• Title/Summary/Keyword: Field flatness

Search Result 51, Processing Time 0.014 seconds

Comparison between Genetic Algorithm and Simplex Method in the Evaluation of Minimum Zone for Flatness (평면도의 최소 영역 평가에서 유전자 알고리듬과 심플렉스 방법의 비교)

  • Hyun, Chang-Hun;Shin, Snag-Choel
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.27-34
    • /
    • 2000
  • The definition of flatness is given by ISO, ANSI, KS, etc. but those standards don't mention about the specific methods for the flatness. So various solution models that are based on the Minimum Zone Method have been proposed as an optimization problem for the minimax curve fitting. But it has been rare to compare some optimization algorithms to make a guideline for choosing better algorithms in this field. Hence this paper examined and compared Genetic Algorithm and Simplex Method to the evaluation of flatness. As a result, Genetic Algorithm gave the better or equal flatness than Simplex Method but it has the inefficiency caused from the large number of iteration. Therefore, in the future, another researches about alternative algorithms including Hybrid Genetic Algorithm should be achieved to improve the efficiency of Genetic Algorithm for the evaluation of flatness.

  • PDF

A Study on the Scheme to Maintain the Flatness of MDF According by painting and by thickness to the Environment Humidity (습도환경에서 두께와 도장재별 MDF의 평탄도 유지방안에 대한 연구)

  • Jeong, Jae-Eun
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.5
    • /
    • pp.98-106
    • /
    • 2007
  • With the recent increase in the amount of interior materials, the medium-density fiberboard(MDF) has continued to be produced at an increasing rate. Accordingly, to prevent the deformation of MDF after its construction, secure the precision of its finishing and improve the performance of its design, this study attempted to investigate the effect of environment humidity conditions on flatness according to the field used in MDF and its relationship to other physical properties. An attempt was made to conduct this study by changing the conditions of surface treatment by moisture and by thickness. For this purpose, it is judged that it is desirable to prevent scheme to maintain the flatness by defining the coefficient of water absorption-induced length change as in the regulation on low-density soft fiberboard and adjusting the standard for wet bending strength upward. It is thought that is further studies will be conducted about the effect of material, adhesive and thermal pressure condition, production system and processing method used in MDF on its scheme to maintain the flatness and changes in length and thickness expansion.

A Consideration on the Characteristics of Electron Beam Dose Distributions for Clinical Applications (임상적용을 위한 전자선의 선량분포 특성에 대한 고찰)

  • Cha, Dong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2010
  • High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.

  • PDF

Suitability Analysis of Non-contact Sensing Methods for Precast Concrete Element Flatness Inspection (프리캐스트 콘크리트 부재의 평탄도 검사를 위한 센싱 기반 측정방법 적합도 비교)

  • Kwon, Soon-Ho;Kim, Jeong Seop;Sim, Sung-Han;Kim, Minkoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.52-59
    • /
    • 2023
  • Flatness inspection of PC elements is normally conducted manually by inspectors at manufacturing sites. However, the manual inspection is error-prone and subjective, so it is necessary to develop a robust and efficient flatness measurement method. Recently, a few studies of laser scanner-based flatness inspection have been conducted. However, little attention on field applicability in terms of accuracy, time and cost has been paid. To tackle the limitation, this study aims to compare three sensing method including floor profiler, terrestrial laser scanner and total station for flatness inspection of PC elements. A series of experiments on two full-scale PC slabs were conducted and the results show that the laser scanning method is the most suitable for the PC elements flatness inspection in the aspects of accuracy, time and cost.

An Experimental Study on the Swirling Flow Field in the Tangentially Fired Furnace (접선식 배치로내의 선회유동장에 관한 실험적 연구)

  • ;;;Yoon, S. H.;Sim, J. K.;Song, H. B.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3003-3013
    • /
    • 1995
  • The characteristics of the flow field in the tangentially fired furnace are presented. Experiments are conducted in the simplified cold type isothermal flow model. In the measurement of flow field, a hot wire anemometer is used. The hot wire was calibrated by lookup table method. The mean velocity field and turbulence characteristics are showed with changing the nozzle angle. In the center of the model, the low speed, unstable flow region is formed. The size and position of these regions are varied with changing the nozzle angle. It can be used as fundamental data in the design of the large furnace. From the experimental results, various turbulent characteristics of swirling flow field is obtained. And the entrainment mechanism of the jet flow field is described from the distribution of the skewness and the flatness. It can be used the raw data of approximate calculation and turbulent modelling.

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.

Development of Real-time Flatness Measurement System of COF Film using Pneumatic Pressure (공압을 이용한 COF 필름의 실시간 위치 평탄도 측정 시스템 개발)

  • Kim, Yong-Kwan;Kim, JaeHyun;Lee, InHwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2021
  • In this paper, an inspection system has been developed where pneumatic instruments are used to stretch the film using compressed air, thus the curl problem can be overcome. When the pneumatic system is applied, a line scan camera should be used instead of an area camera because the COF surface makes an arc by the air pressure. The distance between the COF and the inspection camera should be kept constant to get a clear image, thus the position of COF is to be monitored on real-time. An operating software has been also developed which is switching on/off the pneumatic system, determining the COF position using a camera vision, displaying the contour of the COF side view, sending self-diagnosis result and etc. The developed system has been examined using the actual roll of COF, which convince that the system can be an effective device to inspect the COF rolls in process.

A Study on Color Reproduction and Flatness of the LED Light Source in Broadcasting Lighting (방송조명에서 LED광원의 색 재현성과 평탄도 연구)

  • Kim, Young-Jin;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.538-551
    • /
    • 2016
  • At the on-site of broadcasting production, the light source of tungsten halogen has been used as a primary light source for representing video images. Although tungsten halogen light has drawn attention in terms of the color reproducibility which is more similar to the sun light than that of other light sources, meanwhile it had problems in energy efficiency. Recently, the LED light source with high efficiency and long lifetime of the energy source has started getting attention as a substitute light source at the broadcast field. Because of the unique light emission principles, compared with tungsten halogen, LED light source has different characteristics in the quality of the light projected from the light source and color reproduction of the video image through a camera. These characteristics cause the delayed introduction of the LED as the broadcast light source. In this study we measured the quality characteristics of the flatness of the color reproduction and light of the LED light source and will present the experimental data whether it is suitable as the broadcasting light source compared to a reference light source of tungsten halogen. In addition, we suggested the future challenges and standards which are needed to expand usage of LED as a broadcast light source.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

A Study on Quality Improvement by Evaluation and Application of GUM-based Measurement Uncertainty (GUM 기반 측정불확도의 평가 및 적용에 의한 품질개선)

  • Insoo Choi;Sun Hur
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.419-434
    • /
    • 2023
  • Purpose: Measurement results obtained under non-ideal measurement environment conditions may contain uncertain factors. As a result, the reliability of measurement results may be deteriorated. In this study, we tried to find ways to improve quality by evaluating and applying measurement uncertainty based on GUM. Methods: In the flatness measurement of semiconductor parts, uncertainty factors that could occur under actual environmental conditions of workers were derived, and measurement uncertainties were calculated, and methods for minimizing the main factors affecting the measurement results were analyzed. Results: Depending on the part and the coordinate measuring machine, it was shown that the effect of dispersion caused by repeated measurements as type A uncertainty and the effect of the calibration results of equipment as type B uncertainty have the main influence. Conclusion: Depending on the uncertainty factors of type A and type B and the influence of the total expanded uncertainty, the central value and confidence interval of the initial measurement results showed fluctuations. It is considered that analysis and measures for the main uncertainty factors are needed as quality improvement in the industrial field.