• Title/Summary/Keyword: Field exposure test

Search Result 161, Processing Time 0.026 seconds

Characteristics of Time Varying Magnetic Fields in Thyristor Rectifiers of 19kA in Chlor-Alkali Industry

  • Shirmohammadi, Siamak;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.383-384
    • /
    • 2014
  • This paper investigates the experimental and simulated time-varying magnetic field generation in a chlor-alkali manufacturing process. 19kA thyristor-based rectifier is modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. The mechanical structure of current carrying conductor is simplified as an infinite long busbar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc busbar of rectifier infringing the limit of ICNIRP. Along with simulation analysis the experimental measurement of the time-varying magnetic field in ac input busbar, rectifier block, dc load and busbar are presented. The experimental test results partly confirm the simulation results.

  • PDF

A Brief Review on Variables and Test Priorities of Photovoltaic Module Life Expectancy

  • Padi, Siva Parvathi;Chowdhury, Sanchari;Zahid, Muhammad Aleem;Kim, Jaeun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.9 no.2
    • /
    • pp.36-44
    • /
    • 2021
  • To endorse the reliability and durability of the solar photovoltaic (PV) device several tests were conducted before exposing to the outdoor field in a non-ideal condition. The PV module has high probability that intend to perform adequately for 30 years under operating conditions. To evaluate the long term performance of the PV module in diversified terrestrial conditions, one should use the outdoor performance data. However, no one wants to wait for 25 years to determine the module reliability. The accelerating stress tests performing in the laboratory by mimicking different field conditions are thus important to understand the performance of a PV module. In this review, we will discuss briefly about different accelerating stress types, levels and prioritization that are used to evaluate the PV module reliability and durability before using them in real field.

Field Exposure Test of the Concrete Treated by Protective Surface Coatings in Marine Environment (표면도장재를 적용한 콘크리트의 해양 노출시험)

  • 정해문;유환구;안태송
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.71-76
    • /
    • 2002
  • 콘크리트는 거의 반영구적인 재료라고 인식되어져 왔으나, 최근들어 해양환경, 적설한랭지대, 도심과 같은 열악한 환경속에서 예상보다 빨리 조기열화 되는 현상이 널리 알려지면서 콘크리트 구조물의 구조적 성능뿐만 아니라, 장기적인 내구성에 대한 관심이 높아져 가고 있다. 실제로 여러 선진국에서 염해와 같은 열화환경의 피해를 받은 콘크리트 구조물이 예상공용년수 이전에 철거되거나. 개보수 비용이 초기 건설비용보다 더 많이 드는 예가 적지 않게 보고되면서, 적절한 내구성 유지대책 및 구조물의 장수명화를 위해 많은 연구와 노력이 진행되고 있다.(중략)

A Study on the Quality Characteristics of Leather Shoe Adhesives(I) -Ladies' Leather-shoe- (구두용 접착제의 품질 특성에 관한 연구(I) -여성 가죽구두-)

  • 서교택;이상신
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.54
    • /
    • pp.137-144
    • /
    • 2000
  • The chloroprene adhesive for ladies' shoe-making applied by the cementing method in KS G 3116 has been evaluated.. For the quality test of adhesive for pump whole cut vamp using chloroprene adhesive, general property and adhesion strength were measured and duration for environmental exposure was tested. Also, a list of experiments for field application was prepared. In case of adhesion-strength measurement,, the KS G 3116 method of peel strength at end of toe was found to be reasonable by measurement through a whole length, toe to heel seat on feather edge.

  • PDF

Study on Corrosion of Automotive Coil Spring Steel by Electrochemical Impedance Spectroscopy (전기화학 임피던스 분석을 통한 자동차용 코일스프링 강의 부식 평가)

  • Lee, Kyu Hyuk;Park, Jung-Hyun;Ahn, Seung Ho;Seo, Ji Won;Jang, HeeJin
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.298-304
    • /
    • 2017
  • Coil spring steels from the automobile suspension part after field exposure for 10 years and those after anti-corrosion validation test in proving ground of 5,000 ~ 10,000 km were examined for corrosion damages. Partial loss of paint, accumulation of corrosion product, and cracking of paint and superficial material were observed. The surface and subsurface region of spring steels had compressive residual stress and high hardness by shot peening. The surface hardness values of the specimens were 620 ~ 670 Hv. They were 60 ~ 80 Hv higher than those of the samples taken from the middle part of the spring. The maximum compressive stress was -916 ~ -1208 MPa measured at depth of about $100{\mu}m$. Electrochemical impedance spectroscopy showed that the resistances of charge transfer and the paint layer of the spring steels ranged from several tens to millions ${\Omega}{\cdot}cm^2$. The resistance of the field samples was much higher than that of the proving ground samples used in this study, implying that the proving ground test condition would be more corrosive than the field environment.

Mutation Frequency of Tradescantia (BNL Clone 4430) Stamen Hairs Exposed to Low Dose of Gamma Ray in the KAERI ${\gamma}$-Field (저선량율의 감마선 조사에 의한 자주 달개비의 체세포 돌연변이 출현에 관한 연구)

  • Shin Han Kwon;Young Il Lee;Kyu Hoi Chung;Jeung Haing Oh
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.161-167
    • /
    • 1981
  • For determination of mutation frequency induced by chronic irradiation of low dose gamma rays, Tradescarrfia clone 4430 was exposed to Co-60 ${\gamma}$ rays with different exposure rates from 3.6mR/day to 182R/day in or out of the Gamma Field at Kumkok Experiment Farm of KAERI. Somatic mutations based on pink mutant events of the stamen hair cells were clearly observed by the treatment. The pink mutant events were increased proportionally with increasing exposure rates of gamma ray except for relatively high dose rates of 105 R/day and 182 R/day, indicating saturation effect of mutation. The somatic pink mutations could be fairly detectable even in the low dose rate of 3.6mR/day. Therefore, this stamen hair system of Tradescantia clone 4430 seemed to be an reasonable test system for detecting mutability of low level irradiation. These results imply that artificial mutation induction in the fruit and ornamental trees could be expected in the ${\gamma}$-field.

  • PDF

Accelerated Weathering Test of Urethane Paint for Heavy Construction Equipment (중장비용 우레탄 도료 내후성 가속시험)

  • 김대용;김영준
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.79-93
    • /
    • 2001
  • Recently, new aspects of paints such as a beautiful appearance, use of environmentally friendly paints, etc., in addition to the superior performance of paints have been requested for industrial paints including the paints for heavy construction equipment and others. Particularly, the quality of appearance of coating affects the sales of heavy construction equipment. And the necessity for the paints to have a superior weather-proof property without changing the luster or color even after long-time exposure to the open air is emphasized. The change in the surface color and luster of the paint due to the natural environment progresses very slowly, and it takes a long time to verify material properties when developing new paints. In order to improve such methods, weathering tests are performed in many laboratories as a test for accelerating aging of coating, and the lifetime of the products is estimated through evaluation of the weathering (environment-proof) quality of paints. However, not a great deal of research activity has been conducted up to the present time since the interrelationship between the actual results of testing and field data is different for each paint and it takes a long time to study relevant materials. Therefore, introduced in the present study is the estimation of the change in the quality of appearance of coating in the field through the accelerated aging test among the cases of improvement of the quality of appearance of the urethane paint for heavy construction equipment.

  • PDF

Weatherability Assessment of Nonwoven Geotextiles by Field Exposure Test (현장노출시험에 의한 부직포 지오텍스타일의 내후성 평가)

  • Jeon, Han-Yong;Yuu, Jung Jo;Kim, Young Yoon;Byun, Sung Weon;Byun, Sung Weon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.37-42
    • /
    • 2004
  • In the reinforced retaining wall system, non-woven geotextiles are placed at the face of reinforced earth until the facing blocks are built up. And when this system is used as temporary structure, geotextiles facings are exposed to sunlight during service lifetime. During these periods, degradation of nonwoven geotextiles are occurred by UV light. So the UV-resistance of nonwoven geotextiles must be assessed correctly, in considering of the site conditions. In this study, laboratory test and the field test have been performed to evaluate the UV resistance of non-woven geotextiles used in KOESWall system and the results are expressed in terms of tensile characteristics & SEM photographs.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Evaluation of Corrosion Thickness Loss of Temporary Steel Members Exposed to A Subway Construction Site (지하철 공사현장 환경하의 가시설 강재의 부식두께감소량 추정)

  • Kim, In Tae;Jeon, Sang Hyuck;Hur, Jung Ok;Cheung, Jin Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.301-310
    • /
    • 2009
  • Steel has been widely used as a material in temporary structures. Corrosion attack often reduces the long-term durability of temporary steel members that are not protected from corrosion. In designing temporary steel structures, it is difficult to evaluate their long-term durability, since the thickness loss of steel members is not clear. In this study, laboratory and field exposure corrosion tests were performed on structural steel plate specimens, and the loss of thickness of specimens that were exposed to a subway construction site for 11 months and of specimens that were exposed to environments with controlled humidity and calcium chloride for six months were measured. Finally, a thickness loss equation was formulated based on the environmental conditions and the testing periods.