Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference (한국전기전자재료학회:학술대회논문집)
- 1999.05a
- /
- Pages.415-421
- /
- 1999
A Study on the Partial Discharge Pattern according to the Artificial Void Dimensions in PET Film
PET film에서 Artificial Void 의 크기에 따른 PD 패턴 분석
Abstract
This paper indicate that phase resolved partial discharge patterns are investigated on PET films containing artificial void of varing dimensions. In this study, we measured phase-resolved PD patterns and statistical parameter from PET specimens with IGT(insulation/airgap/insulation) structure by IEC 270 standard. Measurement system is the conventional PD detector using digital signal processing technique. The relationship of diameter and location of artificial void was discussed through the difference of
Keywords