• Title/Summary/Keyword: Field strength

Search Result 3,465, Processing Time 0.045 seconds

Developments of Low Frequency Electric Field Sensor using $Ti:LiMbO_3$ Optical Modulator ($Ti:LiMbO_3$ 광변조기를 이용한 저주파 전계센서의 개발)

  • Choi, Young-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.214-221
    • /
    • 2001
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a $Ti:LiMbO_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1 V/cm to 60 V/cm at 60Hz through 100 kHz. Using a probe antenna of $10\;mm{\times}10\;mm$, the output voltage of $10^{-2}\;mV$ was measured with respect to the electric field strength of 0.1 V/cm at 60 Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.

  • PDF

Developments of Extremely Low Frequency Electric Field Sensor using Guided-wave Optical Modulator (광도파로형 초저주파(ELF) 전계계측 센서의 개발)

  • Choe, Yeong-Gyu;Kim, Mun-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.6
    • /
    • pp.1-7
    • /
    • 2002
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a Ti:LiNbO$_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1V/cm to 60V/cm at 60Hz through 100KHz. Using a probe antenna of 10mm$\times$10mm, the output voltage of 10㎷ was measured with respect to the electric field strength of 0.1V/cm at 60Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.

Characteristics of Undrained Shear Strength of Yangsan Clay (양산지역 점토의 비배수 전단강도 특성)

  • 김길수;임형덕;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.71-78
    • /
    • 2000
  • SHANSEP method involves the consolidation to stresses in excess of the preconsolidation pressure in order to overcome sample disturbance effect. The concept of SHANSEP is based on an approach to laboratory test which attempts to reproduce the in-situ conditions more closely than is possible in routine tests and evaluates normalized strength parameters for the soil as a function of OCR. But SHANSEP method can be applied only to fairly uniform clay deposits, and is unsuitable for a random deposit. In this study, CK/sub o/U triaxial compression test and incremental loading consolidation test were performed for the application of SHANSEP method on Yangsan clay. During the K/sub o/-consolidation, triaxial specimens were consolidated to stress equal to two times the in-situ vertical effective stress. And for overconsolidated condition, the specimens were swelled to a known vertical effective stress in order to have the desired OCR. With the results of CK/sub o/U triaxial compression test using the block samples, the relationship between c/sub u//σ/sub vc/' and OCR on Yangsan clay was established. For evaluating the undrained shear strength of Yangsan clay with depth, CK/sub o/U triaxial compression test was performed using the piston samples taken from Yangsan site. And also undrained shear strength was analyzed from the in-situ test such as Cone Penetration Test(CPT), Dilatometer Test(DMT), and Field Vane Test(FVT) and was compared with that of CK/sub o/U triaxial compression test.

  • PDF

Field Case Study of Mechanized Form Roads Pavement Construction using Cellulose Fiber Reinforced Concrete (셀룰로오스 섬유보강 콘크리트를 사용한 기계화경작로 확·포장공사의 현장사례 연구)

  • Park, Jong Gun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.2
    • /
    • pp.47-56
    • /
    • 2015
  • At the present, the mechanized form roads pavement was constructed with plain concrete. Mostly, it was used by welded wire mesh for preventing crack. Cellulose fibers for the reinforcement of concrete offer relatively high levels of elastic modulus, fiber count (per unit weight), specific surface, and bond strength to cement-based materials. The construction of concrete pavement confirmed that cellulose fiber reinforced concrete was applicable to mechanized form roads pavement. In the study, cellulose fibers were used here at 0.08 % volume fraction, which is equivalent to a fiber content of $1.2kg/m^3$. Cellulose fiber reinforced concrete were compared with plain concrete. Field test results indicated that cellulose fiber reinforced concrete showed slightly to increase of 28 days compressive strength and improved the initial strength. it tended to increase of splitting tensile strength. Test results showed that the slump and air content tend to decreased. but, the variation of air contends is very little. Also, construction cost of cellulose fiber reinforced concrete is less than about 25.7 % the case of welded wire mesh previously used. Therefore, The cost reduction is expected to be possible in construction site by mechanized form roads pavement.

Spectral Analysis of On-the-go Soil Strength Sensor Data (이동식 토양 강도 센서 데이터 주파수 분석)

  • Chung, Sun-Ok;Suduth, Kenneth A.;Tan, Jinglu
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.355-361
    • /
    • 2008
  • As agricultural machinery has become larger and tillage practices have changed in recent decades, compaction as a result of wheel traffic and tillage has caused increasing concern. If strategies to manage compaction, such as deep tillage, could be applied only where needed, economic and environmental benefits would result. For such site-specific compaction management to occur, compacted areas within fields must be efficiently sensed and mapped. We previously developed an on-the-go soil strength profile sensor (SSPS) for this purpose. The SSPS measures within-field variability in soil strength at five soil depths up to 50 cm. Determining the variability structure of SSPS data is needed for site-specific field management since the variability structure determines the required intensity of data collection and is related to the delineation of compaction management zones. In this paper, soil bin data were analyzed by a spectral analysis technique to determine the variability structure of the SSPS data, and to investigate causes and implications of this variability. In the soil bin, we observed a repeating pattern due to soil fracture with an approximate 12- to 19-cm period, especially at the 10-cm depth, possibly due to cyclic development of soil fracture on this interval. These findings will facilitate interpretation of soil strength data and enhance application of the SSPS.

A Study on Variation of Rock Strength due to Weathering and It도s Estimation (암석의 풍화에 따른 강도변화 특성 및 강도추정에 관한 연구)

  • 정형식;유병욱
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.71-94
    • /
    • 1997
  • It is important to evaluate rock strength in order to check stability of a rock slope or to design a structure built on rock. However, test methods used for the evaluation have some difficulties since rock samples provide various deviation of strength due to micro cracks in the samples and teat errors, Also, reliable data have not been accumulated for the rock strength in Korea. Therefore, simple teat methods that can be used easily for investication of rock strength in field or in laboratory are not provided sufficiently yet. This study is to investigate variation of the rock strength due to the degree of weathering and to evaluate the degree of weathering by types of rocks, by using data that have been obtained for several years. Therefore, it is possible to provide a relationship between several rock strength values by performing tests such as uniaxial compression teat, point load test, schmidt hammer teat, absorption ratio best and slaking durability tests. The equations of relationships that can be used to estimate rock strength by using simple test methods in field and in laboratory are proposed.

  • PDF

An Investigation on the Quality of High-Strength Shotcrete and the Long Term Durability using Combined Deterioration Test (고강도 숏크리트의 품질평가와 복합열화시험을 통한 장기내구성 검토)

  • Ma, Sang-Joon;Kim, Dong-Min;Choi, Jae-Seok;Ahn, Kyung-Chul;Kim, Sun-Myung;Ko, Jin-Kon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.906-915
    • /
    • 2006
  • In this study, Field test was performed using high-quality additions and accelerators to obtain the improvement of the strength on domestic shotcrete and quality test based on EFNARC was performed. In addition, Deterioration test that combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of field test, a promotion ratio of early strength is $90\sim97%$ in case of using alkali-free accelerators. And a compressive strength of shotcrete using Micro-silica fume was $45.2\sim55.8MPa$ and the flexible strength was $5.01\sim6.66MPa$, so a promotion ratio of strength was $37\sim79%$, $17\sim61%$ respectively. It was showed that increment effect of strength by the Micro-silica fume replacement of $7.5\sim10%$ for cement mass was remarkable. It was also realized that application of Micro-silica fume to shotcrete reduced deterioration and improved a long-term durability of shotcrete.

  • PDF

Torsional Resistance of RC Beams Considering Tension Stiffening of Concrete (콘크리트의 인장강성을 고려한 RC보의 공칭비틀림강도)

  • 박창규
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.24-32
    • /
    • 2002
  • The modified compression field theory is already applied in shear problem at some code(AASHTO-1998) partly. Nominal shear strength of concrete beam is sum of the concrete shcar strength and the steel shear strength in the current design code. But Torsional moment strength of concrete is neglected in the calculation of the nominal torsional moment strength of concrete beam In the current revised code. Tensile stress of concrete strut between cracks is still in effect due to tension stiffening effect. But The tensile stresses of concrete after cracking are neglected in bending and torsion In design. The torsional behavior is similar to the shear behavior in mechanics. Therefore the torsional moment strength of concrete should be concluded in the nominal torsional moment strength of reinforced concrete beam. This paper shows that the torsional moment strength of concrete is caused by the average principal tensile stress of concrete. To verify the validity of the proposed model, the nominal torsional moment strengths according to two ACI codes (89, 99) and proposed model are compared to experimental torsional moment strengths of 55 test specimens found in literature. The nominal torsional moment strengths by the proposed model show the best results.

An Experimental Study on Early Strength Development of High-Strength Concrete to Apply Slip-Form (슬립폼 적용을 위한 고강도콘크리트의 조기강도 발현성상에 관한 실험적 연구)

  • 주지현;여동구;강석표;길배수;남재현;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.355-358
    • /
    • 2000
  • Nowadays, with high-storied and large-sized of structures, high-strength concrete is applied to the various kinds of concrete structure. Among of them, for reduction of completion time, high-strength concrete is applied to the high-storied tower, building which is constructed continuously by the slip-form method and it is expected to be on the increase. In this case, it is very important to grasp development of early-strength to apply the slip-form method. But the strength data prior 1 day is rare. Therefore, to apply slip-form method in field, this study aim is to present basic data for development of early-strength of high-strength concrete, through examining development of strength by different curing temperature, replacement of fly-ash.

  • PDF

An Experimental Study in Strength Control by Prediction Strength of Concrete using Equivalent Age in Construction Field (등가재령을 이용한 콘크리트의 강도 예측에 의한 건설생산현장에서의 강도관리에 관한 실험저 연구)

  • 주지현;최성우;박선규;김배수;남재현;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.287-290
    • /
    • 2000
  • Nowadays, strength control is performed by test of compressive strength of concrete which is taken in construction filed. But because it is possible to confirm only compressive strength of concrete by that way, it is difficult to performing strength control pr process plan, So, if we can predict compressive strength of concrete, we can decide when shores and forms can be removed safety, plan process efficiently. This study intends to propose basic data for strength control as determination the time of forwoak removal through investigating propriety of strength prediction using Freiesleben function.

  • PDF