• 제목/요약/키워드: Film Location

검색결과 169건 처리시간 0.031초

PET film에서 Artificial Void 의 크기에 따른 PD 패턴 분석 (A Study on the Partial Discharge Pattern according to the Artificial Void Dimensions in PET Film)

  • 최필문;정병선;이종찬;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.415-421
    • /
    • 1999
  • This paper indicate that phase resolved partial discharge patterns are investigated on PET films containing artificial void of varing dimensions. In this study, we measured phase-resolved PD patterns and statistical parameter from PET specimens with IGT(insulation/airgap/insulation) structure by IEC 270 standard. Measurement system is the conventional PD detector using digital signal processing technique. The relationship of diameter and location of artificial void was discussed through the difference of $\pi$-q-n distribution and statistical analysis.

  • PDF

Reynolds수와 난류강도의 변화에 따른 실린더 주위 유동 박리점의 거동에 관한 실험적 연구 (An experimental study of flow separation around a circular cylinder with Reynolds number and free stream turbulence intensity variations)

  • 임용섭;손동기;양경수;이준식
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.889-898
    • /
    • 1998
  • The influences of the Reynolds number and free-stream turbulence intensity on the flow separation behavior around a circular were investigated experimentally. The range of the Reynolds number and turbulence intensity considered are 10,000 ~ 45,000 and 0.3 ~ 6.8%, respectively. Because of ineffectiveness of using time-mean value of hot-film sensor signals in determining the separation location around the cylinder, a new method using phase-difference of hot-film sensor signals with hot-wire being located in shedding vortex is suggested. The validity of the present method is confirmed by the comparison with flow visualization.

피에조 필름을 이용한 평판에서의 유동유기 소음원의 능동제어 (Active Controll of Flow Noise Sources of Flat Plate Using Piezo Film)

  • 신승열;송우석;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.924-927
    • /
    • 2004
  • Measurements of fluctuating wall pressures were made with a linear array of 16 piezo-electric transducers beneath a fully-developed turbulent boundary layer. The piezoelectric bimorph actuator applied in this experiment has bonding structures of each polarity to make out-of-plane displacements rather than in-plane ones by using piezoelectric effect To specify the boundary layer characteristics at the location where the actuation was applied, the wall friction coefficients and $Re_\theta$ were measured by using the CPM method. The actuating frequency for the bimorph film was determined according to the priori bursting frequency from boundary layer parameters. The reduction of convecting energies in wave-number space was clearly observed at the specified actuating frequencies.

  • PDF

X선 촬영을 통한 노궁(勞宮)의 혈위에 대한 고찰 (Measuring the Location of PC8 Acupuncture Point Using X-ray Radiography in Healthy Adults)

  • 구성태;김성철;김용석;강성길;최선미
    • 한국한의학연구원논문집
    • /
    • 제16권3호
    • /
    • pp.123-126
    • /
    • 2010
  • Objective : There are controversial opinions on the location of PC8 (Nogung). The one is to localize the point between the 2nd and 3rd metacarpal bone, the other is to localize the point between the 3rd and 4th metacarpal bone. The study was performed to provide an experimental evidence to standardize the location of PC8 point. Methods : We employed 30 healthy adults evenly in sex. To identify the location of PC8 in the hand, we took X-ray photograph in both hands of participants. Thin layer of leads were pasted on to PC7 and tip of middle finger prior to take X-ray photograph. The line connecting two points corresponding to the leads in X-ray film was read by a radiologist to decide that the line passes which side between the 2nd metacarpal space and the 3rd one. Results and Conclusions: The line passed the 3rd metacarpal space in 49 cases out of 60 hands (82 %). Data suggest that PC8 could be localized at the point between the 3rd and 4th metacarpal bone.

자기유변유체를 이용한 반능동형 스퀴즈 필름 댐퍼의 해석 및 회전체 불균형 응답 제어 (Analysis of Magneto-rheological Fluid Based Semi-active Squeeze Film Damper and its Application to Unbalance Response Control of Rotor)

  • 김근주;이종원
    • 한국소음진동공학회논문집
    • /
    • 제15권3호
    • /
    • pp.354-363
    • /
    • 2005
  • Squeeze film dampers (SFDs) have been commonly used to effectively enhance the dynamic behavior of the rotating shaft supported by rolling element bearings. However, due to the recent trends of high operating speed, high load capacity and light weight in rotating machinery, it is becoming increasingly important to change the dynamic characteristics of rotating machines in operation so that the excessive vibrations, which may occurparticularly when passing through critical speeds or unstable regions, can be avoided. Semi-active type SFDs using magneto-rheological fluid (MR fluid), which responds to an applied magnetic field with a change in rheological behavior, are introduced in order to find its applications to rotating machinery as an effective device attenuating unbalance responses. In this paper, a semi-active SFD using MR fluid is designed, tested, and identified to investigate the capability of changing its dynamic properties such as damping and stiffness.In order to apply the MR-SFD to the vibration attenuation of a rotor, a systematic approach for determining the damper's optimal location is investigated, and also, a control algorithm that could improve the unbalance response characteristics of a flexible rotor is proposed and its control performance is validated with a numerical example.

질산염 전구체 원료로 분무 열분해 방법에 의한 YBCO 박막 증착 (Deposition of YBCO Thin Film by Aerosol Assisted Spray Pyrolysis Method using Nitrate Precursors)

  • 김병주;홍석관;김재근;이종범;이희균;홍계원
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.68-73
    • /
    • 2010
  • Y123 films have been deposited on $LaAlO_3$ (100) single-crystal and IBAD substrates by spray pyrolysis method using nitrate precursors. Ultrasonic atomization was adopted to decrease the droplet size, spraying angle and its moving velocity toward substrate for introducing the preheating tube furnace in appropriate location. A small preheating tube furnace was installed between spraying nozzle and substrate for fast drying and enhanced decomposition of precursors. C-axis oriented films were obtained on both LAO and IBAD substrates at deposition temperature of around $710{\sim}750^{\circ}C$ and working pressures of 10~15 torr. Thick c-axis epitaxial film with the thickness of $0.3{\sim}0.6\;{\mu}m$ was obtained on LAO single-crystal by 10 min deposition. But the XRD results of the film deposited on IBAD template at same deposition condition showed that the buffer layers of the IBAD metal substrate was affected by long residence of metal substrate at high temperature for YBCO deposition.

수소 및 중수소가 포함된 실리콘 산화막의 전기적 스트레스에 의한 열화특성 (Degradation of Ultra-thin SiO2 film Incorporated with Hydrogen or Deuterium Bonds during Electrical Stress)

  • 이재성;백종무;정영철;도승우;이용현
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.996-1000
    • /
    • 2005
  • Experimental results are presented for the degradation of 3 nm-thick gate oxide $(SiO_2)$ under both Negative-bias Temperature Instability (NBTI) and Hot-carrier-induced (HCI) stresses using P and NMOSFETS, The devices are annealed with hydrogen or deuterium gas at high-pressure $(1\~5\;atm.)$ to introduce higher concentration in the gate oxide. Both interface trap and oxide bulk trap are found to dominate the reliability of gate oxide during electrical stress. The degradation mechanism depends on the condition of electrical stress that could change the location of damage area in the gate oxide. It was found the trap generation in the gate oxide film is mainly related to the breakage of Si-H bonds in the interface or the bulk area. We suggest that deuterium bonds in $SiO_2$ film are effective in suppressing the generation of traps related to the energetic hot carriers.

자기유변유체를 이용한 반능동형 스퀴즈 필름 댐퍼의 해석 및 회전체 불균형 응답 제어 (Analysis of Magneto-rheological Fluid based Semi-active Squeeze Film Damper and Its Application to Unbalance Response Control of Rotor)

  • 김근주;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1005-1011
    • /
    • 2004
  • Squeeze film dampers (SFDs) have been commonly used to effectively enhance the dynamic behavior of the rotating shaft supported by rolling element bearings. However, due to the recent trends of high operating speed, high load capacity and light weight in rotating machinery, it is becoming increasingly important to change the dynamic characteristics of rotating machines in operation so that the excessive vibrations, which may occur particularly when passing through critical speeds or unstable regions, can be avoided. Semi-active type SFDs using magneto-rheological fluid (MR fluid), which responds to an applied magnetic field with a change in rheoloaical behavior, are introduced in order to find its applications to rotating machinery as an effective device attenuating unbalance responses. In this paper, a semi-active SFD using MR fluid is designed, tested and identified by means of linear analysis to investigate the capability of changing its dynamic properties such as damping and stiffness. Furthermore, the proposed device is applied to a rotor system to investigate its potential capability for vibration attenuation: an efficient method for selecting the optimal location of the proposed damper is introduced and control algorithm that could improve the unbalance response properties of a flexible rotor is also proposed.

  • PDF

X-Ray Reflectivity Analysis Incorporated with Genetic Algorithm to Analyze the Y- to X Type Transition in CdA LB Film

  • 최정우;조경상;이희우;이원홍;이한섭
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권5호
    • /
    • pp.549-553
    • /
    • 1998
  • The structure and layer distribution of cadmium arachidate Langmuir-Blodgett film were analyzed by the small angle X-ray reflectivity measurements using synchrotron radiation. Y-to X type transition was ocurred during the 39th passage of deposition of cadmium arachidate. Based on the measurement of the consumed area of the monolayer, it was determined that about 27.5 layer was deposited. Using the synchrotron X-ray, the reflectivity profile of cadmium arachidate LB film over the wide range of grazing angle was obtained. The X-ray reflectivity profile was analyzed using the recursion formula. By fitting the location and dispersion of the subsidiary maxima between the Bragg peaks of the measured reflectivity profile with that of the calculated reflectivity profile, the average thickness and the distribution of layer thickness were evaluated. The genetic algorithm was adopted to the fitting of reflectivity profile to evaluate the optimum value of the number distribution of layer. Based on the morphology measurement with an atomic force microscopy (AFM), the domain structure and mean roughness of LB films were obtained. The mean roughness value calculated based on the number of layer distribution obtained from the measurement by AFM is consistent with that obtained from X-ray reflectivity analysis.

고온 시편의 급랭 시 산화철 나노유체가 최소막비등점에 미치는 영향에 대한 실험적 연구 (Experimental Study on Effect of Water-based Iron(III) Oxide Nanofluid on Minimum Film Boiling Point During Quenching of Highly Heated Test Specimen)

  • 정찬석;황경섭;이치영
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.128-136
    • /
    • 2020
  • In the present experimental study, the effect of water-based iron(III) oxide nanofluid on the MFB(Minimum Film Boiling) point during quenching was investigated. As the highly heated test specimen, the cylindrical stainless steel rod was used, and as the test fluids, the water-based iron(III) oxide nanofluids of 0.001 and 0.01 vol% concentrations were prepared with the pure water. To examine the effect of location in the test specimen, the thermocouples were installed at the bottom and middle of wall, and center in the test specimen. Through a series of experiments, the experimental data about the influences of nanofluid concentrations, the number of repeated experiments, and locations in the test specimen on the reaching time to MFB point, MFBT(Minimum Film Boiling Temperature), and MHF(Minimum Heat Flux) were obtained. As a result, with increasing the concentration of nanofluid and the number of repeated experiments, the reaching time to MFB point was reduced, but the MFBT and MHF were increased. In addition, it was found that the effect of water-based iron(III) oxide nanofluid on the MFB point at the bottom of wall in the test specimen was observed to be greater than that at the middle of wall and center. In the present experimental ranges, as compared with the pure water, the water-based iron(III) oxide nanofluid showed that the maximum reduction of reaching time to MFB point was about 53.6%, and the maximum enhancements of MFBT and MHF were about 31.1% and 73.4%, respectively.