• Title/Summary/Keyword: Fire Hazard Assessment

Search Result 107, Processing Time 0.029 seconds

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

A Study on the Assessment of Hazardous Properties of the Oxidizing Solids (산화성고체의 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Park, Chul-Woo;Song, Haak
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.9-16
    • /
    • 2009
  • Chemical products have had an favorable influence on our everyday life, and contributed very much to the development of human culture. According to the rapid change of industry and the development of scientific technique the using chemical products are increasing more and more. Chemical products can have any hazardous property such as flammability or explosiveness. There are occurring many accidents in the international trade due to the different classification and labelling of chemicals produced in various countries. The main purpose of this work is the development of global standard test methods for the chemicals, and the classification and labelling in building block approach by means of the basic technical data. Oxidizing solids, combustible solids, spontaneously combustible materials, water-prohibitive materials, flammable liquids, self-reactive materials and oxidizing liquids have been classification The first Experiment have tested Oxidizing solids of third five. The results have been classified according to the hazard material safety regulation and the UN regulation, and summarized in a data-base.

Heat Risk Assessment of Wood Coated with Boron/Silicone Sol (붕소/실리콘 졸로 도포된 목재의 열위험성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.9-20
    • /
    • 2019
  • This study was examined fire risk properties of wood specimen for the constructional interiors, especially focusing on the fire performance index (FPI) and the fire growth index (FGI) as heat hazard characteristics. Flame retardants were synthesized using boric acid, boronic acid and tetraethoxyorthosilicate. Heat release characteristics were measured by using a cone calorimeter (ISO 5660-1) and cypress was used. The external heat flux as fire intensity was maintained at 50 kW/㎡. The measured fire performance index (FPI) after burning was increased by 1.6 times for boric acid/silicone (BA/Si) sol, each 1.1 times for isobutylboronic acid/silicone (IBBA/Si) sol and phenylboronic acid/silicone (PBA/Si) sol compared with cypress. Fire risk by the fire performance index was increased BA/Si, IBBA/Si ≈ PBA/Si order. The fire growth index was decreased 94% for the BA/Si and 8% for the IBBA/Si sol, and was increased by 17% for the PBA/Si sol. Fire risk by the fire growth index was increased BA/Si, IBBA/Si, PBA/Si order. Overall fire risk was higher in the order of BA/Si < IBBA/Si < PBA/Si.

Fire Risk Rating Evaluation of Organic Insulation Materials (유기 단열재의 화재위험성 등급 평가)

  • You, Ji Sun;Jeon, Nam;Chung, Yeong-jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.417-422
    • /
    • 2021
  • In this study, poly isocyanurate foam (PIR), poly urethane foam (PUR), and phenol foam (PF) of organic insulation materials were selected, and investigated using a cone calorimeter, as per ISO 5660-1. Standard materials (PMMA) were used to standardize the fire hazard assessment, and the fire risk was classified and evaluated by Chung's equations-III and IV. The fire performance index-II value of Chung's equations-II was the highest value with PF of 14.77 s2/kW. And the PUR was 0.08 s2/kW, the lowest value of fire performance index-II value. The fire growth index-II value was the lowest value with PF of 0.01 kW/s2. And the PUR was 1.14 kW/s2, the highest value of fire growth index-II value. The fire performance index-III (FPI-III) of Chung's equations-III had the lowest value for PUR (0.11) and the highest for PF (20.23). The PUR showed the highest value of the fire growth index-III (FGI-III) as 14.25, while the PF exhibited 0.13 regarded as the safest materials. The fire risk index-IV (FRI-IV) value of Chung's equation-IV was in the following order: PUR (130.03) >> PIR (19.13) > PMMA (1.00) > PF (0.01). Therefore, it was concluded that the fire risk associated with PF is the lowest, whereas that associated with PUR is the highest.

Effect of Powder Condition on the Fire and Explosion Characteristics of Suspended and Deposited Dusts (부유 및 퇴적의 분체 조건이 화재폭발 특성에 미치는 영향)

  • Han, Ou-Sup;Seo, Dong-Hyun;Choi, Yi-Rac;Lim, Jin-Ho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.229-236
    • /
    • 2022
  • An experimental investigation was conducted on the influences of median size, dust concentration, dust condition (cloud and layer) for the fire and explosion hazard assessment of dusts with the same powder property. For this purpose, tests have been performed in accordance with 20 L explosion sphere, thermogravi- metric analyze, combustion rate tester (UN method). We investigated the explosion characteristics and flame propagation velocity (FPV) in dust cloud and the flame spread velocity(FSV) over dust layer on 8 dust samples with different particle sizes of 4 types of dusts (Sugar, Mg, Al, Zr). An explosion hazard increased with decreasing particle size in Mg and Al dust clouds, but sugar did not show the effect of explosion hazard due to particle size change in dust clouds. The flame propagation velocity (FPV) of suspended dusts increased significantly when the particle size decreased from micro to nano than the variation of particle size in micro range. The flame spread velocity (FSV) over dust layer showed a tendency to increase over the inclined dust layers (30° slope) rather than the horizontal dust layers (0° slope). The flame spread rate (FSV) over dust layers increased on the inclined dust layer (30° slope) rather than the horizontal dust layer (0° slope) and was higher upward flame than the downward flame in condition of inclined dust layers(30° slope).

Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module (고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가)

  • SangJin Lim;MinGi Kim;Su Kim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.76-85
    • /
    • 2023
  • Demand for hydrogen as a renewable energy resource is increasing. However, unlike conventional fossil fuels, hydrogen requires a dedicated refueling station for fuel supply. A risk assessment of hydrogen refueling stations must be undertaken to secure the infrastructure. Therefore, in this study, a risk assessment for hydrogen refueling stations was conducted through both qualitative and quantitative risk assessments. For the qualitative evaluation, the hydrogen dispenser module was evaluated as two nodes using the hazard and operability (HAZOP) analysis. The risk due to filter clogging and high-pressure accidents was evaluated to be high according to the criticality estimation matrix. For the quantitative risk assessment, the Hydrogen Korea Risk Assessment Module (Hy-KoRAM) was used to indicate the shape of the fire and the range of damage impact, and to evaluate the individual and social risks. The individual risk level was determined of to be as low as reasonably practicable (ALARP). Additional safety measures proposed include placing the hydrogen refueling station about 100m away from public facilities. The social risk level was derived as 1E-04/year, with a frequency of approximately 10 deaths, falling within the ALARP range. As a result of the qualitative and quantitative risk assessments, additional safety measures for the process and a safety improvement plan are proposed through the establishment of a restricted area near the hydrogen refueling station.

Assessment of steel structures designed for progressive collapse under localized fires

  • Behrouz Behnam
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.279-292
    • /
    • 2023
  • Structural design against the progressive collapse has been a vital necessity for decades due to occasional tragic events. The question of whether designed structures against the progressive collapse are still robust if subjected to multi-hazard scenarios containing column removal and successive localized fires is ad-dressed in the current study. Two seven-story steel structures with an identical area but different structural configurations of 4- and 5-bays are designed against the progressive collapse; the structural components are also fireproofed for a 60 min fire resistance. The structures are then subjected to different column re-moval scenarios over different stories followed immediately by localized fires. Results indicate that the structures are not able to keep their stability under all of the considered scenarios; the 4-bay structure is more vulnerable than the 5-bay structure. It is also indicated that upper stories are more sensitive toward the considered scenarios than lower stories. To advance structural safety, two strategies are adopted: in-creasing the thickness of the insulation materials to reduce the thermal effects, or, increasing the safety fac-tor (ΩN) of the structures when designing against the progressive collapse. As for the first strategy, provid-ing a 35% and a 25% increase in the insulation thicknesses of the structural components of the 4-bay and 5-bay structures, respectively, can prevent a progressive collapse to trigger. As for the second strategy, in-creasing ΩN by 10% can enhance the structural integrity to where no collapse occurs under all of the sce-narios.

A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity (인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구)

  • Lee, Dong Hoon;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.

Probabilistic Risk Evaluation Method for Human-induced Disaster by Risk Curve Analysis (확률.통계적 리스크분석을 활용한 인적재난 위험평가 기법 제안)

  • Park, So-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.57-68
    • /
    • 2009
  • Recently, damage scale of human-induced disaster is sharply increased but its occurrences and damages are so uncertain that it is hard to construct a resonable response & mitigation plan for infrastructures. Therefore, the needs for a advanced risk management technique based on a probabilistic and stochastic risk evaluation theory is increased. In this study, these evaluation methods were investigated and a advanced disaster risk evaluation method, which is based on the probabilistic or stochastic risk assessment theory and also is a quantitative evaluation technique, was suggested. With this method, the safety changes as the result of fire damage management for recent 40 years was analyzed. And the result was compared with that of Japan. Through the consilience of the traditional risk assessment method and this method, a stochastical estimation technique for the uncertainty of future disaster's damage could support a cost-effective information for a resonable decision making on disaster mitigation.

A Study on the Ignition Hazards of Flammable Mixtures by Radio Frequency Radiation (고주파 방사에 의한 가연성가스의 점화 위험성 고찰)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1749-1751
    • /
    • 1998
  • Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.

  • PDF