• 제목/요약/키워드: Field load tests

검색결과 472건 처리시간 0.032초

복합소재 교량 바닥판 '델타데크'의 구조적 특성과 현장적용 (Structural Characteristics and Field Application of 'Delta Deck' Composite Bridge)

  • 이성우;박신전;김병석;정규상
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.201-208
    • /
    • 2004
  • To substitute conventional reinforced-concrete bridge deck, glass composite precast bridge deck - Delta Deck/sup TM/, which possesses advantages of light weight, high strength, corrosion resistance and durability, is developed for the DB24 truck load. Pultruded composite bridge deck is designed and fabricated. To verify serviceability and structural safety, finite element analysis, structural testing such as flexural test, local fatigue test, flexural fatigue test and field tests are conducted. In this paper structural characteristics of developed deck and its field application in Korea is presented.

  • PDF

현장시험을 통한 인발하중이 지배적인 원형기초의 거동 특성 연구 (A Study on the Behavioral Characteristics of a Circular Foundation Dominated by Pull-Out Load through Field Test)

  • 신경하;이승호;이동혁;박두희
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.53-62
    • /
    • 2021
  • 최근 국내에서 활발히 적용되고 있는 LRFD 설계법의 합리적인 적용을 위하여 상대적으로 사례가 부족한 인발하중 및 수평하중의 연구를 위하여 사회적으로 중요한 구조물인 송전철탑의 기초 형태를 바탕으로 한 원형기초를 풍화토 단일지층과 풍화토, 풍화암, 연암으로 구성된 혼합지층에서의 현장실증시험을 수행하여 인발하중 및 수평하중에 대한 각 지층의 저항성 분석을 통해 설계에 영향을 미칠 수 있는 인자에 대하여 연구하였다.

가속수명시험을 위한 KTX 구조물의 S-N 선도 추정 (S-N Curve Estimation of a KTX Structure for an Accelerated Life Testing)

  • 정달우;최낙삼;박수한
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.384-389
    • /
    • 2008
  • An accelerated fatigue test is essentially required to maintain the reliability of the actual structure of KTX under operation conditions. However, actual fatigue life cannot be obtained if specimens are not adequate to the conventional fatigue test. Moreover component maker did not provide data of loading stress (S) - cycles at the failure (N). In this study, we suggest a prediction method of the S-N curve for establishing an accelerating test under various load levels. Load history was acquired from the field tests. A Rainflow method was used on the cycle counting of the field load data, and then, an S-N curve was obtained through the iteration process under the condition that the damage index satisfies to 1 in the Miner's rule.

  • PDF

Performance analysis of a 746 W HTS generator equipped with 70 A class contactless superconducting field exciter

  • Chae, Yoon Seok;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.1-6
    • /
    • 2020
  • This paper presents the analysis results on the electrical output performance characteristics of a 746 W high temperature superconducting generator (HTSG). The HTS field winding is charged by non-contact excitation method, i.e., contactless superconducting field exciter (CSFE) which is originated by rotary flux pump based on permanent magnet. In this paper, the preliminary current charging test was carried out using a 70 A CSFE to evaluate the performance of field exciter and analyze its non-contact excitation characteristics for the full-scale HTS field winding of the 746 W HTSG. First, the various contactless current-charging tests were conducted using assembly with HTS field winding and CSFE. Then, in order to estimate the output power performance characteristics of the 746 W HTSG, finite element analysis was conducted based on field excitation information which is experimentally measured under various operating conditions. Finally, the electrical output characteristics in no-load and load models were simulated by two-dimensional transient solver in ANSYS electromagnetics 19.0 release.

30kVA 초전도 전동기의 기기상수 (Machine Constants of 30 kVA Superconducting Synchronous Motor)

  • 최경달;한송엽;츠키지히로시;호시노토모노리;무타이쯔야
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1996
  • For the test of the operating characteristics as a moor, a 20 kVA super conducting synchronous machine with rotating field windings has been made in Saga university, Japan from 1991. Before the load tests of it as a motor, we carried out cooling down tests and measured its machine constants. During the cooling down tests, we found that the rotor itself had no cryogenic problem, but the inlet part for liquid He had one. Though enough liquid He couldn't be accumulated inside the rotor because of this problem, we drove field currents up to 20 A and could acquire the machine constants and V curves of the super-conducting synchronous motor.

  • PDF

마이크로컴퓨터를 이용(利用)한 엔진 성능시험(性能試験)의 자동화(自動化)에 관한 연구(硏究)(II) -모의(模擬) 부하시험(負荷試験) 시스템의 구성(構成) 및 평가(評價)- (A Microcomputer-Based Data Acquisition/Control System for Engine Performance Test(II) -Construction and Evaluation of a Load Simulation System-)

  • 류관희;배영환;윤기직
    • Journal of Biosystems Engineering
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 1989
  • This study was carried out to develop a system and methodology to simulate the engine load variation occuring during agricultural field operations for a laboratory engine test. The system consisted of an electric dynamometer, an Apple II microcomputer, and a data acquisition and control system. Several pieces of instruments were utilized to measure various engine performance data. Both engine torque and engine speed were fully controlled by a computer program. The dynamic characteristics of the system were analyzed through a series of tests and the limitations on the load simulation test were presented. The results of the study are summarized as follows: 1. Engine speed and toque were controlled by a computer program. The use of a stepping motor and reduction gears enabled engine speed be controlled within 1 rpm. 2. The natural frequency of the dynamometer-engine system was found to be around 5 Hz, at which the load simulation would be impossible because of resonance. 3. For the harmonic inputs with the frequencies above the natural frequency, the signal attenuated too much and therefore the load simulation was impossible. 4. The step response of the system showed an overshoot of 24.5 percent and the settling time for 5 percent criterion was around 3 seconds. 5. When actual field test data are utilized for load simulation, a low-pass filter should be included to attenuate the frequency components around and above the natural frequency.

  • PDF

현장검증시험에 의한 선단변형 PHC말뚝들의 연직하중 지지특성에 관한 연구 (Axial Bearing Characteristics of Tip-transformed PHC Piles through Field Tests)

  • 최용규;김명학
    • 한국지반공학회논문집
    • /
    • 제34권11호
    • /
    • pp.107-119
    • /
    • 2018
  • PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝을 현장 시험 부지에서 시험시공하였다. 이들 선단변형 PHC말뚝들에 대하여 하중전이측정이 수반된 연직압축정재하시험을 실시하였으며 시공직후 항타후 동재하시험을 수행하였다. 또한 선단부만 그라우팅한 선단변형PHC말뚝에 대한 연직압축정재하시험도 실시하였다. 3가지 다양한 선단말뚝들 즉, PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 하중-침하량 거동은 거의 동일한 양상을 나타내었다. 따라서 말뚝이 선단지지층에 근입된 길이가 동일하고 말뚝 본체의 직경이 동일할 경우 확장판 선단부착 PHC말뚝 및 강관 선단부착 PHC말뚝의 지지력 증대 효과는 거의 없는 것으로 나타났다. 최종재하하중단계에서 PHC말뚝, 확장판 선단부착 PHC말뚝, 강관 선단부착 PHC말뚝의 주면마찰력은 각각 전체 재하하중의 95.8%, 95.6%, 97.8%를 분담하였으며, 선단지지력은 전체 재하하중의 4.2%, 4.4%, 2.2%를 분담하였다.

현장 잔존긴장력 평가를 통한 리프트오프 시험 방법 개선 (Improvement of Lift-off Tests via Field Evaluation of Residual Load in Ground Anchor)

  • 송민권;박성열;이상래;조완제
    • 한국지반공학회논문집
    • /
    • 제35권5호
    • /
    • pp.43-51
    • /
    • 2019
  • 현재 국내에서는 비탈면의 안정성 확보를 위해 그라운드 앵커공법을 적용하고 있다. 그라운드 앵커는 시간이 지남에 따라 노후화 및 환경적 영향에 의한 부식, 릴렉세이션, 크립 등으로 긴장력 감소현상이 발생하며, 이로 인해 앵커의 긴장력은 설계앵커력 이하로 감소할 가능성을 내포하고 있다. 이에 국내에서는 정기적인 점검 시 또는 이상 징후가 발생한 앵커를 대상으로 리프트오프 시험을 수행하여 앵커의 잔존긴장력을 확인하고 있으나, 현재 국내 리프트오프 시험기준(국토해양부, 2010)은 수행 및 평가방법이 자세히 명시되어 있지 않은 실정이다. 이에 본 연구에서는 선행연구들을 바탕으로 하중 재하 제하 사이클, 하중 증분방법, 긴장재 긴장 방법 등을 고려하여 리프트오프 시험을 수행하였으며 현장에서의 시공성과 시간적 제한을 고려하여 효율적인 리프트오프 시험 및 평가방법 개선안을 제시하였다.

동재하시험을 통한 긴장력이 도입된 콘크리트 충전 강관말뚝을 사용한 복합말뚝의 연직지지력 평가 (Estimation of Vertical Load Capacity of PCFT Hybrid Composite Piles Using Dynamic Load Tests)

  • 박노원;백규호
    • 한국지반환경공학회 논문집
    • /
    • 제20권3호
    • /
    • pp.31-38
    • /
    • 2019
  • PCFT말뚝의 하부에 PHC말뚝을 연결한 PCFT 복합말뚝에 대한 최적의 동재하시험 분석 방법을 도출하기 위하여 동일 현장에 시공된 강관 복합말뚝과 PCFT 복합말뚝에 대해 동재하시험을 실시한 후 CAPWAP분석 결과를 비교하였다. 그 결과 PCFT 복합말뚝에 대한 동재하시험 수행 시 변형률계와 가속도계는 상부 PCFT말뚝에서 강관을 제거한 후 내부 합성 PHC말뚝에 부착하는 것이 바람직하고, 이렇게 측정된 PCFT 복합말뚝의 입자 변위속도는 PHC말뚝 고유의 변형파 속도인 4,000m/sec과 동일하였다. 그리고 CAPWAP분석 시 PM과정을 통해 상부 PCFT말뚝의 재질을 PHC말뚝과 동일하게 하고 말뚝 단면적으로 콘크리트로 환산한 단면적을 사용했을 때 CAPWAP분석의 정확도가 가장 높은 것으로 나타났다.

송전용 고분자 애자의 정적 및 동적인 상태에서 장기 기계적 특성 연구 (A Study on the Long-term Mechanical Properties Under Static and Cyclic State of Composite Insulators for Transmission Lines)

  • 김수연;김영성;홍진영;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.869-871
    • /
    • 1998
  • The extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. The actual load working on the insulator in the field is not static load but cyclic load. So in this paper, we discussed an examination of aging degradation by mechanical performance of composite insulators under static tension load and cyclic tension load. and also described useful approaches for analyzing their long term performance so as to develop reliable composite insulators. The static and cyclic tension load-time test data were examined by Weibull distribution for their capability of presuming long term performance. It was found that cyclic tension loads were more severe than static tension loads. The results also indicate that it may be relevant for an user to select composite insulators on basis of their performance under cyclic tension loads than static tension loads.

  • PDF