• Title/Summary/Keyword: Filling time

Search Result 798, Processing Time 0.028 seconds

Analysis of RTM Process Using the Extended Finite Element Method (확장 유한 요소 법을 적용한 RTM 공정 해석)

  • Jung, Yeonhee;Kim, Seung Jo;Han, Woo-Suck
    • Composites Research
    • /
    • v.26 no.6
    • /
    • pp.363-372
    • /
    • 2013
  • Numerical simulation for Resin Transfer Molding manufacturing process is attempted by using the eXtended Finite Element Method (XFEM) combined with the level set method. XFEM allows to obtaining a good numerical precision of the pressure near the resin flow front, where its gradient is discontinuous. The enriched shape functions of XFEM are derived by using the level set values so as to correctly describe the interpolation with the resin flow front. In addition, the level set method is used to transport the resin flow front at each time step during the mold filling. The level set values are calculated by an implicit characteristic Galerkin FEM. The multi-frontal solver of IPSAP is adopted to solve the system. This work is validated by comparing the obtained results with analytic solutions. Moreover, a localization method of XFEM and level set method is proposed to increase the computing efficiency. The computation domain is reduced to the small region near the resin flow front. Therefore, the total computing time is strongly reduced by it. The efficiency test is made with a simple channel flow model. Several application examples are analyzed to demonstrate ability of this method.

Comparison of Rice Stripe Disease Occurrence and Yield under Different Rice (Oryza sativa L.) Cultivars (이앙시기에 따른 벼 품종별 줄무늬잎마름병 발생 및 수량 비교)

  • Cha, Kwang-Hong;Oh, Hwan-Jung;Park, Heung-Gyu;Jung, Woo-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.18 no.1
    • /
    • pp.75-82
    • /
    • 2010
  • The purpose of this study is to investigate an occurrence rate of rice stripe virus disease under different rice transplanting time and different rice cultivars. After final harvest, the yield of rice infected by rice stripe virus was obtained on Wangchal cultivar compared to uninfected rice. The results obtained as following: 1) Yield of rice infected by rice stripe virus was decreased by 64% with reduction of culm length, pancile length, number of spike, number of spikelet, and grain filling compared to uninfected rice, 2) An occurrence rate of rice stripe virus disease under different rice planting season was high as order of May 30 > June 15 > July 1. In additional, to reduce a rice stripe virus disease on higher disease occurrence region and susceptible cultivars, rice planting season will be accepted on and after June 15, and 3) Eighteen cultivars were resistance cultivars such as Hwayeongbyeo, Onnuri, Ilmibyeo, Nampyongbyeo, Dongjin2ho, Hopumbyeo, Hwangkeumnuri, Malgeumi, Saenuri, Pungmi1ho, Haechanmulgyeo, Hwangkeumnodeul, Chilbobyeo, Dongjinbyeo, Younganbyeo, Junambyeo, Samkwangbyeo, and Nakdongbyeo. Twenty-one cultivars were susceptible cultivars such as Odaebyeo, Unkwangbyeo, Shinungbong1ho, Manabyeo, Hopyongbyeo, Borami, Damibyeo, Hwangchalbyeo, Sulgengbyeo, Nongrim6ho, Sasanishigi, Yunishigari, Chungmubyeo, Dongjin1ho, Huknambyeo, Guromy, Shanghehanghulna, Heukchalbyeo, Heukhwangbyeo, and Aranghwangchalbyeo.

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

Electrolytic Treatment of Ammonium Nitrogen and Nitrate Nitrogen by Bipolar Packed Bed Electrolytic Cell (충전복극전해조에 의한 암모니아성 및 질산성 질소의 전해처리)

  • Yun, Churl-Jong;Yu, Hyun-Chul;Kim, Jung-Sup;Lee, Bong-Seob;Kawk, Myoung-Hwa;Park, Seung-Cho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.686-689
    • /
    • 2005
  • This study was conducted to investigate the effect of ammonium and nitrate nitrogen removal to applied voltage, electrolytic time and activated carbon packing height. Batch bipolar packed bed electrolytic cell reactor was packed with $4{\times}8$ mesh granular activated carbon (GAC). Afterward electrolysis was performed in 20 V for 30 min. As a result, as the filling height adjusted to 80 mm high, the removal efficiency of ammonium nitrogen was 99.9%. and as the electrolytic time varied to 60 min, the removal efficiency of ammonium nitrogen was 97.6%. and in case of continuous electrolytic treatment of ammonium and nitrate nitrogen removal efficiency of total nitrogen was over 80% in bipolar packed bed electrolytic cell reactor for 72 hours as the packing height, sample concentration and input rate of sample adjusted to 280 mm, 30 mg/L, 6.7 mL/min, respectively.

An Experimental Study on the High Strength Lightweight Self-Compacting Concrete (고강도경량 자기충전콘크리트에 관한 실험적 연구)

  • Choi Yun-Wang;Kim Yong-Jic;Moon Han-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.923-930
    • /
    • 2005
  • This paper was to evaluate the high strength lightweight self-compacting concrete(HLSCC) manufactured by Nan-Su, which main factor, Packing Factor(PF) for mixing design, has been modified and improved. We have examined HLSCC performance at its fresh condition as well as its mechanical properties at the hardened condition. The evaluation of HLSCC fluidity has been conducted per the standard of second class rating of JSCE, by three categories of flowability(slump-flow), segregation resistance ability(time required to reach 500mm of slump-flow and time required to flow through V-funnel) and filling ability(U-box test) of fresh concrete. The compressive strength of HLSSC at 28 days has come out to more than 30MPa in all mixes. The relationship between the compressive strength-splitting tensile strength and compressive strength-modulus of elasticity of HLSSC were similar those of typical lightweight concrete. Compressive strength and dry density of HLSCC at 28 days from the multiple regression analysis resulted as $f_c=-0.16LC-0.008LS+50.05(R=0.83)\;and\;f_d=-3.598LC-2.244LS+2,310(R=0.99)$, respectively.

SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS (Ormocer 계열 수복재의 물성에 관한 연구)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.362-370
    • /
    • 2002
  • During the last two decades, many new filling materials and material groups have been developed. the number of available restoratives has increased dramatically, especially during the last 5 years. Ormocers are a new class of materials which are still under development with regard to dental applications. However, in the chemical literature these materials have been known for a long time and used for producing scratch resistant coatings on plastic spectacle lenses. It is a combination of inorganic and organic materials. 'Ormocer' is an abbreviation for 'Organically Modified Ceramics'. These compounds are also known in the literature as 'Ormosils' (organically modified silicates). Their chemistry is comparable to that of silicones and organic polymers. The purpose of this study was to determine of compressive strength and flexural strength of a ormocer (Admira) and to investigate the effects of water absorption in comparison with three composite resins(Z-100, Tetric Ceram, Surefil) and one compomer(Dyract AP). The following results were obtained ; 1. Admira had the lower compressive strength than Surefil, but no statistically difference with other materials at 1 day(p>0.05). 2. Admira had the lower flexural strength than all other materials at 1 day. From 2 days, Admits showed lower flexural strength than three composite resin(p<0.05). 3. There was not statistically significant difference of compressive and flexural strengths between hybrid composite resin group(Z-100, Tetric Ceram) and Packable resin group(Surefil) for experimental period(30 days)(p>0.05). 4. All five materials showed an increase in compressive and flexural strength till 2 days and showed a decrease from 7 days in water(p<0.05). 5. Each materials had the statistically similar behavior of compressive and flexural strengths over time(p>0.05).

  • PDF

Evaluation of Detection Ability of a Quantitative Light-Induced Fluorescence Digital Device for Initial Secondary Caries Lesion (Quantitative Light-Induced Fluorescence-Digital을 이용한 와동 내벽의 초기 이차우식병소 탐지 능력 평가)

  • Kim, Young Seok
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.116-122
    • /
    • 2017
  • The purpose of this study was to evaluate the detection ability of secondary caries using qunatitative light-induce fluorescence-digital (QLF-D) device. Twenty bovine teeth with cavity on surface were demineralized during 21 days for secondary caries lesion of cavity wall. After 21 days, cavity was filled using composite resin and cut the specimen in half with disc. Fluorescence loss of lesion on surface by time flow, cross sectional lesion, and lesion of filled or unfilled surface were analyzed using analysis software. ${\Delta}F$ (value of fluorescence loss) of the lesion on surface assessed by the QLF-D increased significantly over time up to 21 days. And ${\Delta}F$ value of lesion of filled surface is significantly lower than that of unfilled surface (p<0.001). ${\Delta}F$ of filled surface is 1.31 times of cross section lesion. The correlation of between ${\Delta}F$ of filled surface lesion and ${\Delta}F$ of cross section lesion was showed low agreement (0.026) and correlation of between ${\Delta}F$ of unfilled surface lesion and ${\Delta}F$ of cross section lesion was showed high agreement (0.613). In conclusion, secondary caries can be detected on surface using QLF-D. However, interference of fluorescence of filling material is the points to be especially considered for exact analysis of secondary caries lesion.

A Study on the Field Application of Epoxy Impregnation Method Using Elastic Storage Tube (탄성저장관을 활용한 에폭시 주입공법의 현장 적용성에 관한 연구)

  • Kim, Chun-Ho;Lee, Ho-Jin;Kim, Kyoung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.72-80
    • /
    • 2018
  • In this research, we tried to investigate the influence of concrete on cracks after applying to the actual construction site using the TPS construction method which can be easily charged by the mechanical injection method. To summarize the results, the following It is as follows. First, in the case of ultrasonic velocity, it can be seen that the ultrasonic wave passes rapidly at an average of about 36 mm / sec as compared with the syringe method when using the TPS method, and in the case of the injection depth, the syringe method In the case of TPS construction method, it showed an excellent tendency that 100% of the water retentive material was charged with all the formulations under a strong injection pressure. In the case of compressive strength, it was shown that the average was increased by 16.8% at the time of using the TPS construction method, and it was found to be structurally superior. Taken together, it is possible to confirm the behavior of the crack repairing agent by improving the quality by improving the strength and confirming the window installation by filling the injection material into the closed space at the crack site when using the TPS method compared with the syringe method. In addition, it is expected that construction time will be improved by shortening the construction period of about 5 days for the TPS construction method construction section 532 m, and usability will be expanded by the crack repair method of concrete structure.

Dental Hygienist's Harmful Factor Exposure and Recognition of Material Safety Data Sheets of Workplace Type (치과위생사의 근무기관 유형별 유해인자 노출과 물질안전보건자료 인식 연구)

  • Kim, Hae-Kyeong;Kim, Ji-Young;Oh, Na-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.540-549
    • /
    • 2018
  • This study was conducted on 238 dental hygienists working in Daegu and Gyeongbuk area. In order to understand the status of harmful transmission of dental materials by type of work, we compared the differences in exposure time and work environment characteristics of hospital types and investigated the difference in the degree of recognition of material safety data. The results of the study were as follows: In case of hospitals, the exposure time of dust generated from chemicals was the longest. Resin filling, contact with disinfectant. 37 workers (29.4%) and 14 workers (12.5%) answered that they perceive the question about whether they are aware of the material safety data sheet (MSDS) for dental materials. There were 18 hospital workers and 6 clinic workers who had experience reading MSDS before using dental materials. The respondents who answered that they provided the material safety data of the dental materials used had a 2.39 times MSDS in hospital workers. Therefore, by recognizing the health hazards of chemical substances in accordance with the characteristics of each type of hospital and continuing to conduct health and safety education, the work environment should be improved by establishing proper recognition of MSDS information. It suggests the necessity of a system that can strengthen the management of chemical information provision and guarantee the strategic approach and workers' right to know.

Characteristics of teeth referred to a dental university hospital for endodontic reason (근관치료적 이유로 치과대학병원으로 의뢰된 치아들의 특성)

  • Jeon, Su-Jin;Hwang, Soo-Jeong;Seo, Min-Seock
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.143-152
    • /
    • 2019
  • Purpose: The aim of this study is to investigate the characteristics of patients and teeth referred to a university dental hospital for endodontic problem. Materials and Methods: From January, 2017 to December, 2018, patients who were referred to a university dental hospital for endodontic problem were collected from clinical records. A total of 1171 patient records were analyzed. The status of the referred teeth was divided into three groups according to whether they were treated endodontically based on radiographs and clinical records at the time of referred visit. Results: 69.9% of the referred teeth were maxillary and mandibular first and second molars. The average time from referral to actual visit is 9.03 days and 65.6% of the case referred with referring letter. The most primary reasons of referral were persistent clinical symptom (pain, swelling, and sinus tract) (37.9%), diagnosis difficulty (16.7%), blockage of canal space (13.8%) and difficult tooth anatomy (11.4%). In the case of referral before endodontic treatment, the most primary reason of referral was failure to make a proper diagnosis. If the teeth were referred in the middle of endodontic treatment, the most primary reason of referral was persistent clinical symptom and blockage of canal space. In the case of referral after root canal filling, the most primary reason of referral was persistent clinical symptom. Conclusion: In the case of molars, the rate of persistent clinical symptom and blockage of canal space were the most primary reason of referral, and the rate of apical surgery and management of trauma was high in the case of anterior teeth.