• 제목/요약/키워드: Femoral prosthesis

검색결과 33건 처리시간 0.032초

Adaptive Postural Control for Trans-Femoral Prostheses Based on Neural Networks and EMG Signals

  • Lee Ju-Won;Lee Gun-Ki
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.37-44
    • /
    • 2005
  • Gait control capacity for most trans-femoral prostheses is significantly different from that of a normal person, and training is required for a long period of time in order for a patient to walk properly. People become easily tired when wearing a prosthesis or orthosis for a long period typically because the gait angle cannot be smoothly adjusted during wearing. Therefore, to improve the gait control problems of a trans-femoral prosthesis, the proper gait angle is estimated through surface EMG(electromyogram) signals on a normal leg, then the gait posture which the trans-femoral prosthesis should take is calculated in the neural network, which learns the gait kinetics on the basis of the normal leg's gait angle. Based on this predicted angle, a postural control method is proposed and tested adaptively following the patient's gait habit based on the predicted angle. In this study, the gait angle prediction showed accuracy of over $97\%$, and the posture control capacity of over $90\%$.

Management of Severe Bone Defects in Femoral Revision following Total Hip Arthroplasty

  • Yicheng Li;Li Cao
    • Hip & pelvis
    • /
    • 제36권2호
    • /
    • pp.101-107
    • /
    • 2024
  • Treatment of femoral bone defects continues to be a challenge in revision total hip arthroplasty (THA); therefore, meticulous preoperative evaluation of patients and surgical planning are required. This review provides a concise synopsis of the etiology, classification, treatment strategy, and prosthesis selection in relation to femoral bone loss in revision THA. A search of literature was conducted for identification of research articles related to classification of bone loss, management of femoral revision, and comparison of different types of stems. Findings of a thorough review of the included articles were as follows: (1) the Paprosky classification system is used most often when defining femoral bone loss, (2) a primary-length fully coated monoblock femoral component is recommended for treatment of types I or II bone defects, (3) use of an extensively porous-coated stem and a modular fluted tapered stem is recommended for management of types III or IV bone defects, and (4) use of an impaction grafting technique is another option for improvement of bone stock, and allograft prosthesis composite and proximal femoral replacement can be applied by experienced surgeons, in selected cases, as a final salvage solution. Stems with a tapered design are gradually replacing components with a cylindrical design as the first choice for femoral revision; however, further confirmation regarding the advantages and disadvantages of modular and nonmodular stems will be required through conduct of higher-level comparative studies.

Duromedics 승모판막의 판엽파손 (Duromedics Mitral Valve Leaflet Escape)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • 제25권7호
    • /
    • pp.750-755
    • /
    • 1992
  • We report a case of leaflet embolization of central leaflet fracture a 31mm mitral Edw-ards-Duromedics prosthesis. A leaflet was fractured to two segments, a larger one embolized to right common iliac artery and a smaller one to left femoral artery, respectively. Patient was reoperated with 29mm mitral Carbomedics prosthesis and incidentally found of smaller segment in left femoral artery at cannulation site. The embolectomy was done 15 days after cardiac operation through midline abdominal incision, Leaflet escape of a mitral Edward-Duromedics prosthesis is a rare, potentially curable mode of valve failure. After mechanical valve replacement, unexplained heart failure and acute pulmonary edema, mechanical valve failure should be suspected. Correct interpretation of clinical signs, symptoms and fluroscopy should allow early diagnosis of leaflet escape and prompt surgical therapy.

  • PDF

무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성 (Biomechanical characteristics of the distal filling effects in cementless femoral stem)

  • 박상석;박재원;채수원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

양 표재성대퇴정맥을 이용한 복부 인조혈관 감염증 치험 1예 (A Case of Surgical Treatment of the Abdominal Aortic Graft Infection with Bilateral Superficial Femoral Vein)

  • 우종수;방정희;조광조
    • Journal of Chest Surgery
    • /
    • 제37권10호
    • /
    • pp.880-883
    • /
    • 2004
  • 복부 인조혈관 감염증은 매우 심각한 상태로서 문합부 파열로 심한 출혈이나 급성 말초 색전증으로 하지 허혈을 유발하여 사망률이 높고 치료하기 어려운 질환으로 치료에 대한 논란이 많은 질환이다. 저자는 복부대동맥류 수술 후 약 1년 후에 발생한 인조혈관 감염증례를 양 허벅지 심부정맥인 표제성 대퇴정맥을 사용하여 재치환하여 좋은 결과를 얻었기에 문헌과 함께 보고한다.

Numerical simulation of the total hip prosthesis under static and dynamic loading (for three activities)

  • Mohammed El Sallah Zagane;Abdelmadjid Moulgada;Murat Yaylaci;Sahli Abderahmen;Mehmet Emin Ozdemir;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.635-645
    • /
    • 2023
  • This study aims to simulate the mechanical behavior of the total prosthesis model of Charnley (CMK3) by the 3D finite element method and to determine the state of the stresses in the femoral components (prosthesis, cement, and bone). The components are subjected to a dynamic load due to three activities (normal walking, climbing stairs, and standing up a chair). Static loading is by selecting the maximum load for the same activities mentioned. The results show that the maximum stresses in the proximal part of the cement are very important. Moreover, new results obtained for different parameters were discussed in detail. It is understood that current research provides important lessons for the surgeon to contribute to the clinical diagnosis of durable implantations and a better understanding of the process of bone remodeling and bone prosthesis.

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • 제35권4호
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

대퇴부 거동 해석 및 복합재료 보철물 설계 (Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis)

  • 임종완;하성규
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권2호
    • /
    • pp.119-130
    • /
    • 2002
  • 무시멘트 인공 고관절 전치환술 후, 복합재료 스템을 갖는 대퇴골의 장기 거동과 인공 대퇴 보철물의 설계 성능을 분석하기 위하여 비선형 유한요소 프로그램이 개발되었다. 한 발로 서 있을 때의 관절 접촉 하중과 근육하중이 적용되었고, 816개의 brick요소를 갖는 타원형 단면의 복합재료 스템으로 치환된 대퇴골이 3차원 유한요소로 모델링 되었다. 프로그램을 사용하여 대퇴골의 밀도 변화, 응력분포, 상대미소운동이 plate cut과 bend mold와 같은 제작 방법에 대한 스템의 적층 각도 변경에 따라서 평가되었다. 결과는 코발트 크롭 합금, 티타늄 합금, 스테인레스 강과 같은 금속 재료보다 AS4/PEEK, T300/976과 같은 복합재료가 적은 골 흡수를 보였다. 대퇴골 보철물의 장기 안정성 증대는 적당한 복합재료의 적층과 적층 각도의 선택에 의하여 얻어질 수 있었다.

무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구 (A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM)

  • 김성곤;채수원;최형연
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF

감염된 종양 대치물 제거와 하지 단축 보정 후 시행한 사지 구제술 - 증례 보고 - (Limb Salvage Surgery after Removal of Infected Tumor Prosthesis with Equalization of Leg Length)

  • 권영호;김재도;정소학;조율
    • 대한골관절종양학회지
    • /
    • 제12권2호
    • /
    • pp.141-147
    • /
    • 2006
  • 좌측 대퇴골 원위부 골육종 진단 받은 9세 여아로 광범위 절제수술과 재활용 자가골 이식술을 받은 후 하지 부동과 성장판 손상이 있어 확장형 종양 대치물로 치환수술을 시행하였다. 그 후 종양 대치물에 심부 감염 발생하여 종양 대치물 제거 후 감염을 조절하기 위한 시멘트와 골수내정을 이용한 한시적 공간 대치물을 삽입하였다. 감염이 조절된 후 외고정 장치를 이용한 하지 부동(10 cm)에 대한 교정을 시행하였고, 마지막으로 종양 대치물 재삽입을 통한 관절 기능 보존을 시행한 1례를 보고 하고자 한다.

  • PDF