The Construction Of Water Treatment Operation System Using Fieldbus (필드버스(Lonworks)를 이용한 수운영시스템 구축)

  • Park, J.S.;Kim, I.S.;Song, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2257-2259
    • /
    • 2004
  • Water Treatment Operation System is applied in most water treatment plants with DCS(Distributed Control System) or PLC(Programmable Logic Controller) system. But it has a lot of problems in viewpoint of cost and expansibilities. Therefore, we rose demand about a system that it was easier, convenient and a few costs. So, It was appeared at a Fieldbus as an alternative about this. It is used in ail industrial fields, but because of the economic reality that we can't removes the existing system, and cannot introduce new technology. Because it is actual to be hard to find an actual implementation reward and way of domestic fieldbus technology, we cannot be acknowledged with reliability in the industrial spot. Therefore, We is going to look into a fieldbus application reward in this paper. That is, We recognize structure and a kind of a fieldbus in a Chapter 2. And we is going to look into difference between a PLC method and fieldbus methods in a Chapter 3. Also, We are going to compare the system that used PLC with the system that used fieldbus (LonWorks). And the objects are JinAn and Wonju where a field bus was applied to.

  • PDF

Development of Mmotor Group Control System for Continuous Process Automation (연속공정 자동화를 위한 전동기 그룹제어시스템의 개발)

  • Cho, Y. J.;Oh, S. R.;Choy, I.;Ahn, H. S.;Kwon, S. H.;Lee, J. S.;Kim, K. B.;Lim, J. H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.218-224
    • /
    • 1990
  • A motor group control system is developed for continuous manufacturing processes such as rolling process or electrolytic tinning process. The control system consists of four subsystems ; Multi-Function Controller (MFC), Flexible Motor Drive (FMD), Bulky Input/Output (BIO), Graphic Console and Simulator (GCS). A graphic control language, called Function Block Language, is used to configure the control algorithms for each subsystem. All subsystem are linked together thru a field bus to communicate data with each other.

  • PDF

Performance Evaluation for Hydraulic Type Energy Regenerative System (유압식 에너지 회생시스템의 성능평가)

  • Jung, Dong-Soo;Kim, Hyong-Eui;Kang, E-Sok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.136-144
    • /
    • 2006
  • Vehicles usually have 3 types of speed pattern like acceleration, travel, and deceleration. It requires much driving energy from engine while accelerating, preserves much kinetic energy by inertia moment at travel speed, and releases the kinetic energy to the air while decelerating by the break system. If we accumulate the kinetic energy while decelerating and reuse the energy at the accelerating stage, then it can elevate the fuel efficiency, reduce the emission and improve the motive power. This paper proposes a hydraulic type energy regenerative system which converts the kinetic energy into hydraulic energy at the stage of deceleration and reuses it at the starting and accelerating stage of vehicles. The test equipment which has the field condition of city bus was prepared to evaluate the performance for energy regeneration. The test results show that both energy regeneration efficiency and fuel efficiency are improved significantly and the emission is reduced notably.

Development of Dynamic ID Allocation Algorithm for Real-time Quality-of-Service of Controller Area Network (Controller Area Network 의 실시간 서비스 품질 향상을 위한 동적 ID 할당 알고리즘 개발)

  • Lee, Suk;Ha, Kyoung-Nam;Lee, Kyung-Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.40-46
    • /
    • 2009
  • Recently CAN (Controller Area Network) is widely used as an in-vehicle networking protocol for intelligent vehicle. The identifier field (ID) of CAN is used not only to differentiate the messages but also to give different priorities to access the bus. This paper presents a dynamic 10 allocation algorithm in order to enhance the real-time quality-of-service (QoS) performance. When the network traffic is increased, this algorithm can allocate a network resource to lower priority message without degradation of the real-time QoS performance of higher priority message. In order to demonstrate the algorithm's feasibility, message transmission delays have been measured with and without the algorithm on an experimental network test bed.

A force-Guided Control with Adaptive Accommodation Bor Complex Assembly

  • Sungchul Kang;Kim, Munsang;Lee, Chong W.;Lee, Kyo-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.14-19
    • /
    • 1998
  • In this paper, a target approachable force-guided control with adaptive accommodation for the complex assembly is presented. The complex assembly (CA) is defined as a task which deals with complex shaped parts including concavity or whose environment is so complex that unexpected contacts occur frequently during insertion. CA tasks are encountered frequently in the field of the manufacturing automation and various robot applications. To make CA successful, both the bounded wrench condition and the target approachability condition should be satisfied simultaneously during insertion. By applying the convex optimization technique, an optimum target approaching twist can be determined at each instantaneous contact state as a global minimum solution. Incorporated with an admissible perturbation method, a new CA algorithm using only the sensed resultant wrench and the target twist is developed without motion planning nor contact analysis which requires the geometry of the part and the environment. Finally, a VME-bus based real-time control system is built to experiment various CA task. T-insertion task as a planar CA and double-peg assembly task as a spacial assembly were successfully executed by implementing the new force-guided control with adaptive accommodation.

  • PDF

Source Localization in the Anechoic Basin at KRISO/KORDI by Using MUSIC Algorithm (무향수조 내에서 MUSIC 알고리듬을 이용한 음원의 위치 추적)

  • Kim, Sea-Moon;Choi, Young-Cheol;Lee, Chong-Moo;Park, Jong-Won;Lim, Yong-Kon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.68-72
    • /
    • 2002
  • Localization with array sensors has been applied for not only military but also non-military purposes. The identification of submarines and fish finding are those examples. Nowadays the demand for noise identification is increasing to characterize noise sources and improve acoustic performance of underwater acoustic equipment. For that reason KRISO/KORDI recently constructed an anechoic basin which bus reflection only at the free surface. This paper suggests a noise identification methods using MUSIC algorithm in such an acoustic field. For comparison phase delay sum and minimum valiance methods are also described. At first basic principles are described. A several numerical simulations are also performed. The results say that reflection effect many cause a new non-real source although good estimation is obtained under no reflection conditions.

  • PDF

The Design and Implementation of a Mobile-agent System for SoftPLC (SoftPLC를 위한 모바일 에이전트 시스템의 설계 및 구현)

  • Bae, Hae-Gwang;Choi, Young-Hyun;Min, Gi-Sung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.31-34
    • /
    • 2006
  • 최근의 PLC는 Ethernet 통신, Field Bus등 새로운 통신규약에 호환성을 갖고 있으며 점점 빠른 연산 속도의 초소형 PLC로 발전해 나가고 있고 공장 자동화와 FMS(Flexible Manufacturing System)에 따른 PLC의 요구는 과거 중규모 이상의 릴레이 제어반 대체 효과에서 현재 고기능화, 고속화의 추세로 소규모 정작 기계에서 대규모 시스템 설비에 이르기까지 적용되고 있다. 그러나 현재 사용되고 있는 PLC는 각 제조사마다 하드웨어형식은 유사하지만 소프트웨어형식인 제어 명령어들이 다르기 때문에 각각의 PLC마다 호환이 되지 않는다는 문제점을 가지고 있어 이 제어 명령어들의 호환성을 위한 솔루션이 필요하다. 이를 해결하기 위하여 본 논문은 IEC1131-3의 표준 언어를 중심으로 제어할 수 있는 Mo-aPLC라는 모바일 에이전트 기반의 softPLC시스템을 제안하였다. 이 시스템은 모바일 에이전트들이 지적 대리인으로서 IEC1131-3의 표준 언어를 제어시스템 제작자에게 활용되어 질 수 있는 코드인 IL언어로 변환하고 이를 랭귀지 프로그래머가 활용할 수 있는 코드인 표준 C코드로 변환하는 것이다. 이 시스템으로 인해 제어시스템 제작자와 랭귀지 프로그래머들이 활용할 수 있는 코드들이 생성되는 것과 표준 C코드로 변환함으로서 논리적인 디버깅(dubugging)이 용이하다는 것을 알 수 있었다.

  • PDF

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

Application Technology and Development of CAN Fieldbus Modules for Building Automation and Control System (빌딩자동제어시스템용 CAN 필드버스 모듈개발 및 적용기술에 관한 연구)

  • Hong, Won-Pyo;Seo, Young-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.121-127
    • /
    • 2004
  • The controller area network(CAN) was originally developed to support cheap and rather simple automative applications, However, because of the its performance and low cost, it is also being considered in automated manufacturing and process control environments to interconnect intelligent devices, such as modem sensors and actuators. This paper presents a new application technology of the developed CAN control modules for the automated doors in building automation system Key pad and RF methods are used to open and close the automated door by the slave CAN module with CAN Protocol. BAS application technology of CAN field bus modules is also presented firstly in our nation.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.