• Title/Summary/Keyword: Field Installation

Search Result 1,199, Processing Time 0.027 seconds

옥외 태양광 발전 시스템의 Potential Induced Degradation 진단 및 야간 역전압 회복 연구

  • Choe, Hun-Ju;Kim, Gwang-Hyeon;Jang, Dong-Sik;Bae, Su-Hyeon;Park, No-Chang;O, Won-Uk
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.3 no.2
    • /
    • pp.42-47
    • /
    • 2017
  • The potential induced degradation (PID) phenomenon shows severe power loss within several years from the initial installation of solar power system. The accumulated power loss by PID is inevitable because the PID is suspected only if the power loss exceeds several percent. In this paper, we analyzed the cases of PID diagnosis and recovery by visiting the suspected PID site about 17 months after the installation of the 100kW PV system. The power difference of the two 50kW inverters was more than 20kWh, and the PR difference was more than 8%. From the beginning of the installation, the difference in power gradually increased. The recovery was observed for about 7 months by applying 1000V in the reverse bias at night. As a result, the power difference of the two inverters was recovered to within 2kWh. In the case of a power station suffering from PID in the field, it will be helpful for stable development operation by quick diagnosis and problem solving.

  • PDF

Design and A Safety Analysis and Assessment of a Grounding System according to International Standards (국제 표준(IEC)에 의한 접지 설계 및 이에 대한 안전성 분석·평가)

  • Kim, Doo-Ung;Cho, Man-Hyung;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.54-59
    • /
    • 2015
  • In this paper, we evaluate safety of grounding system which is designed according to IEC standards. Safety assessment of construction site and grounding system of building is needed before construction for the safety of human in building. Until now, in case of domestic field, design of grounding system is proceeded based on methods which are proposed in IEEE Std. 80. In other words, it is not in the situation that grounding system is designed based on IEC standards. Therefore, we propose a method which designs grounding system and evaluates safety of it according to IEC standards. We measure ground resistance of construction site using measuring equipment of ground resistance. Using this value, soil structure and ground resistivity are obtained through program analysis. CDEGS program of SES company is used for simulation analysis.

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

Characteristics and Measurement Method of the Underwater Electromagnetic Signature Emitted from a Naval Ship (함정 발생 수중 전자기장 신호의 특성 및 측정 기법)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.11-19
    • /
    • 2006
  • The underwater electromagnetic signatures of a naval ship are mainly generated from three sources which are the permanent and induced magnetic field in the ship's hull and other ferrous components, the cathodic current electromagnetic field established by the Impressed Current Cathodic Protection(ICCP) system or the Sacrificial Anode and the stray electromagnetic fields generated by onboard equipment. These signatures can be minimized by certain design methods or installation of signature reduction equipment. In this paper, we represented the characteristic of the underwater electromagnetic signature and the signature reduction techniques for a naval ship. Also, we measured the electromagnetic field changes emitted from the real ship using the Electric and Magnetic field Measurement System(EMMS). We found that the underwater electromagnetic signature for a naval ship can be used as input or trigger signal in a surveillance system and an influence mine.

Development of Radar Beam Steering Measurement System and measurement Boresight Error (레이다 빔조향 특성 측정 장치 개발 및 보어 사이트 에러 측정)

  • Yong-kil Kwak
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.546-551
    • /
    • 2023
  • In this study, a beam steering measurement system was developed to perform functions such as far-field beam steering and near-field beam focusing for TX/RX modes in the near file of the AESA radar. The beam steering measurement system consists of a spherical near-field scanner, an antenna positioner, a near-field controller, a network analyzer, a radar control system, a verification radar, a simulated radio, and an AESA radar. Using the developed system, the characteristics of TX/RX patterns before and after installation of radome to AESA radar were measured, and the beam pattern was analyzed through conversion to far field-after near-field measurement.The boresight error of the radar antenna device was measured, and it was confirmed that the main lobes were formed the same before and after the simulated radar dome was mounted.

Biogas Purifying for Fuel cell Power Plant (연료전지 발전을 위한 바이오가스정제)

  • Lee, Jong-Gyu;Jun, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.439-444
    • /
    • 2007
  • Using the anaerobic digester gas as a fuel, fuel cells have the potential to provide significant environmental and economic benefits. A molten carbonate fuel cell power plant was installed in the municipal sewage works of Tancheon in Seoul. The fuel cell unit operates on anaerobic digester gas and provides power and heat for the sewage works. This is the first project of its kind in Korea. This article outlines the experiences of gas purification process with planning, installation and operation. The engineering and installation phase is described regarding to the special features of digester gas, for example impurities in gas composition. Such impurities would be harmful to fuel cells. Operational results from the field test with a gas purification process plant are presented in this paper.

Measurement and Analysis of Magnetic Field Waveform Generated by Operating Fluorescent Lamp (형광등의 사용중에 발생되는 자계파형의 측정과 해석)

  • 이복희;전덕규;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.22-29
    • /
    • 1994
  • 본 논문에서는 시변자계측정을 위한 센서와 형광등의 점등에 의하여 발생되는 자계의 특성에 대하여 기술하였다. 자계측정계는 동축케이블을 사용한 자기적분형 자계센서와 증폭기, 적분기로 구성하였으며 교정실험 결과, 주파수대역은 약 40Hz∼100kHz이었다. 수동점등식, 고주파점등식과 글로우점등식 등 여러 가지 점등방식의 형광등에 의하여 발생되는 자계의 파형을 측정하고, 측정된 자계의 주파수성분을 고속푸리에변환(fast Fourier transformation: FFT)기법으로 해석하였다. 형광등의 점등중에 발생되는 자계성분은 주로 기수고주파 성분이 많이 포함되어 있으며, 인덕션칵에 의하여 점등순간에는 급변성의 과도성분이 나타났다. 전자회로나 제어기기의 보호를 위한 자계차폐장치를 설계할 때에는 반드시 자계의 기수고조파성분을 고려하여야 됨이 확인되었다.

  • PDF

A Study on Stabilization of Multi-Excited Induction Motor (다중여자 유도전동기의 안정도에 관한 연구)

  • 강만원;김한성
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.78-85
    • /
    • 1995
  • This paper covers stability and stabilization of Multi-Excited Induction Motor used in numberous electric equipment system of industrial field. The induction motor with multi-excitation has tow sets of three-phase system : One is connected to the AC source to supply most power required at the load, and the other is to the inverter for variable frequency and/or magnitude of voltage. The conventional induction motor is operated under single excitation mode only, that is called induction mode. But in multi-excited induction motor both the induction mode and the synchronous mode are possible, and the proposed multi-excited induction motor can be driven as a synchronous motor by the extra three-phase input. At the synchronous mode the efficiency is improved so higher than that at induction mode or conventional induction motor. The rating of the inverter used for speed control of numberous electric equipment system can be reduced upto one-tenth of that for conventional induction motor. Also the cost and maintenance fee of multi-excited induction motor can be reduced compared to any other motor.

  • PDF

Numerical Calculation of Longitudinal Current Distribution in Grounding Electrode for Analyzing the Grounding Impedance (접지임피던스 분석을 위한 접지전극의 전류분포 수치계산)

  • Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • The current distribution passing through grounding electrode is required for calculating an impedance of grounding electrode using the electromagnetic field model. In this paper the numerical calculation for currents passing through a grounding electrode as a function of frequency was given. The proposed approach is based on the wire antenna model(AM) in the frequency domain. The Pocklington's equation driven from the wire antenna theory was numerically calculated by the Galerkin's method. The triangle function was applied to both the basis function and the weighting function. The current distribution of a horizontal ground electrode was simulated in MATLAB. Also these results were compared with the data obtained from the CDEGS HIFREQ calculation.