• Title/Summary/Keyword: Fire Expansion

Search Result 188, Processing Time 0.034 seconds

Globalization Development Plans of the Convergence Systems and Policies for Domestic Fire Industry (국내 소방산업의 글로벌화 융합형 제도와 정책의 발전방안)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.55-61
    • /
    • 2015
  • This study is related with globalization development plans of the convergence systems and policies for domestic fire industry. The current issues are analysed from the condition of the policy enforcement of fire industry promotion and analysis results of the fire industry's environment. Consequently, advanced plans of promotion law and overseas expansion plans for fire industry is proposed, Especially, overseas expansion plans include technology policy strategies and activate plans of overseas expansion support for fire industry. Plans of overseas expansion support for fire industry are discussed in terms of three detailed plans including with diversification of foreign exhibitions support of fire industry, dispatch expansion of overseas market pioneer and expansion of the asian emerging markets. Especially, plans of expansion of the asian emerging markets will lead the strategic performances including with establishment of superiority in domestic fire system, provision of infrastructure abroad in domestic fire industry and of Induction of establishment in domestic fire inspection systems.

An Investigation on the Existing Literature to Prevent Fire Spread of High-rise Buildings (고층 건축물의 화재확대방지를 위한 기존 문헌 조사)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.102-103
    • /
    • 2021
  • In Korea, starting with the Busan residential-commercial fire in 2010, the frequency of fire expansion in high-rise buildings has been continuously increasing. In the case of such large-scale fires, most of the fires generated from the inside tend to expand to the upper floors by riding the exterior material or exterior wall panels through the process of being ejected to the outside. It has been revised so that combustible exterior materials cannot be used in buildings. However, due to the legal fluoride level, the fire risk of high-rise buildings is still high, such as the case of a 33-story residential-commercial fire in Ulsan. In order to prevent such fire expansion, it is considered that it is necessary to first understand the nature of the fire occurring inside and the mechanism of the fire expansion in the upper floor. The purpose of this study is to propose improvements in domestic fire safety design through a review of existing literature to prevent fire expansion of high-rise buildings.

  • PDF

A Study on the Application Medium Expansion Foam Extinguisher by a Fire Performance Analysis used Medium Expention Foam Agent (중발포 소화약제 소화성능 분석을 통한 중발포기 적용에 관한 연구)

  • Lee, Jang Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.402-408
    • /
    • 2019
  • Purpose: The study want to verify application the medium expantion foam extinguisher of expantion foam rate and fire extinguishing Performance test because the medium expansion system can maintain the discharge distance less affected by air currents, and the foam agent can be used efficiently. Method: For the study, the medium-expansion testing apparatus was manufactured and with synthetic surfactant foam agent of (class B) fire extinguishing model, and Fire Performance was analyzed for foam expansion rate and the fire agent consumption was measured and analyzed. Results: We measured the medium-spray testing apparatus and found that the expansion rate was 26.1 times. The test results of a 20-unit fire extinguishing model show that the extinguishing time is faster than the high and low foam expansion. It has been analyzed that it is possible to apply a hand-operated with a hose reel or medium expansion apparatus. Conclusion: Considering that the foaming agent and the extinguishing performance of the medium foam ratio are excellent, It is necessary to introduce the technical standards of medium foam agent for the introduction of hand-operated equipment, such as hose reel or portable medium foam apparatus.

Thermal Characteristics of Fire-Protection Foams Exposed to Radiant Heating (복사열에 노출된 소방용 폼 약제의 열적 특성 연구)

  • Kim, H.S.;Hwang, I.J.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1570-1575
    • /
    • 2004
  • In order to evaluate the performance of fire-fighting agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams are experimentally investigated. The current research focuses on the destruction of a fire-fighting foam subjected to heat radiation. A simple repeatable test for fire-protection foams subjected to fire radiation is developed. This test involves foam generation equipment, a fire source for heat generation, repeatable test procedures, and data acquisition techniques. Results of the experimental procedure indicated that each thermocouple within the foam responded in a similar manner and gradually to a temperature of $15^{\circ}C{\sim}20^{\circ}C$. At this point, each trace generally rises to a temperature of approximately $90^{\circ}C$. The temperature gradient in the foam as time passes increases with increased foam expansion ratio. In addition, it is determined that the temperature gradient along the foam for depth decreases with increased foam expansion ratio.

  • PDF

Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate (친환경 고발포 소화약제 개발 및 성능 분석 연구)

  • Kim, Ha-Young;Nam, Jun-Seok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.

The Plan of Funds Expansion for Fire Services to Fix Safe Environment (안전문화정착을 위한 소방재원 확충방안)

  • Choi, Nag-Soon
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.83-97
    • /
    • 2006
  • Recently, it is imperatively necessary to expand fire services funds for providing high quality of fire services. This study is to propose the plan of funds expansion for fire services to cope with a hefty increase of fire services demands in a local autonomous entity era. As alternatives of funds expansion, the study suggests the increase of fire public facilities tax rate and extracting new funds by establishing local government firms such as fire hospitals and fire repair firms. In addition, the study also proposes establishing a new common fire facilities tax, imposing fire services tax on gas tax, imposing public facilities tax on electricity tax, and transferring fire services expense to a local autonomous entity.

Thermal expansion and Shrinkage of concrete and Steel bar (고층에서의 콘크리트와 철근의 팽창 및 수축)

  • 오창희;김화중
    • Fire Science and Engineering
    • /
    • v.2 no.1
    • /
    • pp.11-20
    • /
    • 1988
  • The success of analyzing the behavior of reinforced concrete structures at elevated temperature greatly depends on how accurately certain thermal properties, especially thermal expansion, specific heat and density thermal conductivity can be determined in a wide temperature range. In this Paper, in order to Predict the behavior of reinforced concrete structure in fire hazards thermal expansion characteristics of normal concrete are formulated through experimental investigation.

  • PDF

Trends of Onboard Fire Extinguishing System (선박용 소화설비의 국제동향)

  • Kim, Mann-Eung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.126-127
    • /
    • 2005
  • This paper provides information on the current issues and the progress of on-going researches relating onboard fixed fire extinguishing system in the IMO Sub-committee on Fire Protection. And also prepares to introduce the recent amendment to regulations and technical trends of the water mist fire extinguishing system and high expansion foam system.

  • PDF

Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle (폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구)

  • Kim, Hong-Sik;Kim, Youn-Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

The Development of Fire Test Facility using the Numerical Analysis (차량 화재시험장치 설계를 위한 수치해석적 연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.919-922
    • /
    • 2008
  • The objective of this study is to design the full-scale fire test facility of the railroad vehicle with CFD simulation. In the results, the step expansion system should be good enough for the measuring system. Uniform flow is achieved at eight-to-ten diameters of the expanded duct behind the step for moderate expansion ratios($D_{orifice}/D_{duct}$ = 2 being a good choice). To optimization of the fire products collector system with 5 dampers, the additional CFD simulation was also carried out. These results will be help for the railroad fire safety research.

  • PDF