• Title/Summary/Keyword: Field Intensity Factors

Search Result 194, Processing Time 0.031 seconds

Anti-Plane Shear Behavior of an Arbitrarily Oriented Crack in Bonded Materials with a Nonhomogeneous Interfacial Zone

  • Chung, Yong-Moon;Kim, Chul;Park, Hyung-Jip
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.269-279
    • /
    • 2003
  • The anti-plane shear problem of bonded elastic materials containing a crack at an arbitrary angle to the graded interfacial zone is investigated in this paper The interfacial zone is modeled as a nonhomogeneous interlayer of finite thickness with the continuously varying shear modulus between the two dissimilar, homogeneous half-planes. Formulation of the crack problem is based upon the use of the Fourier integral transform method and the coordinate transformations of basic field variables. The resulting Cauchy-type singular integral equation is solved numerically to provide the values of mode 111 stress intensity factors. A comprehensive parametric study is then presented of the influence of crack obliquity on the stress intensity factors for different crack size and locations and for different material combinations, in conjunction with the material nonhomogeneity within the graded interfacial zone.

Study on the Stress Singularity of Interface Crack by using Boundary Element Method (경계요소법을 이용한 계면균열의 응력특이성에 관한 고찰)

  • Cho, Chong-Du;Kwahk, Si-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.197-204
    • /
    • 1999
  • The boundary element method was used for studying singularities of an interface crack with contact zones. The iterative procedure is applied to estimate the contact zone size. Because the contact zone size was extremely small in a tension field, a large number of Gaussian points were used for numerical integration of the Kernels. Stress extrapolation method and J-integral were used ofr determining stress intensity factors. When the interface crack was assumed to have opened tips, oscillatory singularities appear near the tips of the interface crack. But the interface crack with contact zone which Comninou suggested had no oscillatory behavior. The contact zone size under shear loading was much larger than that under tensile. The stress intensity factors computed by stress extrapolation method were close to those of Comninou's solution. And the stress intensity factor evaluated by J-integral was similar to that by stress extrapolation method.

  • PDF

Probabilistic analysis of gust factors and turbulence intensities of measured tropical cyclones

  • Tianyou Tao;Zao Jin;Hao Wang
    • Wind and Structures
    • /
    • v.38 no.4
    • /
    • pp.309-323
    • /
    • 2024
  • The gust factor and turbulence intensity are two crucial parameters that characterize the properties of turbulence. In tropical cyclones (TCs), these parameters exhibit significant variability, yet there is a lack of established formulas to account for their probabilistic characteristics with consideration of their inherent connection. On this condition, a probabilistic analysis of gust factors and turbulence intensities of TCs is conducted based on fourteen sets of wind data collected at the Sutong Cable-stayed Bridge site. Initially, the turbulence intensities and gust factors of recorded data are computed, followed by an analysis of their probability densities across different ranges categorized by mean wind speed. The Gaussian, lognormal, and generalized extreme value (GEV) distributions are employed to fit the measured probability densities, with subsequent evaluation of their effectiveness. The Gumbel distribution, which is a specific instance of the GEV distribution, has been identified as an optimal choice for probabilistic characterizations of turbulence intensity and gust factor in TCs. The corresponding empirical models are then established through curve fitting. By utilizing the Gumbel distribution as a template, the nexus between the probability density functions of turbulence intensity and gust factor is built, leading to the development of a generalized probabilistic model that statistically describe turbulence intensity and gust factor in TCs. Finally, these empirical models are validated using measured data and compared with suggestions recommended by specifications.

Effect of Electric Fields on Crack Kinking in Ferroelectrics (전기장이 강유전체 내의 균열킹크에 미치는 영향)

  • Lee, Jong-Sik;Beom, Hyeon-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1206-1210
    • /
    • 2003
  • Effect of transverse electric field on crack kinking in ferroelectric ceramics subjected to purely electric loading is investigated. It is shown that the shape and size of the domain switching zone depends strongly on the direction of the applied electric field as well as the ratio of the transverse electric field to the coercive electric field. Under small-scale conditions, mode I and II stress intensity factors induced by ferroelectric domain switching are numerically obtained. The crack kinking in ferroelectrics is also discussed.

  • PDF

An Analysis on the Structure of Meaning for Amenities of Sound Environment II -Psychological Evaluation Factors and Attributes of Noise- (음환경의 쾌적성에 관한 의미구조의 분석 II -소음의 심리적 평가요인과 속성-)

  • 한명호;김선우
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.706-714
    • /
    • 1998
  • The purpose of this study is to analyse the main factors and attributes of psychological evaluation to noise. For this purpose, a psycho-acustic experiment was conducted by using the method of rating scale. 52 subjects were participated in the experiment, 20 stimuli were presented to subjects in random order with 23 adjectives. As a result of factor analysis, it was found that the primary factors for evaluating the quality of noise subjectively are four factors of unpleasantness, intensity, irregularity, and sharpness. And, as a result of MDPREF(multi-dimensional analysis of preference data), it was found that the noise sources including the factors of unpleasantness, intensity, and irregularity are related to the sounds of hammering in construction field, car horn, road traffic, idling of car, and printing by computer printer, and the factor of sharpness are the sounds of car siren, claps of thunder, car horn, and snowstorm etc.

  • PDF

Seral Changes in Environmental Factors and Recovery of Soil Fertility during Abandoned Field Succession after Shifting Cultivation (회전 후 묵밭의 식생 천이 진행에 따른 환경요인의 변화와 토양 비옥도의 회복)

  • Lee, Kyu Song;Joon-Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.18 no.2
    • /
    • pp.243-253
    • /
    • 1995
  • Seral changes in environmental factors and recovery of soil fertility during abandoned field succession after shifting cultivation were investigated in eastern Kangwon-Do, Korea. Relative light intensity of herb and shrub layer decreased gradually until 50 years and increased slightly thereafter. Amount of litter and nutrients derived from it were depicted as a parabola form showing the gradual increment during the first 50 years and slight decrease thereafter. Organic matter, pH value, total-N and Mg of soil were plotted as an early depletion-mid pinnacle form showing the extrems depletion during the first 10 years, abrupt increase in about 20 or 50 years and gradual decrease thereafter. Ca, Al, Mn and Na of soil were depicted as a pinnacle form showing the peak in about 20 or 50 years. Thickness and field capacity of soil increased gradually, but K and total-P did not show any tendency as succession proceeded. The soil fertility, overall capacity of soil nutrients and water for plant growth, was plotted as the early depletion-mid pinnacle form.

  • PDF

Calculation of weight functions in single edge notched specimen (SEN시편에서의 무게함수 계산)

  • 안득만
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.604-610
    • /
    • 1991
  • In this paper, the weight functions for the Mode I and Mode II in SEN(single edge notched) specimen are obtained by superposition of the displacement in the singular field of the Buckner type and the displacements by opposite tractions induced by the singular field. The stress intensity factors, $K_{I}$ and $K_{II}$ are calculated by the weight function theory in SEN specimen under the loading equivalent to uniform tension and shear at infinity in Griffith crack. And the results are compared with the exact solutions.s.

Effect of Transverse Electric Fields on Fracture Behavior of Ferroelectric Ceramics (횡전기장이 강유전체 세라믹의 파괴거동에 미치는 영향)

  • Lee Jong Sik;Beom Hyeon Gyu;Jeong Kyoung Moon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.120-125
    • /
    • 2005
  • Effect of transverse electric fields on fracture behavior in ferroelectric ceramics under purely electrical loading is investigated. It is shown that the shape and size of the domain switching zone depend strongly on the ratio of the transverse electric field to the coercive electric field as well as the direction of the applied electric field. Under small-scale conditions, the crack-tip mode I and II stress intensity factors induced by ferroelectric domain switching are numerically obtained. The crack kinking in ferroelectric ceramics is also discussed.

A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses (고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

Temperature and Electric Field Effect on Proton Transfer in Adenine-thymine

  • Zhang, Guiqing;Xie, Shijie
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3532-3534
    • /
    • 2014
  • In theoretical simulations of proton transfer in DNA, environmental factors nearly have not been considered. In our calculations, using QM/MM method on the basis of CP2K, proton transfer on adenine-thymine base pair is studied in water, at wide scope temperature, and under the external electric field. Our results indicate that the external electric field induces the proton transfer at room temperature, and its intensity and temperature have some effect on hole localization and proton transfer.