• 제목/요약/키워드: Fault current limiting operations

검색결과 19건 처리시간 0.034초

피크전류제한 기능을 갖는 초전도한류기의 전류제한 특성분석 (Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.47-51
    • /
    • 2011
  • The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

이중퀜치를 이용한 삼상변압기형 한류기의 고장전류제한 동작 분석 (Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench)

  • 한태희;고석철;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.184-189
    • /
    • 2022
  • In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.

사고전류 제한형 고온 초전도케이블의 통전부 특성평가 (Evaluation on the Properties of the Current Transporting Part for Fault-Current-Limiting Type HTS Cables)

  • 김태민;홍공현;한병성;두호익
    • 한국전기전자재료학회논문지
    • /
    • 제27권10호
    • /
    • pp.657-661
    • /
    • 2014
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through high-Tc superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate method to protect it. The fault-current-limiting type HTS cable that is suggested in this study has a structure of transport part and limit part. It conduct a zero impedance transport current at ordinary operations and carry out a fault current limiting at extraordinary operations. To make a perfect this structure, it is essential to investigate electrical properties of transport part that comprise the fault-current-limiting type HTS cable. In this paper, transport part that comprise HTS wire with copper stabilization layer is examined the current transport properties and the stability evaluation.

사고전류 제한형 초전도케이블 제작을 위한 초전도 선재 선정에 관한 연구 (Study on Selection of HTS Wire for Fabrication of Fault Current-limiting Type HTS Cables)

  • 허성욱;김태민;한병성;두호익
    • 한국전기전자재료학회논문지
    • /
    • 제26권12호
    • /
    • pp.904-908
    • /
    • 2013
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through a high-capacity and high-$T_c$ superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate measure to protect it. Therefore, appropriate measures are needed to protect HTS cables. The fault-current-limiting HTS cable that was suggested in this study performs an ideal transport current function in normal operations and plays a role in limiting a fault current in abnormal operation (i.e., when a fault current is applied). It has a structure that facilitated its self-current-limiting ability through device change and reconfiguration in the existing HTS cable without extra switching equipment. To complete this structure, it is essential to investigate about the selection of the superconducting wire. Therefore, in this paper, HTS wire using two types of different stabilization layer is compared and examined the stability and current limiting properties under the existence of a fault current.

Study on Current Limiting Characteristics of a Flux-locktype SFCL using Series Connected Two Coils with Twice Triggering Operation

  • Han, Tae-Hee;Ko, Seok-Cheol;Lee, Byongjun;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.777-781
    • /
    • 2014
  • The current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using series connected two coils with twice triggering operation, which consists of series connected two coils and two superconducting (SC) modules with the inserting resistance, was analyzed. The feature of the suggested SFCL is that it can limit the fault current by triggering either one SC module or two SC modules comprising the SFCL depending on the amplitude of the fault current. To verify the current limiting operation of the suggested SFCL, the short-circuits in the fault location with the different fault currents were tested and its useful operations were described through the analysis on the tested results.

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

자속 구속형 전류제한기의 사고각에 따른 초기 사고전류 제한 시점 변화분석 (Variations of Initial Fault Current Limiting Instant According to Fault Angles in the Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.61-64
    • /
    • 2004
  • In this paper, we investigated the variations of initial fault current limiting instant according to fault angles in the flux-lock type SFCL. The flux-lock type SFCL consists of the coil 1 and the coil 2 that are wound in parallel each other through an iron core. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The subtractive polarity winding operation could be analyzed with three modes. On the other hand, the additive polarity winding operation could be analyzed with five modes. The variations of initial fault current limiting instant in two winding directions were dependent on the fault angles. It was confirmed from experiment that the fault current limiting instant was getting faster and the magnitude of fault current at the initial fault time was getting higher for higher fault angle.

  • PDF

모의전력계통에 적용된 자속구속형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of a Fault-lock Type SFCL Applied into a Simulated Power System)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.141-146
    • /
    • 2011
  • When the current of the superconducting element exceeds its critical current by the fault occurrence, the quench of the high-$T_C$ superconducting fault current limiter (HTSC) comprising the flux-lock type superconducting fault current limiter (SFCL) occurs. Simultaneously, the magnetic flux in the iron core induces the voltage in each coil, which contributes to limit the fault current. In this paper, the fault current limiting characteristics of the flux-lock type SFCL as well as the load voltage sag suppressing characteristics according to the flux-lock type SFCL's winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the flux-lock type SFCL were carried out. The flux-lock type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag suppressing operations through the fast quench occurrence right after the fault occurs and the fast recovery operation after the fault removes than the flux-lock type SFCL designed with the subtractive polarity winding.

모의전력계통에 적용된 두 개의 자기결합 회로를 갖는 직렬연결형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of Series Connection-type SFCL with Two Magnetically Coupled Circuits Applied into a Simulated Power System)

  • 고석철;이신원
    • 한국전기전자재료학회논문지
    • /
    • 제26권1호
    • /
    • pp.68-72
    • /
    • 2013
  • The series connection-type superconducting fault current limiter (SFCL) with two magnetically coupled circuits was suggested and its effectiveness through the analysis on the current limiting and recovery characteristics was described. The fault current limiting characteristics of the proposed SFCL as well as the load voltage sag compensating characteristics according to the winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the series connection-type SFCL were carried out. The series connection-type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag compensating operations through the fast quench occurrence right after the fault appears and the fast recovery operation after the fault removes than that with the subtractive polarity winding.

이중퀜치를 이용한 자속구속형 초전도한류기의 과도전류제한 특성 (Transient Current Limiting Characteristics of Flux-Lock Type SFCL Using Double Quench)

  • 최상재;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.96-100
    • /
    • 2017
  • In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two $high-T_{c}$ superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both $0^{\circ}$ and $90^{\circ}$ fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.