• 제목/요약/키워드: Field-bus

검색결과 210건 처리시간 0.023초

Bi계 고온 초전도 선재 부스바에서의 자기 자장 해석 (Analysis of Self Magnetic Field Effects in a Bi-2223 Stacked Superconducting Bus Bar)

  • 강형구;나완수;주진호;유재무;오상수;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.302-304
    • /
    • 1998
  • Self magnetic field in a Bus bar usually degrades the critical current in it. Actually the total critical current of a Bus bar is not the same as the sum of total critical current of each stacked HTS tape. This is due to the self field effects in a bus bar. To reduce the degradations of critical current in a bus bar, we need to analyze the self field distributions in a bus bar. Conceptually, by rearranging the each stacked tapes, the self field effects can be minimized. In this paper, we calculate the self magnetic field distributions across a bus bar analytically, with the variations of the relative angle of the two conductors in a go-and-return pair. As a result, we suggest that the optimum relative angle exist which minimize the self field effect in a bus bar.

  • PDF

CICC 형태의 초전도 버스 선에서 냉각 및 자기장에 의한 응력 해석 (Analysis of the stresses induced by magnetic field and cooling in the CICC type superconducting bus-line)

  • 이호진;남현일;김기백;홍계원
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.20-25
    • /
    • 2000
  • A CICC type superconducting bus-line electrically connecting a superconducting magnet to a power supply is cooled down to low temperature under the external magnetic field during operation. The thermal contraction during the cooling may be constrained by the supports which are installed to protect the bus-line from Lorenz magnetic forces. This constrained contraction causes thermal stresses in the bus-line to release thermal contraction. The minimum stress conditions in the bus-line may be optimized by controlling the supporting arrangement considering the thermal contraction and the external field. The analytical method to find optimal supports arrangement was suggested by using the beam theory, and numerical calculation using commercial code was performed to verify the suggested analytical optimization method.

  • PDF

상분리 모선의 자계 및 와전류 특성 해석 (Analysis of the Magnetic Field and Eddy Current Characteristics in Isolated Phase Bus System)

  • 김진수;하덕용;최승길;강형부
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권10호
    • /
    • pp.509-516
    • /
    • 2001
  • Isolated phase bus(IPS) has a special structure for carrying large current generated by a generator to a main transformer. In the analysis of IPB, the understanding of the magnetic field distribution generated by large current is important. Especially, while the bus conductor current is flowing, almost same amount of current as bus conductor current is induced in the enclosures under the influence of time varying magnetic field, and therefore the large electric loss and the deterioration of insulating capability might occur due to Joule heating effect. Hence for the optimal design of IPB satisfying the condition to minimize the loss, the accurate analysis of magnetic field distribution and the eddy current characteristics of three phase isolated phase bus have been investigated. In the analysis of time varying magnetic field, instead of finite difference method(FDM) which is generally used, finite element method with phasor concept is investigated under the assumption that the bus current is purely sinusoidal. The characteristics is studied along the phase angle by comparing the effect of eddy current on the magnetic field distribution with the case that eddy current is not considered, and also the effect of material, thickness and radius of enclosure on the eddy current distribution is discussed.

  • PDF

Configuration of Actuator and Sensor Interface Bus Network using PLC

  • Luu, Hoang-Minh;Park, Young-San
    • 해양환경안전학회지
    • /
    • 제20권3호
    • /
    • pp.318-322
    • /
    • 2014
  • A kind of field bus called Actuator and Sensor interface bus(AS-i) was designed in this paper. The configuration of AS-i network system used Application Specific Integrated Circuit(ASIC) SAP5S chip and PLC S7-200 station, which included CPU 224 and AS-i master module CP 243-2. We also created an example program for PLC S7-200 to control AS-i network. The fire and smoke detection system was made with AS-i network system that was designed. This system had got more advantages than other system such as number of stations, easy installation, wide working area, etc. And designed system can be used as a partner network for higher level field bus networks.

비용 효율이 높은 24kV급 고압배전반 개발을 위한 Bus Bar 사이즈에 따른 전·자기 손실 특성 분석 (A Study on the Characteristics of the Electric Field and Electromagnetic Loss according to Bus Bar Size for a cost-effective 24kV High Voltage Switchgear)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.220-224
    • /
    • 2012
  • The analysis on the bus bar effect is conducted to develop a cost effective 24kV/2,000A switchgear. The temperature enclosures and bus bars could rise due to several heat sources such as eddy current losses and copper losses. Therefore, a study on the characteristics of the electric field intensity and electromagnetic loss according to the bus bar size in a bus bar compartment is essential to design a electrically reliable high voltage switchgear. It is investigated that the electromagnetic influence to the temperature rising and the dielectric stability according to various bus bar sizes by using finite element method(FEM). The electric field intensity and electromagnetic loss according to various bus bar sizes are calculated to design a reliable and a high voltage switchgear. As results, it is found that the electromagnetic loss and the dielectric stability of bus bar could be determined by a bus bar size. It means that a cost effective 24kV/2,000A high voltage switchgear could be developed by selecting the proper size of a bus bar. Also, it is recognized that the electromagnetic characteristics according to various bus bar sizes in order to design an electrically stable high voltage switchgear when the enclosure size is determined as a fixed value. Futhermore, studies on the various nominal voltage class and bus bar sizes will be conducted to develop a cost effective high voltage switchgear.

필드버스를 이용한 전동차 차량간 통신 시스템 연구 (A Study on Train Communication Network for EMU using FieldBus)

  • 이수길;한성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1266-1268
    • /
    • 2001
  • ProfiBus provides real-time data communication among field devices in the EMU (Electrical Multiple Unit) and TCMS (Train Control Monitoring System). This paper presents an adapt to Train Communication Network for EMU using ProfiBus DP(Decentralized Periphery) mathod, which is the layer 2 DDLM(Direct Data Link Mapper) protocol of ProfiBus.

  • PDF

22.9[kV] 모선의 계절별 부하특성에 관한 연구 (A Study on the Seasonal Load Characteristics in 22.9[kV] Bus)

  • 이종필;임재윤;지평식;김기동;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.279-286
    • /
    • 2001
  • A load modeling, micro method, is performed by component load modeling, load composition rate estimation and aggregation of component load model, etc. The load model obtained from this process must be applied to actual load bus to verify it and to get reliable load model. But it is difficult to apply every load bus due to al lot of load buses and complex experiment. This paper proposed the field test method in load bus to verify the load modeling. For appropriate field test, representative load buses are selected by the proposed algorithm considering the composition rate of user category in all load buses. The field tests were performed at selected load buses to obtain load characteristics of bus by time and seasonal without blackout. The results of measurement and analysis are presented in detail.

  • PDF

연성해석을 이용한 초고압 모선부 온도 상승 예측 기술 (An Estimation Technology of Temperature Rise in GIS Bus Bar using Three-Dimensional Coupled-Field Multiphysics)

  • 윤정훈;안희섭;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.675-676
    • /
    • 2006
  • This paper shows the temperature rise of the high voltage GIS bus bar. The temperature rise in GIS bus bar is due to Joule's losses in the conductor and the induced eddy current in the tank. The power losses of a bus bar calculated from the magnetic field analysis are used as the input data for the thermal analysis to predict the temperature. The required analysis is a couple-field Multiphysics that accounts for the interactions between three-dimensional AC harmonic magnetic and fluid fields. The heat transfer calculation using the fluid analysis is done by considering the natural convection and the radiation from the tank to the atmosphere. Consequently, because temperature distributions by couple-field Multiphysics (coupled magnetic-fluid) have good agreement with results of temperature rise test, the proposed couple-field Multiphysics technique is likely to be used in a conduction design of the single-pole and three pole-encapsulated bus bar in CIS..

  • PDF

전력계통 안정도 정밀해석을 위한 적정 부하모델 개발 (Development of Accurate Load Model for Detailed Power System Stability Analysis)

  • 박시우;김기동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.201-205
    • /
    • 2001
  • This paper presents the load modeling process and bus load models for KEPCO power system. At first, load devices commonly used in KEPCO power systems were selected, and tested for measuring the voltage and frequency sensitivity of active and reactive power. From this test, about 40 voltage and frequency dependent load models have been obtained. The bus load composition rate for KEPCO power system has been determined using the various recent surveys and papers in order to develop the load model for a power system bus. To verify the accuracy of developed bus load models, the field test for measuring active and reactive power according to artificial variation of the bus voltage was performed at 8 substations for spring summer, autumn, winter cases. With data of this seasonal field test, more reliable bus load models for KEPCO power systems were developed.

  • PDF

칩 테스트를 위한 UART-to-APB 인터페이스 회로의 설계 (UART-to-APB Interface Circuit Design for Testing a Chip)

  • 서영호;김동욱
    • 한국항행학회논문지
    • /
    • 제21권4호
    • /
    • pp.386-393
    • /
    • 2017
  • 칩을 개발하는 과정에서 설계된 칩의 검증을 위해 FPGA (field programmable gate array)를 많이 이용한다. FPGA에 다운로드 된 회로를 검증하기 위해서는 FPGA로 데이터를 입력해야 한다. PC와 외부 보드를 통한 칩과의 통신을 위한 많은 방식이 있지만 가장 간단하고 쉬운 방법은 범용 비동기화 송수신기 (UART; universal asynchronous receiver/transmitter)를 이용한 방식이다. 최근 대부분의 회로는 AMBA (advanced microcontroller bus architecture) 버스에 연결되도록 설계되어 있다. 즉, 설계된 회로를 검증하기 위해서는 UART를 거친 후에 AMBA 버스를 통해 데이터를 전달해야 한다. AMBA 버스도 최근에 버전 4.0까지 거치면서 다양한 버전이 존재하는데 간단히 테스트를 하기 위한 용도로는 APB (advanced peripheral bus)가 적합하다. 본 논문에서는 UART-to-APB 인터페이스를 위한 회로를 설계하였다. Verilog HDL을 이용하여 설계된 회로는 Altera Cyclone FPGA에서 구현되었고, 최대 380 MHz의 속도에서 동작이 가능하였다.