• 제목/요약/키워드: Fiber reinforced-composite post

검색결과 61건 처리시간 0.021초

154kV급 Hollow Composite Insulator의 기계적 강도해석 및 특성시험 (The Performance Test and Mechanical Strength Analysis for 154kV Hollow Composite Insulator)

  • 박기호;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.495-498
    • /
    • 2002
  • This paper describes the results the problem of stress calculation and optimization into a FRP(Fiber-glass Reinforced Plastic) tube crimped into a metal end-fitting. This type of assembly is used mainly is used mainly for suspension and line post insulators. Fitting strength of FRP and flange of this study is required greatly from composite insulator to important special quality. Therefore, wish to seek analysis and mechanical strength performance that follow to FRP tube and flange of top and bottom mechanical fitting.

  • PDF

An approach to a novel modelling of structural reinforced glass beams in modern material components

  • Foti, Dora;Carnimeo, Leonarda;Lerna, Michela;Sabba, Maria Francesca
    • Advances in Computational Design
    • /
    • 제7권3호
    • /
    • pp.173-188
    • /
    • 2022
  • In modern buildings, glass is considered a structurally unsafe material due to its brittleness and unpredictable failure behavior. The possible use of structural glass elements (i.e., floors, beams and columns) is generally prevented by its poor tensile strength and a frequent occurrence of brittle failures. In this study an innovative modelling based on an equivalent thickness concept of laminated glass beam reinforced with FRP (Fiber Reinforced Polymer) composite material and of glass plates punched is presented. In particular, the novel numerical modelling applied to an embedding Carbon FRP-rod in the interlayer of a laminated structural glass beam is considered in order to increase both its failure strength, together with its post-failure strength and ductility. The proposed equivalent modelling of different specimens enables us to carefully evaluate the effects of this reinforcement. Both the responses of the reinforced beam and un-reinforced one are evaluated, and the corresponding results are compared and discussed. A novel equivalent modelling for reinforced glass beams using FRP composites is presented for FEM analyses in modern material components and proved estimations of the expected performance are provided. Moreover, the new suggested numerical analysis is also applied to laminated glass plates with wide holes at both ends for the technological reasons necessary to connect a glass beam to a structure. Obtained results are compared with an integer specimen. Experimental considerations are reported.

섬유보강 고인성 시멘트 복합체 패널의 2축 전단 비선형 모델 (Nonlinear Biaxial Shear Model for Fiber-Reinforced Cementitious Composite Panels)

  • 조창근;김윤용
    • 한국전산구조공학회논문집
    • /
    • 제22권6호
    • /
    • pp.597-605
    • /
    • 2009
  • 본 연구에서는 철근 보강된 Engineered Cementitious Composite(ECC) 면내요소에 대한 2축응력 상태에서의 면내전단거동에 관한 예측 모델을 제시하였다. 기존의 철근콘크리트와 상이한 특성, 즉 ECC 요소의 복수미세균열 현상에 의한 높은 연성의 인장 거동, 일반 콘크리트에 비하여 연성적인 압축 연화 거동, 그리고 ECC 균열면에서의 전단전달 거동 특성 등을 모델에 반영하였다. 면내 순수전단거동에 대한 실험 및 해석결과를 통하여 개발된 R-ECC-MCFT 모델은 ECC 면내전단거동 예측에 효과적인 것으로 평가되었다. 또한 철근 보강된 ECC 면내요소는 철근콘크리트 면내요소에 비하여 최대전단강도 및 전단변형률이 증가하기 때문에 면내전단변형에서 높은 연성을 확보하는 것으로 평가되었다.

Effects of deficiency location on CFRP strengthening of steel CHS short columns

  • Shahabi, Razieh;Narmashiri, Kambiz
    • Steel and Composite Structures
    • /
    • 제28권3호
    • /
    • pp.267-278
    • /
    • 2018
  • Structures may need retrofitting as a result of design and calculation errors, lack of proper implementation, post-construction change in use, damages due to accidental loads, corrosion and changes introduced in new editions of construction codes. Retrofitting helps to compensate weakness and increase the service life. Fiber Reinforced Polymer (FRP) is a modern material for retrofitting steel elements. This study aims to investigate the effect of deficiency location on the axial behavior of compressive elements of Circular Hollow Section (CHS) steel short columns. The deficiencies located vertically or horizontally at the middle or bottom of the element. A total of 43 control column and those with deficiencies were investigated in the ABAQUS software. Only 9 of them tested in the laboratory. The results indicated that the deficiencies had a significant effect on the increase in axial deformation, rupture in deficiency zone (local buckling), and decrease in ductility and bearing capacity. The damages of steel columns were responsible for resistance and stiffness drop at deficiency zone. Horizontal deficiency at the middle and vertical deficiency at the bottom of the steel columns were found to be the most critical. Using Carbon Fiber Reinforced Polymer (CFRP) as the most effective material in retrofitting the damaged columns, significantly helped the increase in resistance and rupture control around the deficiency zone.

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

섬유 강화형 포스트를 이용한 치관 파절된 치아의 재부착: 증례보고 (Management of complicated crown fracture by tooth fragment reattachment with fiber post: a case report)

  • 김유리;정경화;손성애;박정길
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.251-258
    • /
    • 2021
  • 치아 외상은 어린이와 비교적 젊은 연령에서 흔히 발생하며 외상 발생 시점, 환자의 나이, 치아의 성숙 상태 등이 치료 방법에 영향을 미친다. 약 파절편이 건전하고 잔존 치아와 밀접한 적합을 보일 경우, 파절편 재부착은 유용한 치료 옵션이 될 수 있다. 이 방법은 치아 본래의 형태와 교합의 회복뿐만 아니라 기능, 표면 광택과 질감을 그대로 재현할 수 있는 여러 가지 이점이 있다. 본 증례보고는 복잡 치관 파절된 치아를 섬유 강화형 포스트를 활용하여 파절편 재부착을 시행한 두 증례에 대해 소개한다.

탄소섬유/에폭시 복합적층판에 대한 저온에서의 기계적특성 실험평가 (Experimental Evaluation of Mechanical Properties for the Carbon/Epoxy Composite Laminates at Low Temperature)

  • 허남일;사정우;조승연;도철진;오영국;최창호;권면;이경수;이상연;김재훈
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.41-44
    • /
    • 2001
  • Mechanical test of the Carbon Fiber Reinforced Plastics (CFRP) composite specimen was performed based on the ASTM code at the ambient and low temperature. Tension, compression in-plane shear, and inter-laminar shear properties of the composite laminates were evaluated experimentally using the Universal Testing Machine(UTM) system at the temperature of $24^{\circ}C$,$-76^{\circ}C$ , and $-196^{\circ}C$. From the test results it was found that the CFRP chosen for the Korea Superconducting Tokamak Advanced Research(KSTAR) magnet supporting post had smaller tensile strength and larger compressive strength at the low temperature than those of the ambient temperature because of material ductility.

  • PDF

The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement

  • Tuncdemir, Ali Riza;Yildirim, Cihan;Ozcan, Erhan;Polat, Serdar
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.457-463
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P> .05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.

Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가 (Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post)

  • 박하은;이철원;이원섭;양성은;이수영
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.127-133
    • /
    • 2019
  • 목적: 본 연구의 목적은 주조 금속 포스트, 기성 섬유강화형 포스트 그리고 치과영역에서 새롭게 주목 받고 있는 재료인 polyetherketoneketone(PEKK)으로 제작한 포스트로 수복된 근관 치료 치아의 파절 강도 및 파절 양상에 대해 조사하는 것이다. 재료 및 방법: 총 21개의 하악 소구치를 포스트 재료에 따라 각각 7개씩 3개의 군으로 무작위로 분류하였다. 그룹 A는 주조 금속 포스트 코어; 그룹 B는 기성 섬유강화형 포스트 및 레진 코어; 그룹 C는 밀링된 PEKK 포스트 코어로 수복하였다. 모든 시편은 금속관으로 수복하였다. 각각의 시편들을 제작 후 만능 시험기를 사용하여 2 mm/min 속도로 치아 장축에 대해 135도의 정적 하중을 가하여 파절 강도를 측정하고, 파절 양상에 대해 조사하였다. 결과 분석은 유의수준 ${\alpha}=.05$에서 Kruskal-Wallis test 후 사후검정으로 Mann-Whitney U test를 시행하였다. 결과: PEKK 포스트 파절 강도는 주조 금속 포스트와 기성 섬유강화형 포스트에 비해 낮은 값을 보였다. 파절양상에 있어서는 육안과 현미경, 방사선 사진을 통해 살펴본 결과 금속 포스트 코어에서는 치근파절의 양상이 대부분 나타난 반면 기성 섬유 강화형포스트는 포스트의 탈락이 주로 발생하였다. PEKK 포스트 코어의 경우 치아와 포스트가 함께 파절되는 양상이 주로 나타났다. 결론: 치관부 치질이 심하게 손상된 치아 수복 시 적절한 재료의 선택이 필요하며, PEKK 포스트의 임상적 적용을 위해서는 강도 향상에 대한 연구가 더 필요할 것으로 보인다.

패키지형 탄소섬유복합재 가공시스템 개발 (Development of Manufacturing System Package for CFRP Machining)

  • 김효영;김태곤;이석우;윤한솔;경대수;최인휴;최현;고종민
    • 한국정밀공학회지
    • /
    • 제33권6호
    • /
    • pp.431-438
    • /
    • 2016
  • Recently, concerns about the environment are becoming more important because of global warming and the exhaustion of earth's resources. In the aviation and automobile industries, the application of light materials is increasingly important for eco-friendly and effective. Carbon Fiber Reinforced Plastics is a composite material which great formability and the high strength of carbon fiber. CFRP, which is both light and strong, is hard to manufacture. In addition, CFRP machining has a high chance of defects. This research discusses the development of a manufacturing system package for CFRP machining. It involving CFRP Drilling/Water-jet Manufacturing Machines, Inspection/Post-processing Systems, CNC platform for an EtherCAT servo Communication, Flexible Manufacturing Systems and CFRP machining Processes.