• 제목/요약/키워드: Fault cores

검색결과 30건 처리시간 0.028초

Fault-tolerant Scheduling of Real-time Tasks with Energy Efficiency on Lightly Loaded Multicore Processors

  • Lee, Wan Yeon;Choi, Yun-Seok
    • International journal of advanced smart convergence
    • /
    • 제7권3호
    • /
    • pp.92-100
    • /
    • 2018
  • In this paper, we propose a fault-tolerant scheduling scheme with energy efficiency for real-time periodic tasks on DVFS-enabled multicore processors. The scheme provides the tolerance of a permanent fault with the primary-backup task model. Also the scheme reduces the energy consumption of real-time tasks with the fully overlapped execution between each primary task and its backup task, whereas most of previous methods tried to minimize the overlapped execution between the two tasks. In order to the leakage energy loss of idle cores, the scheme activates a part of available cores with rarely used cores powered off. Evaluation results show that the proposed scheme saves up to 82% energy consumption of the previous method.

단층핵의 물리적 특성과 마찰 특성의 상관관계 분석 (Physical Properties and Friction Characteristics of Fault Cores in South Korea)

  • 문성우;윤현석;서용석
    • 자원환경지질
    • /
    • 제53권1호
    • /
    • pp.71-85
    • /
    • 2020
  • 본 연구에서는 지반공학 및 지질공학적 측면에서 단층핵의 거동을 이해하기 위해 화강암, 퇴적암 및 화산암 단층대에서 채취된 단층핵 시료를 대상으로 물리적 특성(각력 및 점토함량, 단위중량, 공극률, 함수비)과 마찰 특성(내부마찰각, 점착력)의 관계를 분석하였다. 실내시험으로부터 산정된 물리적 특성을 분석한 결과, 단층핵 내 각력은 단위중량과 양(+)의 상관관계를 가지고, 점토함량, 공극률 및 함수비와는 음(-)의 상관관계를 가진다. 직접전단시험으로부터 산정된 내부 마찰각과 점착력에 대한 사분위수 범위(IQR)는 각각 16.7-38.1°, 2.5-25.3 kPa로 나타났다. 또한, 단층핵의 마찰특성에 미치는 물리적 특성의 영향을 분석한 결과, 마찰각은 모든 암종에서 각각 각력함량 및 단위중량과 양(+)의 상관관계를 가지고, 점토함량, 공극률 및 함수비와 음(-)의 상관관계를 보인다. 대조적으로, 단층핵의 점착력은 각력함량 및 단위중량과 음(-)의 상관관계를 가지고, 점토함량, 공극률 및 함수비와 양(+)의 상관관계를 보인다.

두 개의 자속경로를 갖는 직렬연결형 초전도한류기의 이중 피크전류제한 특성 (Double Peak Current Limiting Properties of Series Connection-Type SFCL with Two Magnetic Paths)

  • 고석철;한태희;임성훈
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.62-68
    • /
    • 2014
  • We proposed a series connection-type superconducting fault current limiter(SFCL) using E-I core that can prevent the internal magnetic flux generation of cores during normal operation, and prevent the saturation of cores due to a sudden magnetic flux generation at the initial stage of fault occurrence while limiting the peak current. Through a short-circuit simulation experiment, we analyzed the operating status of the two superconducting elements and limiting characteristics according to the size of the fault current peak before and after the failure. Further, the double peak current limiting characteristics according to the winding directions as well as the current and the voltage of each coil were compared and analyzed.

자기베어링의 Fault Tolerance 제어 (Fault Tolerant Control of Magnetic Bearings)

  • Na, Uhn-Joo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.342.2-342
    • /
    • 2002
  • Fault tolerant control algorithm fer heteropolar magnetic bearings are presented. This fault tolerant control utilizes grouping of currents as C-cores in order to isolate magnetic fluxes. Hardware requirements to maintain fault tolerant control are reduced since decoupling chokes are not required in this control scheme. The currents supplied to each pole are redistributed, if some coils (ail suddenly, such that the resultant magnetic forces should remain invariant through coil failure events. (omitted)

  • PDF

한반도 동남부 백악기 경상분지 내 영덕단층의 기하와 운동학적 특성 (Geometry and Kinematics of the Yeongdeok Fault in the Cretaceous Gyeongsang Basin, SE Korea)

  • 서경한;하상민;이성준;강희철;손문
    • 암석학회지
    • /
    • 제28권3호
    • /
    • pp.171-193
    • /
    • 2019
  • 이번 연구는 영덕군 일원의 상세 지표조사를 통해 양산단층의 가지단층인 영덕단층의 내부 구조와 기하를 파악하고, 주변 퇴적층의 자세, 단층의 운동학적 자료와 단층암의 자기미세구조 분석을 통해 영덕단층의 운동학적 특성을 규명하는데 목적이 있다. 음영기복도에서 총 40 km의 연장을 보이는 영덕단층은 트라이아스기 영덕화강암, 백악기 퇴적암과 화산암을 절단하며 약 8.1 km의 우수향 수평변위를 보인다. 주로 북북서 내지 남-북 방향으로 발달하는 영덕단층은 영덕읍 화천리 이북에서 하나의 단층선으로 달리지만, 화천리 이남에서는 두 조의 단층대로 분기되는 특징을 보인다. 이들 두 조의 단층 중 서편의 것은 북북동 내지 북동 방향과 북북서 방향의 단층분절들이 지그재그 형태로 연결되는 반면, 동편의 것은 북북서 방향의 하나의 단층으로 연장되다가 영덕군 강구면에서 양산단층과 합쳐진다. 영덕단층은 대부분 지점에서 $65^{\circ}$ 이상의 고경사로 동쪽으로 경사하며, 2~15 m 폭의 단층핵과 최대 180 m 폭의 단층손상대를 가진다. 단층핵은 퇴적암류, 화산암류, 화강암 등 여러 모암으로부터 유래된 단층암으로 구성되며, 이들은 모암에 따라 뚜렷한 변형의 차이를 보인다. 화강암에서 유래된 단층핵은 주로 단층각력으로 구성되며, 10 cm 이내 폭의 단층비지대에 전단변형이 집중된다. 반면, 퇴적암에서 유래된 단층핵은 화강암의 것에 비해 두꺼우며 단층비지대와 각력대가 교호하거나 렌즈상의 모암을 단층비지대가 에워싸며 발달한다. 단층대와 인접한 퇴적층의 자세는 주 단층면과 가까워지면 단층면의 자세와 유사하게 고각으로 경동된다. 단층활면 및 전단단열에서 관찰된 운동 자료와 단층암의 대자율이방성 분석결과는 영덕단층이 북서-남동 방향 최대수평응력 하에서 좌수향 주향이동운동을 겪은 이후 북동-남서 방향 최대수평응력 하에서 우수향 주향이동운동을 겪었으며, 우수향 주향이동운동에 의한 변형 특성이 우세하게 기록되어 있다. 이번 연구를 통해 얻어진 영덕단층의 운동사를 기존 양산단층의 운동사와 비교해본 결과, 두 단층의 주향이 다소 차이가 있음에도 불구하고 백악기 말의 북서-남동 방향 최대수평응력과 고제3기의 북동-남서 방향 최대수평응력 하에서 각각 좌수향과 우수향 주향이동의 동일한 감각으로 운동한 것으로 판단된다.

Fault Tolerant Control of Magnetic Bearings

  • Na Uhn-Joo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.388-392
    • /
    • 2002
  • Fault tolerant control algorithm for heteropolar magnetic bearings are presented. This fault tolerant control utilizes grouping of currents as C-cores in order to isolate magnetic fluxes. Hardware requirements to maintain fault tolerant control are reduced since decoupling chokes are not required in this control scheme. The currents supplied to each pole are redistributed, if some coils fail suddenly, such that the resultant magnetic forces should remain invariant through coil failure events. Load capacity before magnetic saturation is reduced through coil failures while maintaining the same magnetic forces before and after failure.

  • PDF

Seismic performance evaluation of steel moment resisting frames with mid-span rigid rocking cores

  • Ali Akbari;Ali Massumi;Mark Grigorian
    • Steel and Composite Structures
    • /
    • 제46권5호
    • /
    • pp.621-635
    • /
    • 2023
  • The combination of replaceable and repairable properties in structures has introduced new approach called "Low Damage Design Structures". These structural systems are designed in such a way that through self-centering, primary members and specific connections neither suffer damage nor experience permanent deformations after being exposed to severe earthquakes. The purpose of this study is the seismic assessment of steel moment resisting frames with the aid of rigid rocking cores. To this end, three steel moment resisting frames of 4-, 8-, and 12-story buildings with and without rocking cores were developed. The nonlinear static analysis and incremental dynamic analysis were performed by considering the effects of the vertical and horizontal components of 16 strong ground motions, including far-fault and near-fault arrays. The results reveal that rocking systems benefit from better seismic performance and energy dissipation compared to moment resisting frames and thus structures experience a lower level of damage under higher intensity measures. The analyses show that the interstory drift in structures equipped with stiff rocking cores is more uniform in static and dynamic analyses. A uniform interstory drift distribution leads to a uniform distribution of the bending moment and a reduction in the structure's total weight and future maintenance costs.

40-TFLOPS artificial intelligence processor with function-safe programmable many-cores for ISO26262 ASIL-D

  • Han, Jinho;Choi, Minseok;Kwon, Youngsu
    • ETRI Journal
    • /
    • 제42권4호
    • /
    • pp.468-479
    • /
    • 2020
  • The proposed AI processor architecture has high throughput for accelerating the neural network and reduces the external memory bandwidth required for processing the neural network. For achieving high throughput, the proposed super thread core (STC) includes 128 × 128 nano cores operating at the clock frequency of 1.2 GHz. The function-safe architecture is proposed for a fault-tolerance system such as an electronics system for autonomous cars. The general-purpose processor (GPP) core is integrated with STC for controlling the STC and processing the AI algorithm. It has a self-recovering cache and dynamic lockstep function. The function-safe design has proved the fault performance has ASIL D of ISO26262 standard fault tolerance levels. Therefore, the entire AI processor is fabricated via the 28-nm CMOS process as a prototype chip. Its peak computing performance is 40 TFLOPS at 1.2 GHz with the supply voltage of 1.1 V. The measured energy efficiency is 1.3 TOPS/W. A GPP for control with a function-safe design can have ISO26262 ASIL-D with the single-point fault-tolerance rate of 99.64%.

Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.289-293
    • /
    • 2007
  • The fault current limiting characteristics of the separated and the integrated three-phase flux-lock type superconducting fault current limiters (SFCLs) were analyzed. The three-phase flux-lock type SFCL consisted of three flux-lock reactors and three $high-T_c$ superconducting (HTSC) elements. In the integrated three-phase flux-lock type SFCL, three flux-lock reactors are connected on the same iron core. On the other hand, three flux-lock reactors of the separated three-phase flux-lock type SFCL are connected on three separated iron cores. The integrated three-phase flux-lock type SFCL showed the different fault current limiting characteristics from the separated three-phase flux-lock type SFCL that the fault phase could affect the sound phase, which resulted in quench of the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the separated and the integrated three-phase flux-lock type SFCLs according to the ground fault types were compared.

회귀분석을 이용한 경주·울산 지역에 분포하는 단층 핵의 전단강도 범위 설정 (Setting of the range for shear strength of fault cores in Gyeongju and Ulsan using regression analysis)

  • 윤현석;문성우;서용석
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.127-140
    • /
    • 2015
  • 단층은 굴착공사 중 발생하는 붕괴의 주요원인 중 하나이다. 하지만 단층대 내에서 주요 파괴면으로 작용하는 단층 핵은 파쇄암과 가우지가 불균질하게 분포하는 부분으로서 전단강도의 분포범위가 넓기 때문에 안정성 해석 시 경험적으로 결정되는 경우가 많다. 본 연구에서는 경주와 울산의 12개 지점에서 채취한 62개의 단층 핵 시료를 대상으로 직접전단시험과 입도 분석을 수행하였다. 실내시험으로 얻어진 결과를 이용하여 회귀 분석을 수행하여 수직응력별 입도에 따른 전단강도의 범위를 결정하였다. 자갈의 무게비는 전단강도와 비례하며, 실트 및 점토의 무게비는 반비례하는 것으로 나타났다. 결정계수는 대부분 약 0.7 이상으로 시료의 불균질성을 고려할 때 비교적 높게 나타났으며, 분석된 회귀모형의 95% 신뢰 구간을 설정하여 무게비에 따른 전단강도의 상한과 하한 범위를 결정하였다.