• Title/Summary/Keyword: Fire Control

Search Result 1,375, Processing Time 0.022 seconds

A Study on the Combustion Characteristics of Biomass using Cone- calorimeter (I) : the Case of Maple Leaves, Gingko Leaves, Bush, Pine Needles (콘 칼로리미터를 이용한 바이오매스의 연소특성에 관한 연구(I) - 단풍잎, 은행잎, 덤불, 솔잎에 대해서 -)

  • Park, Byung-Hyun;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Lee, Cheul-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.459-469
    • /
    • 2005
  • In recent years, concerns have been growing globally regarding greenhouse gases. Open burning of biomass causes emission of a number of greenhouse and other gases and substances. This paper studied an analysis on the characteristics of four types of biomass using duel type cone calorimeter. Cone calorimeter is widely used for assessing combustibility of materials in Europe. As a result, we evaluated several characteristics of biomass, such as heat released rate, smoke production rate, CO, $CO_2$ production and mass loss rate, and so on. $CO_2$ is currently responsible for over $60\%$ of the enhanced greenhouse effect, and may be the most important contributor to future. $CO_2$ production for biomass in the range of $1.74\~1.99kg/kg$ is similar to previous research conducted by Bhattacharya et al. (2002a).

Combustion characteristics of rice-husk according to the change of heat flux (왕겨의 heat flux별 연소특성에 관한 연구)

  • Park Eun-young;Park Duckshin;Cho Youngmin;Park Byunghyun;Lee Cheulkyu
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1190-1195
    • /
    • 2005
  • Biomass burning is a source of greenhouse gases, carbon dioxide, methane, and nitrous oxide. Under the ideal conditions of complete combustion, the burning of biomass produces carbon dioxide and water vapor. Since complete combustion is not achieved under any conditions of biomass burning, other carbon species, including carbon monoxide, methane, non-methane hydrocarbons and particulate carbon are produced. In this study, we analyze the combustion characteristics of rice-husk, such as heat release rate, smoke production rate, the percentage variation of CO and $CO_2$, oxygen consumption rate, and mass loss under different heat fluxes (20, 50 and 70kW). As a result, at 20kW incomplete combustion is occurred so that the percentage of CO is high in initial burning and total smoke release is higher than the others. At 50kW and 70kW, the combustion behaviors is very similar except the variation of CO percentage.

  • PDF

An Investigation on Fire Resistance Design of Tunnel Structures (주요 터널화재 사고사례 분석 및 국내 터널구조물 내화설계법 고찰)

  • Han, Sang-Hoon;Kim, Min-Suk;Lee, Choul-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.341-344
    • /
    • 2008
  • By investigating a series of catastrophic tunnel fires, this research aims to evaluate the fire resistance design method as applied to tunnel structures in Korea. It is shown that the current strategy is oriented towards smoke control and ventilation to reduce the loss of life. As structural collapse is not regarded, a general guide is proposed to obtain the fire safety.

  • PDF

The Effects of Firefighters' Experience of Trauma and Forest Walks on Burnout (소방공무원의 외상사건 경험 및 산림산책이 소진에 미치는 영향)

  • Shin, Sun-Hee;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.57-71
    • /
    • 2020
  • The purpose of this study is to explore the effects of fire officers' experience of traumatic events and subsequent forest healing on their occupational burnout. The results are as follows: First, the experience of traumatic events, social and psychological healing, and relieving stress by strolling had a significant effect on burnout. The more fire officers are exposed to traumatic events, the more they lose self-control in social and psychological aspects, and the lower the level of stress relieved through strolling, the higher the level of burnout. Thi sresult suggests that the more fire office rsare called out for fire fighting, the more they see their colleagues with severein juries, and the higher the level of mental and physical an xiety, the more they areex hausted. Moreover, for es thealing help store duce the irmental and physi calfatig uecaused by traumatic events, thu spreven ting them from suffering from burn out. Second, the experience of traumatic events, social and psychological healing, and relieving stress by strolling had a significant impact on occupational stress. The more fire officers are exposed to traumatic events, the more they lose self-control in social and psychological aspects, and the lower the level of stress relieved through strolling, the higher the level of occupational stress. This result indicates that to relieve job stress caused by fire fighting, increased forest healing activities, including various programs such as psychotherapy, developing interpersonal relationships and self-control, and creating a positive mind-set, can reducejobstress and help fire officers recover from it. Lastly, job stress had a mediation effect on the effects of the experience of traumatic events and forest healing on burnout. This implies that burnout can be prevented when fire officers gain high emotional stability through social and psychological healing and stress-relief strolling over a traumatic experience, and stronger support from the organization and family can keep them from being emotionally drained, thus contributing to the prevention of burnout.

Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force (제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.24-30
    • /
    • 2012
  • The purpose of this study is to analyze the problem in measuring the differential pressure between the fire area and the neighboring smoke control zone as well as the opening force of a fire door and to present the actual values measured by an objective method. NFSC 501A specifies that the force necessary to open an access door when operating a smoke control system shall be less than 110 N. When the smoke control system does not operate in the space where it is installed, the door opening force can be measured by the test method in KS F 2805. However, when the smoke control system operates, additional opening force is required to overcome the force generated by the differential pressure between the fire area and smoke control room. Therefore, it can be seen that the method proposed by the standard has insufficient reliability. The analog measuring device and digital measuring device showed that the opening forces, $F_a$ and $F_d$, of the fully closed door before the smoke control system were 27.8 N and 27.4 N, respectively. When the door remained open by $5^{\circ}$, the opening forces, $F_a$ and $F_d$, were 33 N and 33.6 N, respectively. When the smoke control system operated and the door was fully closed, the door opening forces, $F_a$ and $F_d$, were 77.6 N and 76.0 N, respectively. Therefore, since the door opening forces are different from the criteria presented by KS F 2805, it is required to review the criteria appropriately.

The investigation of erosion control works' condition in East sea fire area (동해안 대형 산불피해지의 사방사업 실태진단)

  • Yeom, Kyu-Jin;Chun, Kun-Woo;Cha, Doo-Song;Lee, Si-Young;Lee, Hyun-Kyu;Lee, Myung-Woog;Kim, Youn-Jin;Lee, Jin-Ho;Kim, Suk-Woo;Tsugio, Ezaki
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.509-512
    • /
    • 2007
  • The fire area need management to prevent enlargement of collapes and sinkage. and it need that repair Vegetation sack work, Soil arresting structure, Terrace-sodding works, Direct seeding works in greening works and Water cushion in erosion control dam. The whole of the Concrete stream grade stabilization structures were broken, it need to be repair. As pass the time, a lot of structures were abandoned. Therefore, it need to reorganize erosion control structures and the method of construction in the fire area

  • PDF

The Development of Virtual Fire Control System Considering Operational Environment of Helicopter (헬기 운용환경을 고려한 가상 사격 통제 시스템 개발)

  • Kim, Woosik;Lee, Dongho;Jang, Indong;Park, Hanjoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.448-455
    • /
    • 2014
  • Virtual Fire Control System(VFCS) in attack helicopter is developed. VFCS is comprised of multifunction display, store management computer, mission computer, target acquisition and designation system, mission planning system, weapon simulator and flight simulator. Weapon engagement process under the operational environment of helicopter was considered by using the VFCS. We considered hellfire missile, tow missile, unguided rocket and turret gun. The results of this study will be utilized efficiently on integrated fire control system SIL(System Integration Lab.) in attack helicopter.

Study on Analyzing and Correction of Dynamic Battery Alignment Error in Naval Gun Fire Control System by using Image of Boresight Telescope (포배열카메라 영상을 활용한 함포 사격통제시스템의 동적배열오차 분석 및 보정방법)

  • Kim, Eui-Jin;Suh, Tae Il
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.745-751
    • /
    • 2013
  • In naval gun firing, firing accuracy comes from the combination of each component's accuracy in CFCS (Command and Fire Control System) like tracking sensors and gun. Generally, battery alignment is done to correct the error between gun and tracking sensor by using boresight telescope on harbor and sea. But normally, the battery alignment can compensate only the static alignment error and ignore dynamic alignment error which is caused by own ship movement. There was no research on this dynamic alignment error until now. We propose a new way to analyze dynamic arrangement error by using image of boresight telescope. In case of the dynamic alignment error was due to time delay of own ship attitude information, we propose the way to compensate it.

A Study on the Conditions of Injection Pressurization in the Smoke-Control Zone II. Analysis of the Conditions for Closing Force of Fire Door with Variation of Angular Velocity (제연구역 방화문의 각속도 변화와 폐쇄 조건 분석)

  • Lee, Chang-Wook;Kim, Hong-Jin;Choi, Young-Ki;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.6-10
    • /
    • 2013
  • This study aims to construct the performance data for smoke-control zone and realize the safety of injection and pressurization room which is composed of supply air pressure zone, vestibule, smoke-control zone and stairwell. To obtain this, smoke-control system and the device of the opening-closing force of fire door are manufactured. This subject is the analysis of the closing force, angular velocity and fire door size in the case of fixed volume flow rate. Based on the results, closing force increased as fire door size and closing angular velocity increases. Also, it is remark that there exists a critical angular velocity, which maintains constant maximum closing force even though the angular velocity increases more.