High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가 (Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT))

  • 김진수;이재성;이병일;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.318-324
    • /
    • 2004
  • 목적: Philips GEMINI PET/CT 스캐너는 GSO 섬광결정을 사용해 제작된 전신용 PET/CT 스캐너이다. 이 연구에서는 NEMA에서 새롭게 제안한 NEMA NU2-2001에 따라 GEMINI PET/CT 스캐너의 공간분해능, 민감도, 산란분획, NECR 등을 평가하고 그 결과를 BGO, LSO등의 섬광결정의 특성과 비교하였다. 대상 및 방법: GEMINI는 Philips ALLEGRO PET과 MX8000 D multi-slice CT 스캐너를 결합한 PET/CT 스캐너로서 검출기는 GSO 섬광결정 ($4{\times}6{\times}20mm^3$)을 사용하였고 축방향 시야는 18 cm이다. 공간분해능. 민감도, 산란분획, NECR 등을 평가하기 위하여 PET 데이터를 획득하였다(동시계수창: 8 ns, 에너지창: $409{\sim}664$ keV). 공간분해능 측정을 위하여 축횡단면의 중심에서 1 cm, 10 cm 떨어진 지점의 각 3지점((a) x=0, y=1, (b)x=10, y=0, (c)x=0, y=10)에서 영상을 획득한 다음 여과후역투사방법(램프필터 사용)과 3D RAMLA를 이용하여 영상재구성을 하고 FWHM을 구하였다. 민감도 측정을 위하여 선선원(F-18)을 축횡단면의 중심과 중심에서 10 cm 벗어난 지점에서 5개의 알루미늄관을 차례로 씌워 매질감쇠에 따라 달라지는 참계수를 구하고 이 값을 회귀분석하여 감쇠매질이 없는 이상적인 상황에서의 민감도를 측정하였다(랜덤계수가 참계수의 1%이내). 산란분획과 NECR을 측정하기 위하여 F-18 선선원(1110 MBq)을 산란팬텀에 주입하여 7반감기동안 계수를 획득하였다. SSRB을 사용하여 3D 데이터를 재구성한 다음 랜덤계수율이 참계수율이 1% 미만인 영역에서 산란분획을 구하고 각 횡단면의 값을 평균하여 전체 산란분획을 얻었다. 이 값을 기초로 각 프레임, 각 횡단면에 대한 랜덤계수율, 산란계수율, NECR을 구하였다. 결과: 스캐너의 중심에서 1 cm 벗어난 지점에서 횡축방향, 축방향 공간분해능은 (1) 5.3, 6.5 mm (FBP), (2) 5.1, 5.9 mm (3D RAMLA)이었다. 횡단면의 중심에서 10 cm 벗어난 지점에서 횡축반경방향, 횡축접선방향, 축방향 공간분해능은 (1) 5.7, 5.7, 7.0 mm (FBP), (2) 5.4, 5.4, 6.4 mm (3D RAMLA)이었다. 감쇠매질이 없는 이상적인 상황에서의 민감도는 횡단면의 중심에서 3,620 counts/sec/MBq, 횡단면의 중심에서 10 cm 벗어난 지점에서 4,324 counts/sec/MBq이었다. 산란분획은 40.6%, 최대 참계수율과 최대 NECR은 각각 88.9 kcps @ 12.9 kBq/mL, 34.3 kcps @ 8.84 kBq/mL이었다. 결론: 이 실험에서 NEMA NU2-2001을 이용해 GSO 섬광결정을 사용해 제작된 PET/CT에 대한 성능 평가를 실시하였다. 이는 BGO, LSO 섬광결정을 사용해 제작된 PET 스캐너의 특성과 비교할 수 있는 자료를 제공하며 PET 영상 획득 시 객관적 평가와 분석에 유용하였다.

요트 발전을 위한 한국형 마리나 운영방안에 관한 연구 (The research for the yachting development of Korean Marina operation plans)

  • 정종석;허일
    • 한국항해항만학회지
    • /
    • 제28권10호
    • /
    • pp.899-908
    • /
    • 2004
  • 소득수준의 향상과 주 5일 근무제에 따른 여가활용 시간의 증대에 수반하여 해양 선진국처럼 많은 사람들이 요트 활동을 원하고 있는 동시에 수많은 장비들의 보급이 확산되고 있다. 이러한 장비의 보급발전에 수반하여 활동영역도 넓어지고 있지만 요트를 즐길 수 있는 마리나의 환경조성은 경제 후진국보다 더욱 낙후되어 있는 실정이다. 이렇게 낙후된 한국의 요트 발전을 위하여 선진 마리나 운영의 모형을 한국의 실정에 맞게 적용할 필요성이 있어 마리나를 성공적으로 운영하고 있는 호주, 뉴질랜드, 싱가포르, 일본, 말레이시아의 마리나 운영적 국면을 상호 비교 분석하여 다음과 같은 결론을 얻었다. 첫째, 마리나 운영에 있어서 개인의 재산권 보호 및 환경보존 측면에서 회원제, 비회원제, 영리, 비영리로 분리 운영하되 클럽하우스 출입시 복장은 통제하지 않아야 한다. 둘째, 부가가치를 높이기 위하여 매년 새로운 경기이벤트를 유치하고 경기운영에 있어서 자원봉사자를 적극 활용하여야 하며, 요트를 통하여 관광을 활성화하고, 외국요트 입출항시 CIQ 절차를 간소화함은 물론 언어서비스도 병용하여야 한다. 셋째, 연중 상설요트학교를 개설하고 지도자 자격을 갖춘 강사가 지도하되, 초급반, 중급반, 고급반으로 분리 운영하고 어린이용 딩기요트 프로그램을 중요하게 운영하여야 한다. 넷째, 계류장 입${\cdot}$출항 통제는 자율에 의해서 통제하고 계류장 사용료 납부 후 보안감시 및 장비의 분실, 파손에 대하여 마리나 측에서 일정한 보상을 할 수 있도록 제도적으로 보완하여야 한다. 다섯째, 한국의 실정에 맞게 해상안전요원을 민간단체로 구성하여 벤치마크, 인명구조, 해난사고시 해상수색 등에 적극 활용하여야 한다.사에 대한 평균 수평응력비의 적용이 고려되어져야 할 것으로 판단된다.로 구매를 하기도 하였으며, 신용카드를 소비에만 사용하는 경향이 있는 사람은 패션지향적이거나 순수한 충동에 의한 구매행동을 하는 것으로 나타났다. 본 연구는 한국과 미국의 국가간 비교연구로 대학생들의 충동구매행동과 신용카드사용에서 국가간 유사성과 차이가 있음을 밝혀줌으로써 국내외 마케터들에게 유용한 정보를 제공해 준다.적 비교에 대한 통계적 타당성의 기초를 마련하였다는데 의의가 있다.가지고 있는 지 확인하기 위해 사람 방광 유래의 T-24세포와 장내 표피 유래의 Caco-2세포에 대한 부착능을 시험하였을 때, 16균주$(42.1\%)$가 T-24방광 세포에, 그리고 17균주$(44.7\%)$가 Caco-2장세포에 대해 강한 부착능을 나타내었다. 특히 11균주$(28.9\%)$는 두 세포 모두에 강한 부착능을 가지고 있었다. Filter mating method를 수행하여 이들 균주들의 독소 생산 유전자와 항생제 내성 유전자가 사람에서 분리된 균주로 전달되는 것을 확인할 수 있었다. 본 실험의 결과는 설사 중상을 나타내는 돼지로부터 분리된 용혈성 E. coli의 독성과 세포 부착능력, 그리고 항생제 내성간의 상호 연관성을 보여주지 않았으나 동물 분리 세균의 항생제 내성과 독소 생산 능력이 유전자 전달을 통해서 뿐만 아니라 세균의 직접 접촉에 의해서도 인체로 전달될 수 있는 것을 보여주는 것이다.다. 본 연구를 토대로 장시간의 체외순환에서는 신장기능을 대표하는 수치들에도 영향을 미칠 수 있으리라 예상되며, 신장 이외에 다른 주요 장기에 미치는 영향에 대한 연구를 더 진행할 필요가

1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성 (The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT)

  • 최진욱;김수미;이형진;김진의;김현주;이재성;이동수
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.94-100
    • /
    • 2011
  • 1-day protocol method는 DIAMOX 영상에서 basal 영상을 감산시키는 방법으로 혈관 예비능을 평가하는데 있어서 매우 유용한 검사지만, 검사시간이 길기 때문에 움직임에 의한 불가피한 재검사율이 높다. 기하학적으로 차이가 있는 fan-beam 콜리메이터와 parallel 콜리메이터 중 임상적으로 1-day protocol method에 가장 효율적인 콜리메이터가 무엇인지 알아보았다. 삼중 헤드 감마카메라인 triad XLT 9 (TRIONIX)와 세 가지 콜리메이터(low energy high resolution-parallel beam: LEHR-par, ultra resolution-fan beam: LEUR-fan, super fine-fan beam: LESR-fan)를 사용하였다. PET/SPECT performance phantom, Hoffman 3D phantom, volunteer 실험을 실시하여 세 가지 콜리메이터의 감도, 대조도, 해상력, 영상의 질을 비교 측정하였다. Pixel size를 fan-beam 콜리메이터와 동일하게 하기 위하여 parallel 콜리메이터 실험 시 zoom factor를 2.0으로 변경하였다. Scan time은 50 kcounts/frame을 만족하게 하였으며 filtered back projection (FBP)의 재구성 방법을 사용하였고 각 콜리메이터 별 최적의 영상을 위하여 cut off 값을 변화하면서 비교 측정하였다. 총 획득 계수가 동일한 조건에서 해상력과 percent background variability는 LESR과 LEUR이 LEHR보다 우수한 결과를 나타내었고, 영상의 육안평가에서 선호도는 LESR, LEUR, LEHR 순이었다. 영상 획득 시간은 LESR이 낮은 감도로 인하여 LEUR과 LEHR보다 약 2배 더 길게 소요됐다. Volunteer 실험의 결과 LESR을 사용할 때보다 LEUR 또는 LEHR을 사용 할 때 약 10-14분 정도 시간이 감소했다. 1-day protocol method는 단 한 번의 움직임에도 재검사가 불가피하기 때문에 적절한 분해능뿐만 아니라 높은 감도의 유지를 위해 적절한 검사 방법의 확립이 중요하다 할 수 있다. 본 연구에서 동일한 계수를 획득할 경우 LEUR은 LESR보다 2배의 시간을 감소시킬 수 있었고 영상의 육안평가나 해상력도 LESR과 임상적으로 큰 차이를 보이지 않았으므로 Brain SPECT의 1-day protocol method에 가장 적합할 것으로 사료된다.

  • PDF

목조문화재의 보존을 위한 한국산 흰개미의 생태적 특성 연구 (Ecological Characteristics of Termite(Reticulitermes speratus kyushuensis) for Preservation of Wooden Cultural Heritage)

  • 이규식;정소영
    • 헤리티지:역사와 과학
    • /
    • 제37권
    • /
    • pp.327-348
    • /
    • 2004
  • 본 연구에서는 한반도 이남의 지역적 기후 특성을 분석하고, 서식하고 있는 흰개미 (Reticulitermes speratus kyushuensis Morimoto)의 생태적 특성 및 선호도(온도, 습도, 수종)를 실험실에서 확인하였다. 한반도 이남, 특히 남부지역은 흰개미(R. speratus kyushuensis Morimoto)의 서식 및 활동에 최적인 기후지역으로 확인되었다. 부산이 Coptotermes formosanus Shiraki의 야외 분포 북방한계 ($4^{\circ}C$)에 근접되어 있고, 춘천이 Reticulitermes speratus Kolbe의 야외분포 북방한계 ($-4^{\circ}C$)가 한반도를 통과하는 지역으로 확인되었다. 흰개미는 $30^{\circ}C$ (90% RH이상)에서 최대 먹이 섭취율을 보였다. $10^{\circ}C$에서 $30^{\circ}C$(90% RH 이상)까지 약 95%이상의 생존율이 관찰되었지만, $32^{\circ}C$이상에서 사망률이 높아졌다. 또한 52% RH($30^{\circ}C$)와 70% RH($30^{\circ}C$)에서 높은 사망률(100%)이 관찰되었지만 84% RH에서 높은 생존율(97%)을 보였다. 침엽수인 소나무를 먹이로 선호하고 높은 생존율(87%)을 보였지 만 활엽수인 오동나무에서는 낮은 생존율(14%)이 확인되었다. 서울 종묘의 자연수림에서 흰개미의 침입율은 약 34.5%(55개 지점 중 19개 지점, 3년간) 이었다. 침입율은 매년 증가하였지만 발견율은 낮아지고 실종률은 높아지는 경향이 확인되었다. 흰개미 군체 일부는 발견된 목재를 계속 섭취하고, 다른 일부는 새로운 목재를 탐색하는 먹이 찾기 습성을 실험적으로 확인하였다. 종묘의 지표부근에서 흰개미를 관찰할 수 있는 기간은 2001년 4월부터 11월까지이고 최대 활동기는 7월 및 8월인 것으로 야외실험을 통하여 확인하였다. 그리고 동절기(2000년 11월~2001년 3월)에도 지중에서 활동하는 것이 확인되었다. 이상의 결과, 한국 목조문화재를 가해하는 흰개미의 생태적 특성 및 가해 정도에 관한 생물학적 기초 자료를 최초로 제시하였다. 특히 한반도 이남의 기후조건에 따른 흰개미의 활동시기 및 이에 따른 지역적 손상분포를 확인하고 이를 방제할 수 있는 목재 보존제의 성분 특성 및 효과가 확인됨에 따라 향후 생물학적 손상, 특히 흰개미로부터 한국 목조문화재를 예방적으로 보존 관리하기 위한 종합적 방안수립(Integrated Pest Management, IPM)이 가능할 것으로 기대된다. 또한 이러한 연구결과는 흰개미로 발생되는 경제적 손실을 줄일 수 있는 방제학적 기초 자료로 활용될 것으로 기대된다.

NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가 (Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001)

  • 김진수;이재성;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.259-267
    • /
    • 2004
  • 목적: 전신용 PET에 대한 표준 성능 평가 방법으로 NEMA NU2-2001이 확립되어 제안되었다. 따라서 새로이 설치되는 PET 스캐너뿐 아니라 기존에 사용 중인 스캐너에 대한 성능 평가가 이 표준 방법에 따라서 새로이 이루어 져야 한다. 이 연구에서는 NEMA NU2-2001 방법을 이용하여 CTI ECAT EXACT 47 PET 스캐너의 공간해상도, 민감도, 산란분획, NECR 등을 측정하였다. 대상 및 방법: 공간해상도를 평가하기 위하여 축 방향 시야의 정 가운데와 축 방향 시야 길이의 1/4을 벗어난 횡단면에 F-10을 채운 유리관(내경 1.1 mm)을 횡단면의 중심에서 1, 10 cm 떨어진 지점에 축 방향과 평행하게 위치시킨 후 PET 영상을 얻었다. 민감도를 측정하기 위하여 폴리에틸렌 및 알루미늄 관에 F-18을 채운 후 불응시간 손실이 1%를 넘지 않는 것을 확인한 후 영상을 획득하였다. 산란분획 및 최적 영상 획득 조건을 얻기 위하여 NECR을 NEMA 산란 팬텀을 이용하여 측정하였다. 결과: FBP재구성 방법(화소 크기: $0.515{\times}0.515mm^2$)으로 영상을 재 구성했을 때 스캐너의 중심에서 1cm 벗어난 지점에서 축방향, 횡축방향 공간 분해능은 0.62, 0.66 cm (FBP, 2D와 3D), 0.67, 0.69 cm (FBP, 2D와 3D)이었고 중심에서 10 cm 벗어난 지점에서 축방향, 횡축반경방향, 횡축접선방향 공간 분해능은 0.72, 0.68 mm (FBP, 2D와 3D), 0.63, 0.66 mm (FBP, 2D와 3D), 0.72, 0.66 mm (FBP, 2D와 3D)이었다. 민감도는 스캐너의 횡축방향 708.6 (2D), 2931.3 (3D) counts/sec/MBq, 횡축방향 중심에서 10cm 벗어난 지점에서 728.7 (2D), 3398.2 (3D) counts/sec/MBq 이었다. 산란 분획은 0.19 (2D), 0.49 (3D)이었고 최고 참 계수율과 NECR은 2차원 영상 획득 모드에서 40.1 kBq/mL 일 때 64.0 kcps, 40.1 kBq/mL 일 때 49.6 kcps, 3차원 영상 획득 모드에서 4.76 kBq/mL 일 때 53.7 kcps, 4.47 kBq/mL 일 때 26.4 kcps이었다. 결론: 이 실험에서 NEMA NU2-2001로 측정한 PET스캐너의 물리적 특성은 PET스캐너에 대한 객관적 평가 및 최적화 된 영상 획득과 분석에 유용할 것이다.