• Title/Summary/Keyword: Field measuring

Search Result 2,063, Processing Time 0.054 seconds

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • v.15 no.1
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

The Accuracy Analysis of RTK-GPS by Field Calibration in Plane Surveying (국지측량에서의 현장 Calibration에 의한 RTK-GPS 정확도 분석)

  • Park, Woon-Yong;Shin, Dong-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.2 s.20
    • /
    • pp.87-95
    • /
    • 2002
  • Real-time Kinematic GPS enables high accuracy Positioning by real time. If ambiguity use an integer solution, can obtain accuracy of several 'mm', and can obtain accuracy of tens 'em' if use real solution. In this study, We accomplish surveying by existent traditional surveying techniques (Total Station), Static GPS techniques and RTK-GPS techniques by Field Calibration about uniformity measuring point and then compared and ana1yzed each techniques positioning accuracy etc.. Result that achieve by Static-GPS in Plane area, about all measuring points, expressed error fewer than 3cm. Result that achieve RTK-GPS Surveying by Field Calibration in Plane area, could know that RTK-GPS techniques by Field Calibration is available in Plane area because expressing errors fewer than all 6cm, except case that do not get fixed solution of ambiguity Field Calibration RTK-GPS could know economically than existent conventional type measurement and existent GPS's measurement techniques that efficiency is very high.

  • PDF

Pre-processing of load data of agricultural tractors during major field operations

  • Ryu, Myong-Jin;Kabir, Md. Shaha Nur;Choo, Youn-Kug;Chung, Sun-Ok;Kim, Yong-Joo;Ha, Jong-Kyou;Lee, Kyeong-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • Development of highly efficient and energy-saving tractors has been one of the issues in agricultural machinery. For design of such tractors, measurement and analysis of load on major power transmission parts of the tractors are the most important pre-requisite tasks. Objective of this study was to perform pre-processing procedures before effective analysis of load data of agricultural tractors (30, 75, and 82 kW) during major field operations such as plow tillage, rotary tillage, baling, bale wrapping, and to select the suitable pre-processing method for the analysis. A load measurement systems, equipped in the tractors, were consisted of strain-gauge, encoder, hydraulic pressure, and radar speed sensors to measure torque and rotational speed levels of transmission input shaft, PTO shaft, and driving axle shafts, pressure of the hydraulic inlet line, and travel speed, respectively. The entire sensor data were collected at a 200-Hz rate. Plow tillage, rotary tillage, baling, wrapping, and loader operations were selected as major field operations of agricultural tractors. Same or different farm works and driving levels were set differently for each of the load measuring experiment. Before load data analysis, pre-processing procedures such as outlier removal, low-pass filtering, and data division were performed. Data beyond the scope of the measuring range of the sensors and the operating range of the power transmission parts were removed. Considering engine and PTO rotational speeds, frequency components greater than 90, 60, and 60 Hz cut off frequencies were low-pass filtered for plow tillage, rotary tillage, and baler operations, respectively. Measured load data were divided into five parts: driving, working, implement up, implement down, and turning. Results of the study would provide useful information for load characteristics of tractors on major field operations.

Estimating the Soil Volume Conversion Factor of Weathered Ground with Consideration of Field Situations

  • Jin, Kyu-Nam;Cho, Gye-Chun;Lee, Jung-Min;Ryu, Hee-Hwan;Park, Sung-Wook
    • Land and Housing Review
    • /
    • v.2 no.2
    • /
    • pp.145-155
    • /
    • 2011
  • It is very important for successful construction to estimate the soil volume conversion factor of domestic weathered ground accurately and reasonably. However, it is very difficult to quantify the weathering degree of weathered ground at the field, so that the soil volume conversion factor used in Korea is often dependent upon the standard of foreign countries. Besides, the soil volume conversion factor of domestic weathered ground has been rarely studied and the use and accuracy of the soil volume conversion factor have been questioned persistingly. This study suggests a simple but robust method for estimating the soil volume conversion factor and measuring the weathering degree reasonably, and attempts to establish the utilization of a soil volume conversion factor measurement system based on experimental and analytical results. We made relationship between electrical resistivity and weathering degree presented from weathering index obtained through laboratory tests using field samples, and an estimation method of in-situ weathering degree for granites and a calculation method of soil volume conversion factor using electrical resistivity. And also, we suggested the photogrametry measurement-equipment system for measuring the volume of cargo box and the application plan of stand equipment and RFID for calculating the earth volume and distinguishing buggies in order to design the measurement system for soil volume conversion factor applicable to the field. Ultimately, the Weathered Earth-work Management Program (WEMP) was developed, so field managers may easily obtain the information about earth volume and soil volume conversion factor at the weathered ground.

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

Full-field Distortion Measurement of Virtual-reality Devices Using Camera Calibration and Probe Rotation (카메라 교정 및 측정부 회전을 이용한 가상현실 기기의 전역 왜곡 측정법)

  • Yang, Dong-Geun;Kang, Pilseong;Ghim, Young-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.237-242
    • /
    • 2019
  • A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.1
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

A Study on the Ultrasonic Effect for Turbulence Enhancement in the Flow Field of a Coaxial Circular Pipe (동심원관 유동장에서 난류증진을 위한 초음파 영향에 관한 연구)

  • Song, Min-Geun;Koo, Ja-Hoon;Lee, Sang-Bum;Son, Seung-Woo;Ju, Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.742-747
    • /
    • 2001
  • A study on the ultrasonic effect for turbulence enhancement is carried out in the horizontal flow field of a coaxial circular pipe. A large transparent acryl tank is made to perform several experiments for the above research. The front flow field from jet exit is divided as 4 measuring regions to observe characteristics of the above flow field according to those with and without ultrasonic. An ultrasonic transducer with 2MHz high frequency is used to give them the ultrasonic forcing. Characteristics such as the velocity distribution, the kinetic energy and the turbulence intensity are visualized, observed, examined and considered at Re No. 2000. In results, it is clarified that the ultrasonic increases the turbulence enhancement. And the optimum and harmonious intensity suited to the power of flow is needed to maximize the turbulence enhancement.

  • PDF

Study on the Poling Conditions of PZT Ceramics with $MnO_2$ additive (압전 세라믹 PZT에 첨가된 $MnO_2$가 분극조건에 미치는 영향)

  • Choi, H.I.;Lee, J.H.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.247-250
    • /
    • 1991
  • In this paper, we have investigated the poling conditons depending upon the electric field and temperature for PZT ceramics with various stoichiometry prepared by wet direct method, and $MnO_2$ dopant. The electric field required for saturation polarization was plotted against temperature $(1,000/T^{\circ}K)$ so that the required field could be estimated at any given temperature by measuring the charge displaced during poling. From this curve it should be possible to predict the field required to produce maximum domain switching at temperature below the Curie temperature, when $MnO_2$ dopant was added to the PZT ceramics, the electric field required for saturation polarization was lowered than that of undoped PZT samples.

  • PDF