• Title/Summary/Keyword: Femoral fixation

Search Result 92, Processing Time 0.027 seconds

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Slipped Capital Femoral Epiphysis(SCFE) (대퇴골두 골단분리증의 치험례)

  • Dan, Jin-Myoung;Kim, Se-Dong
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.245-261
    • /
    • 1997
  • Slipped capital femoral epiphysis(SCFE) is a disorder in which there is a gradual or acute disruption through the capital physeal plate. The physiolysis is through a widened zone of hypertrophy, which is weakened due to altered chondrocytic maturation and endochondral ossification. The cause or causes of SCFE remain uncertain. The association of obesity and adolescent age with growth rate are predisposing factors. The possibility that most patients with subclinical hormonal abnormality were proved. The goal of treatment of slipped capital femoral epiphysis is to restore the function of the hip and delay the development of degenerative osteoarthrosis by prevention of additional displacement of the epiphysis. We report 10 patients(12hips) with SCFE who were treated by surgical means and followed along for more than one year, at Yeungnam University Hospital, from 1989 to 1996. There were six boys and four girls. The average age at operation was 11.8 years. Seven cases occurred in the left hip, one case in the right and 2 cases had bilateral involvement, five cases had a history of minor trauma on affected hip. Among hormonally studied six patients, panhypopituitarism patient was one case; decreased testosterone, two; decreased growth hormone, two; and decreased thyroid hormone, one. According to clinical stage, two cases were the acute type; five cases, acute on chronic type; and three cases, chronic type. On the radiological grades of slipping, mild slippage were nine hips; moderate, one; and severe, two. The eleven hips were treated by pin fixation in situ, and one, by cuneiform osteotomy. On the average follow-up of 2.6 years, ten hips were excellent or good functional results, two hips were failure.

  • PDF

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.

Effects of Intramedullary K-wire Insertion on Femoral Lengthening in Canine with Monolateral External Fixator (단측성 외고정 기구를 이용한 개의 대퇴골 신연에 있어서 골수강내 K-강선 삽입의 효과)

  • Hwang, Jae-Min;Kim, Young-Ki;Chin, Hee-Tec;Seok, Seong-Hoon;Lee, Hee-Chun;Koh, Phil-Ok;Chang, Hong-Hee;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.291-299
    • /
    • 2006
  • During long bone lengthening, there are many disadvantages including axial deviation, malalignment and re-fracture which are commonly encountered inspite of its proven abilities. To study the effects of intramedullary K-wire application on the lengthening of long bone, ten skeletally mature mongrel dogs were separated into two groups(Group I, II). Right femurs of group I(5 dogs) were fixed with only monolateral external fixator after subperiosteal osteotomy. Right femurs of group II(5 dogs) were fixed with mono lateral external fixator and intramedullary K-wire after subperiosteal osteotomy. Lengthening was started at 7 days after the surgery with the rate of 0.5 mm per day for 5 weeks and the dogs were sacrificed after 15 weeks postoperatively to examine histologic differences and evaluate bone mineral density. Radiographic examination at an interval of two weeks was done to evaluate the type of callus formed and to analyze complications including instability of external skeletal fixation and axial deviation. Bone mineral density at the lengthened area and contralateral nonlengthened area were measured using quantitative computerized tomography. Histological examination of regenerated bone was performed using Masson's trichrome stain method. The radiographs demonstrated poor callus formation, higher incidence of axial deviation and screw loosening in the group I compared to the group II. The bone mineral density at the lengthened area in the group II was higher than that of the group I(P<0.05). Histological examination showed that the new bone trabeculae in the group II were greater than that of the group I. In conclusion, the combination of monolateral external fixator and intramedullary K-wire can prevent pin loosening, axial deviation and reduce healing period in dogs.

Meniscus Repair using Meniscus Arrow with Anterior Cruciate Ligament Reconstruction (전방 십자 인대 재건술시 동반된 반월상 연골 파열에 대한 meniscus arrow를 이용한 봉합)

  • Cho Sung-Do;Park Tae-Woo;Hwang Su-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.156-160
    • /
    • 2002
  • Purpose : To evaluate the results and usefulness of meniscal repair using meniscal arrows with ACL reconstruction. Material and Methods : Among cases of the simultaneous meniscal arrow fixation and ACL recontruction performed between May, 1997 and September, 2000, 17 cases could be evaluated. The average follow-up were 18.5 months. Twelve cases were medial meniscus, 5 cases, lateral meniscus. All cases were longitudinal tear. Meniscal tear were seen at red-red zone in 13 cases, red-white zone in 5 cases. The results were analyzed by pain, joint line tenderness, locking, McMurray test, the Marshall knee scoring scale and complications. Results : Postoperatively two patients had mild joint line tenderness without pain on joint motion or weight bearing. No patient had locking or positive McMurray test. At last follow-up, 15 cases $(88\%)$ were 'excellent' or 'good' according to the Marshall knee score scale. There were two complications which are soft tissue irritation sign on active knee motion and a femoral chondral injury due to protruded T-shaped head of meniscus arrow. Conclusion : Meniscus arrow can be one of the options in repairing the associated meniscus tear, especially the posterior horn of medial meniscus, during ACL reconstruction. However, surgeons using meniscus arrow should be aware of its potential complications such as pain due to soft tissue irritation and chondral damage of the femoral condyle.

  • PDF

Potential Seizurogenic Effect of Tramadol in a Dog with Necrotizing Meningoencephalitis (괴사성 뇌척수막염을 가진 진돗개에서 Tramadol에 의한 잠재적 경련발생 증례)

  • Kim, Se-Hun;Heo, Su-Young;Lee, Ki-Chang;Lee, Hae-Beom;Kim, Nam-Soo;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.323-327
    • /
    • 2011
  • A Jindo dog (8-month-old, intact male) was referred for hind limb lameness on the right side. The dog was diagnosed with a simple femoral fracture by radiological examination. After surgical fixation of the femoral fracture, tramadol: a narcotic-like synthetic analgesic was intravenously administrated for post-operative analgesia. After injection of the tramadol, generalized tonic clonic seizure was immediately occurred in the dog. Seventeen hours later, the dog died despite intensive care. We suspected that tramadol might induce the seizurogenic effect resulted in death. A necropsy was performed to examine the cause of the death. In consequence, the dog was diagnosed as necrotizing meningoencephalitis (NME) based on histopathological examination. We would be concerned that tramadol may be related to seizure activity in the NME patient. From this case, it is known that although tramadol has been proven to be a safe and effective agent for the control of pain in veterinary medicine, it would be carefully used to patient with history of neurological diseases including meningoencephalitis, hydrocephalus, and encephalopathy.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

Comparison of Anterior Cruciate Ligament Reconstructions Using Hamstring Tendon Autograft and Tibialis Tendon Allograft (자가 슬괵건 및 동종 경골건을 이용한 전방 십자 인대 재건술의 결과 비교)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Bae, Bong-Hyun;Park, Sang-Jin;Kim, Jong-Seon;Lee, Dam-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • Purpose: To compare the clinical and radiological results of anterior cruciate ligament(ACL) reconstruction using hamstring autograft and tibialis tendon allograft. Materials and Methods: Twenty four ACL reconstructions using hamstring autograft and 30 using tibialis anterior tendon altograft were followed up at least 1 year. We performed femoral tunnel fixation with Ligament Anchor(LA) screw and tibial tunnel fixation with biodegradable interference screw. Evaluations included Lysholm knee(LK) score, Tegner activity scale, Lachman test, Pivot-Shift test, Quardriceps atrophy, incision site numbness, anterior knee pain and instrumented anterior laxity with $Telos^{(R)}$ device. Results: Preoperativ mean LK score was $60.3(18{\sim}82)$ in autograft group and 61.2(25-80) in allograft group. Mean LK score improved to $91.6(68{\sim}100)\;and\;92.6(77{\sim}100)$ respectively. Activity level, using Tegner activity scale, slightly decreased compared with that of Preinjury state in both groups. Lachman test, pivot-shift test, Quadriceps atrophy, anterior knee pain, incision site numbness, and anterior drawer test using $Telos^{(R)}$ device showed no significant difference between two groups (p>0.05). Conclusion: In performing the ACL reconstruction, there was no statistically significant difference between hamstring autograft group and tibilis anterior allograft group in clinical or in radiological results.

  • PDF

Significance of tibial intra-tunnel fixation at Arthroscopic ACL Reconstruction with hamstring tendon (Second-look Arthroscopic Evalution) (자가 슬괵건을 이용한 전방 십자인대 재건술시 경골측 골 터널내 고정의 의의 (이차관절경 검사의 평가))

  • Kim, Young-Chang ;Seo, Seung-Suk;Jung, Kyung-Chil;Gwak, Hey-Chul;Kim, Yoon-Jun;Kim, Jin-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 2006
  • Purpose: The purpose of this study is to evaluate the effects of intratunnel fixation in the tibial side on the arthroscopic ACL reconstruction with quadruple hamstring tendon at the second look arthroscopy. Materials and Method: From Dec 1999 to May 2005, we arthroscopically reexamined 32 cases who had been done arthroscopic ACL reconstruction with quadruple hamstring tendons. Hamstring tendons of all cases were fixed at femoral side with RigidfixTM. At the tibial side hamstring tendons were fixed only Post-tie (Group I) or Post-tie combined with IntrafixTM (Group II). At the time of second look arthroscopy mean age of cases was 30 years and mean duration for second look arthroscopy was 21.3 months. We analyzed the results with IKDC score, KT-1000 arthrometer under anesthesia, Telos stress radiography, tibial tunnel widening on the radiography and second look arthroscopic findings. Results: Group II had more superior than group I at side to side differences with KT-1000 and Telos stress radiograph, IKDC score, but the differences were insignificant. At arthroscopic evaluation, Group ll also had more superior than group I at graft tension and graft appearance, graft synovialization, but the differences were insignificant. Tibial tunnel widening in the knee AP radiograph was 2.3 mm in Group I and 1.7 mm in Group II and the difference was significant. (P=0.042) Conclusions: Additional procedure of tibial intratunnel fixation in arthroscopic ACL reconstruction with autogenous hamstring tendon significantly prohibited from tibial tunnel widening but clinical results, radiologic joint stability, findings in second look arthroscopy were insignificantly different. We concluded that Post-tie itself induced satisfactory clinical results, joint stability and graft maturation and that tibial tunnel widening did not affect the results.

  • PDF

Surgical Treatment of Metastatic Bone Tumor in Extremity (사지에서 전이성 골종양의 수술적 치료)

  • Lee, Han-Koo;Lee, Sang-Hoon;Baek, Goo-Hyun;Lee, Chang-Seop
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.45-51
    • /
    • 1995
  • The incidence of metastatic bony lesion has been increased recently, with the advanced therapeutic modalities of malignant tumors. The purpose of this study was to evaluate the effectiveness of surgical treatment in impending or established pathologic fractures due to metastasis in extremity. From 1981 to 1992, thirty two patients who had established or impending pathologic fractures in extremity had been treated surgically. The locations of metastasis, were lower extremity in 24 cases(femsral head and neck;5, intertrochanteric;7, subtrochanteric;8, femoral shaft;4) and upper extremity in 8 cases(proximal humerus;2, humoral shaft;6). The method of surgery was excision of tumor mass and rigid internal fixation to allow immediate mobilization, except 2 cases of amputation. The results were analysed by two criteria. The first was the grade of performance status that was made by modification of Functional Classification of New York Heart Association. The second was the degree of pain relief. The performance status was improved at least one grade in all patients and the mean improvement was 1.7 grades. The satisfactory pain relief was achieved in 81% of patients. Postoperatively, most of the patients had only slight to moderate limitation of physical activities and they became comfortable at rest and ordinary activities. The solitary metastatic lesions showed better pain relief(92%) than multiple metastasis(75%). The curative surgery was done in 3 cases, and they showed more than 24 months of disease-free survival.

  • PDF