• Title/Summary/Keyword: Fire Fire Safety Policy

Search Result 90, Processing Time 0.022 seconds

Study for the Method to Secure the Safety of Fire-fighters in the Building Damaged by a Fire by Using Fire-resistant Design Theories - Mainly about Suggesting the Process and the Method for a Real-time Safety Evaluation by a Fire-fighter - (화재손상 건축 구조물에서 내화설계 이론을 활용한 소방관 안전확보 방안에 관한 연구 - 소방관에 의한 실시간 안전성평가 절차 및 방법의 제안을 중심으로 -)

  • Kwon, Yeongbae;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.86-95
    • /
    • 2016
  • Weight-bearing building materials are substantially weakened under high temperatures, and this is evident through the collapse of structures once engulfed by fire. Currently, there is no scientific or technological process of evaluating the real-time structural stability of a building whcih is engulfed by flame. There are many building design specifications which aim to reduce the risk of fire, but little consideration given to fire officer safety while operating in a dangerous building. This paper aims to provide direction within building policy in order to ensure the safe evacuation of fire-fighters in case of an impending building collapse. This paper suggests evaluation criteria for buildings which are damaged due to fire, autilizing current information on fire-resistant building design and a fire-resistant capacity.

Development of VR Fire-extinguishing Experience Education Contents Using UX Design Methodology (UX 디자인 방법론을 적용한 VR 소방체험 교육콘텐츠 개발)

  • Chung, Yoo-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.3
    • /
    • pp.222-230
    • /
    • 2017
  • The Ministry of Public Safety and Security plans to expand fire safety education infrastructure to provide customized fire safety education, spread fire safety culture and develop a tailored fire safety education system as a part of the 2016 Citizens' Safety Improvement Policy. This study has also been designed to improve safety problems in the Republic of Korea. Even though safety education has been given, citizens aren't still able to experience a close-to-real situation. In addition, their understanding and satisfaction with the curriculum are very low. Therefore, this study offers VR fire-extinguishing experience education contents as an effective alternative. With a goal of having the participants experience fire extinguishing and evacuation drill in a virtual space, this program has the following advantages: i) safe fire-extinguishing experience; ii) UI to create fun ; iii) useful in fire-extinguishing education; iv) budget saving. we configure the VR fire experience system structure and hardware by applying UX design methodology. We also develop for VR-specific motion recognition plug-in and controller that can be feeling in HMD environment.

A Study on Fire Problems and Preventive Measures in Construction Sites (건축현장의 화재 문제점 분석 및 대응방안에 관한 연구)

  • Oh, Young-taek;Kang, Kyung-sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.11-24
    • /
    • 2017
  • This study attempted to establish fire risk factors and preventive measures for each of five major types of construction, focusing on construction sites. For this purpose, disaster cases were analyzed and countermeasures were prepared. In addition, fire risk factors and flammable and combustible materials by construction type according to construction process were identified and preventive measures thereof were suggested. The results of this study can be used to establish policy improvement directions that meet various educational needs and expectations by identifying the use status of flammable and combustible materials and figuring out the fire risk factors according to the process by work type in construction sites.

Fire Service Policy Theory for Establishing Fire Science (소방학의 학문적 정체성 확립을 위한 소방정책론 정립방안)

  • Ryu, Sang-Il;Lee, Jae-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.421-432
    • /
    • 2010
  • In Korea, about 80 academic departments related to fire science are in operation throughout the country, but fire science is not included as a branch science in the science classification system acknowledged by the Ministry of Education, Science and Technology and its position as a science is not solid yet. In response to this problem, research is being made actively to establish fire science recently. This study aims at composing the fire service policy theory which is one of sub areas of fire science. First, the concept of fire service policy should be established, and fire service policies should be divided into different types. In addition, it is necessary to examine the direction of the development of fire service policies in Korea, and the unique characteristics of fire service policies should be described. Next, we will mention fire service policy making and participants, theories on the determinants of fire service policies, the execution of fire service policies, and the evaluation of fire service policies. Particularly, based on the peculiarity of fire service, it is necessary to explain policies on fire prevention and precaution, fire investigation, rescue and first aid, public campaigns for safety and prevention, fire insurance, etc. Finally, we suggest the future directions of fire service policies according to the change of environment in the future.

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

지진화재사례로 본 국내 도시지역의 안전대책 연구

  • 윤명오;김광일;이영재
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.3-12
    • /
    • 1996
  • This is a paper to figure out characteristics and damages of earthquake fire occurred in Kobe, Japan by analyzing the various damage cases. The policy implications were considered in terms of safety in metropolitan areas in Korea.

  • PDF

Analysis of Spatial Characteristics of Old Building Districts in Daegu to Evaluate Fire Risk Factors (화재위험요소의 도출을 위한 대구지역 노후건축지구의 공간특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.202-203
    • /
    • 2021
  • The proportion of old buildings over 30 years old increased from 29.0% in 2005 to 37.8% in 2019. These old buildings were created during the absence of building-related safety standards such as fire safety performance. In the process of use, illegal changes and extensions were made, making them more vulnerable to safety. In the 1st Basic Plan for Fire Safety Policy, among the 12-Key Tasks, one is to ensure the safety of residential living spaces. Fire safety investigations are being conducted to prevent large-scale disasters such as multi-use buildings, but no investigation has been conducted at the regional district level where small-scale old buildings are concentrated. Therefore, in order to derive fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed.

  • PDF

Globalization Development Plans of the Convergence Systems and Policies for Domestic Fire Industry (국내 소방산업의 글로벌화 융합형 제도와 정책의 발전방안)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.55-61
    • /
    • 2015
  • This study is related with globalization development plans of the convergence systems and policies for domestic fire industry. The current issues are analysed from the condition of the policy enforcement of fire industry promotion and analysis results of the fire industry's environment. Consequently, advanced plans of promotion law and overseas expansion plans for fire industry is proposed, Especially, overseas expansion plans include technology policy strategies and activate plans of overseas expansion support for fire industry. Plans of overseas expansion support for fire industry are discussed in terms of three detailed plans including with diversification of foreign exhibitions support of fire industry, dispatch expansion of overseas market pioneer and expansion of the asian emerging markets. Especially, plans of expansion of the asian emerging markets will lead the strategic performances including with establishment of superiority in domestic fire system, provision of infrastructure abroad in domestic fire industry and of Induction of establishment in domestic fire inspection systems.

The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis (방화문의 누설틈새 계산 및 연돌효과 분석)

  • Kim, Il-Young;Kwon, Chang-Hee
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.46-53
    • /
    • 2013
  • The architecture environment has changed. The corresponding design criteria should be changed. From July 27th, 2005 the Korea Standard of the fire door changed concerning the smoke resistance test which made the door gap structure more elaborate. However the National Fire Safety Codes are applied by the old data's of England. Which in case differs in the actual construction to the blue print, making the safety standard too excessive. Analyze the results and the phenomenon that occurs due to the difference between design and reality. The National Fire Safety Codes should be revised to leakage crack calculation is presented. Difference of the air flow for the smoke protection due to the stack effect analyzed. Living patterns and evacuation patterns of the apartment reflect and reasonable air flow measurement method are presented.