• Title/Summary/Keyword: Feeder Automation System

Search Result 66, Processing Time 0.025 seconds

An Algorithm on Optimal Placement Decision of Automatic Switches for 6 Sections/3 Links Configuration in DAS

  • Lim, Il-Hyung;Zhang, Wen-Hao;Trirohadi, Hamsyah;Choi, Myeon-Song;Lee, Seung-Jae;Ha, Bok-Nam
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.328-333
    • /
    • 2011
  • A Distribution Automation System (DAS) is operated by monitoring and control of the field statesusing Feeder Remote Terminal Units (FRTUs) installed together withautomatic switches.An optimal placement of automatic switchescan enhanceefficiencyof the operation and restoration, and improve the power supply reliability ofa DAS.This paper proposes an algorithm to decide the optimal placement of automatic switches ina DAS.The proposed algorithm was developed ona DAS witha six sections and three links configuration. The proposed algorithm was provided inaneight-feeder power distribution system.

Distribution Automation System in KEPCO (한전의 배전자동화)

  • 장영주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.7-10
    • /
    • 2001
  • Distribution Automation System (DAS) has been designed and implemented for feeder automation using the Paircable, Optical-Fiber, Wireless, TRS as a communication media. KEPCO has been constructed DAS since 1984. We have two types of DAS. one is large-scale DAS for major city in korea, the other is small-scale DAS (or the rest of major city. we are plan to finish small-scale DAS by end of 2001.

  • PDF

An expert system approach to the type selection of part feeders (부품공급장치 선정을 위한 전문가 시스템)

  • 조덕영;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.296-301
    • /
    • 1989
  • As a cornerstone of assembly automation, the automatic part feeders are used to feed the various kind of the parts to the assembly workstation in the desired order and fashion. In this paper, EXPERT SYSTEM consisting of the data base for the feeding functions and part properties plus the rule base for the selection of feeder types is developed. The symbolic data of the part properties are used as basic factors in the selection rule of the suitable feeder types.

  • PDF

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

A Study of the Terminal Developement for Distribution Automation System (배전 자동화용 단말장치 기술 개발및 전원 구성에 관한 연구)

  • Kye, Moon-Ho;Kim, Jong-Soo;Jung, Je-Wook;Nam, Hyo-Sung;Park, Jong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.902-904
    • /
    • 1993
  • This paper contains the terminal developement for the feeder remote unit in Korea Distribution Automation System. This terminal unit has serval functions in order to do feeder auotmation as following, the open/close controls and gathering status informations of switchgears, getting line currents and voltages, distribution fault. So FRU has four modules to do those functions-Logic Controller, Relay Controller, Data Acquisition, Display, Power Supply etc. The FRU should be on allays, so AC power is supplied before & behind the switchgear. Power Supply is made up with AC/DC, DC/DC, Battery and/or SOLAR CELLS & CONTROLLER. It is important for the supply to protect against some Surges, because surges are happened so many times. Surge test is fellowing the standard IEC 801-5 or IEEE 587.

  • PDF

Development of a management control system for KODAS (KODAS 관리제어 시스템 개발)

  • Kim, K.H.;Nam, K.Y.;Kim, W.T.;Seo, J.I.;Ko, H.J.;Lee, J.K.;Yyun, T.Y.;Kim, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.424-426
    • /
    • 1993
  • Main function of distribution automation system can be summarized as feeder automation, telemetering, load control and facility information management. But in most cases, one or two of the above mentioned functions are developed in one distribution automation system. Which function to be developed in the automation system depends on the distribution system's characteristics. The title KODAS means $\underline{KO}$rea $\underline{D}$istribution $\underline{A}$utomation $\underline{S}$ystem. Management Korea for KODAS is central control station of distribution system, which is composed of several substations. This paper describes computer system, software tools, data base design data acqusition scheme and information flow.

  • PDF

The Conception and Function of the MMI(Man Machine Interface) Software In the Distribution Automation System (배전자동차용 MMI 프로그램 설계 개념 및 기능)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho;Lim, Seong-Ii;Seo, Jeong-Il;Lu, Jong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.303-305
    • /
    • 1999
  • This paper introduces the MMI software for Central Control System in the Distribution Automation System. It provides remote monitoring and real-time control of distribution through the use of remote terminal units(RTUs) graphically. Our MMI software for distribution automation displays a circuit operating map based on the distribution automation database, and overlays it with outage information from the feeder Automation software.

  • PDF

Analysis of Distribution Line Sectionalizing Effects for The Probable Distribution System Configuration (적정 배전계통 구성을 위한 선로분할 효과 분석)

  • Kim, J.H.;Ha, B.N.;Nam, K.Y.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.86-89
    • /
    • 1993
  • This paper contains the various effect of distribution feeder sectionalizing by distribution automation. The effect by automatic sectionalizing switch and the effect by manual switch are analyzed and shown according to the radial feeder and the loop feeder respectively. Based on the reliability analysis, the reference for the feeder division and sectionalization is recommended. Also, the necessary number of manual switch where the automatic switch is installed is recommended through the reliability analysis.

  • PDF

The Standard for Installation of Automated Distribution Switch-gear in Multi-Line Faults (다중선로 고장을 고려한 배전자동화용 개폐기 설치기준)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun;Lim, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1079-1081
    • /
    • 1999
  • This paper presents the standard for dividing/tieing the distribution lines and installing optimally the automated distribution switch-gear in multi-line faults. Also this paper recommends the distribution system design in consideration of the live load transfer of the concentrated load in the last load-side. This recommendation will be useful for designing the distribution network, developing the feeder automation software and operating the distribution automation system.

  • PDF

Distribution Automation Switch Testing Software Development (배전자동화용 개폐기 시험용 소프트웨어 개발)

  • Ok, Ki-Jung;Kim, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.446-448
    • /
    • 2001
  • We have developed the testing software for KEPCO operators to maintain the small-scale distribution automation system effectively. The testing software is used to monitor the present status, to measure the analog value(voltage, amperage) and to control the switch and FRTU(Feeder Remote Terminal Unit) in order to find out a disabled part of the system. And at the stage of inspection of the switch and FRTU, it can screen the inferior one.

  • PDF