection with safety and diagnosis (PISD) by KISTEC. Depending on the reinforcing materials, steel rebar, steel fiber, and glass fiber have been implemented to reinforcing lining in various NATM tunnel constructions. Reinforcing lining with rebar are prevailed on NATM tunnel to countermeasure the weak geological circumstances, to pursuit the economical tunnel sections, and to resist the risk of tunnel deterioration. By the special act on the safety control of public facilities, the reinforced NATM tunnels for more than 1 km length are scrutinized closely to characterize defects; crack, reinforcement exposure, and lack of lining. Crack resistance by reinforcing is shown in comparison with the normalized crack to the length of tunnel. Typical exposed reinforcements in lining have exemplified with various sections. The lack of lining due to the mal-construction, spalling, fire, earthquake and leaching has been analyzed. The cause and mechanism with the field inspections and other studies has also been verified. Detailed cases are selected by the above concerns as well as the basic information from FMS (Facilities Management System). Likewise the previous paper, this study provides specialized defects in reinforced lining of NATM and it can be widely used in spreading the essential technics and reporting skills. Furthermore, it would be advised and amended for the detail guideline of Safety Diagnosis and PISD (tunnel).