• 제목/요약/키워드: Fast current control

Search Result 426, Processing Time 0.029 seconds

A Current Control Algorithm for Torque Ripple Reduction of Four-Switch Three-Phase Brushless DC Motors (4스위치 3상 BLDC 전동기의 토크 리플 저감을 위한 전류제어 알고리즘)

  • Park S.H.;Kim T.S.;Lee B.K.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.472-476
    • /
    • 2003
  • In this paper, a new current control algorithm is proposed for four-switch three-phase brushless DC(BLU) motor drives, which are suitable for low cost applications. A current reference generation scheme is developed and Implemented to obtain high performance characteristics in the four-switch system, such as small torque ripple and fast dynamic speed/torque response. Moreover, the proposed scheme can successful1y eliminate the torque ripple during commutations, so that it can be expected that the four-switch system can be much more practically applied for the industrial application areas.

  • PDF

A Design of Battery Charger using Phase-Lock technique (Phase-Lock 기법을 이용한 Battery 충전기 설계)

  • Song, Eui-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.456-458
    • /
    • 1997
  • The phase-lock technique is applied to a three-phase semi-bridge type battery charger system. Using an inner fast dynamic loop, the phase-locked voltage control (PLVC) technique of three-phase semi-bridge converter is proposed to give a frequency synchronism and to reduce the subharmonics due to the unbalance of transformer or power line. To protect the power devices, the two stage soft-start, function with softly locking the phase and softly increasing the current is presented. As limiting the reference voltage of the inner voltage control loop, muti-lock phenomena are removed on the PLVC loop. A current limit function is also proposed to limit the current of battery and converter. The proposed controller is confirmed through experiment results.

  • PDF

Design and Stability Analysis of a Fuzzy Adaptive SMC System for Three-Phase UPS Inverter

  • Naheem, Khawar;Choi, Young-Sik;Mwasilu, Francis;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.704-711
    • /
    • 2014
  • This paper proposes a combined fuzzy adaptive sliding-mode voltage controller (FASVC) for a three-phase UPS inverter. The proposed FASVC encapsulates two control terms: a fuzzy adaptive compensation control term, which solves the problem of parameter uncertainties, and a sliding-mode feedback control term, which stabilizes the error dynamics of the system. To extract precise load current information, the proposed method uses a conventional load current observer instead of current sensors. In addition, the stability of the proposed control scheme is fully guaranteed by using the Lyapunov stability theory. It is shown that the proposed FASVC can attain excellent voltage regulation features such as a fast dynamic response, low total harmonic distortion (THD), and a small steady-state error under sudden load disturbances, nonlinear loads, and unbalanced loads in the existence of the parameter uncertainties. Finally, experimental results are obtained from a prototype 1 kVA three-phase UPS inverter system via a TMS320F28335 DSP. A comparison of these results with those obtained from a conventional sliding-mode controller (SMC) confirms the superior transient and steady-state performances of the proposed control technique.

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

Study on High-Efficiency Driving of a Piezo Device Using Voltage Inversion Circuit (전압 극성 전환을 통한 피에조 소자의 에너지 회수형 구동 기법 연구)

  • Park, Han-Bin;Park, Jin-Ho;Hong, Sun-Ki;Kang, Taesam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1843-1847
    • /
    • 2012
  • Piezo devices have large power density and simple structure. They can generate larger force than the conventional actuators. It has also wide bandwidth with fast response in a compact size. Thus the piezo devices are expected to be used widely in the future for small actuators with fast response time and large actuating force. However, the piezo actuators need high voltage with high driving current due to their large capacitive property. In this paper, we propose a simple method to drive piezo devices using voltage inversion circuit with coil inductance. Experiments with real circuit demonstrates that the proposed scheme can improve the energy efficiency very much.

A Low Jitter and Fast Locking Phase-Lock Loop with Adaptive Bandwidth Controller

  • Song Youn-Gui;Choi Young-Shig
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.1
    • /
    • pp.18-22
    • /
    • 2005
  • This paper presents the analog adaptive phase-locked loop (PLL) architecture with a new adaptive bandwidth controller to reduce locking time and minimize jitter in PLL output for wireless communication. It adaptively controls the loop bandwidth according to the locking status. When the phase error is large, the PLL increases the loop bandwidth and reduces locking time. When the phase error is small, the PLL decreases the loop bandwidth and minimizes output jitters. The adaptive bandwidth control is implemented by controlling charge pump current depending on the locking status. A 1.28-GHz CMOS phase-locked loop with adaptive bandwidth control is designed with 0.35 $mu$m CMOS technology. It is simulated by HSPICE and achieves the primary reference sidebands at the output of the VCO are approximately -80dBc.

A Single-Phase Active Power Filter Control with Load Current Estimation Method (부하전류 추정기법에 의한 단상능동전력필터 제어)

  • 곽상신;이무영;최연호;임성운;권우현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.335-342
    • /
    • 2000
  • A new control method for a single-phase active power filter, based on a load current estimation using a DC capacitor voltage of active power filter without sensing nonlinear load current, is proposed in this paper. Because the method proposed can remove the load current sensor in comparison with a conventional method sensing the load current and DC capacitor voltage together, it can make the active power filter easy installation, low cost, small size with no performance detriment. In addition, sample-hold technique and proportional control method is adopted to control the DC capacitor voltage and as no delay element such as LPF or PI control in the conventional method is used, the transient response is fast and good. Operation of a single-phase active power filter which consist of eight mode is explained according to utility voltage, compensation current and switch state, and compensation characteristics of active power filter using proposed method is verified by experiment.

  • PDF

DESIGN OF A LOAD FOLLOWING CONTROLLER FOR APR+ NUCLEAR PLANTS

  • Lee, Sim-Won;Kim, Jae-Hwan;Na, Man-Gyun;Kim, Dong-Su;Yu, Keuk-Jong;Kim, Han-Gon
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.369-378
    • /
    • 2012
  • A load-following operation in APR+ nuclear plants is necessary to reduce the need to adjust the boric acid concentration and to efficiently control the control rods for flexible operation. In particular, a disproportion in the axial flux distribution, which is normally caused by a load-following operation in a reactor core, causes xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. A model predictive control (MPC) method was used to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for APR+ nuclear plants. Some tracking controllers employ the current tracking command only. On the other hand, the MPC can achieve better tracking performance because it considers future commands in addition to the current tracking command. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at the current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the procedure to solve the optimization problem is then repeated. The support vector regression (SVR) model that is used widely for function approximation problems is used to predict the future outputs based on previous inputs and outputs. In addition, a genetic algorithm is employed to minimize the objective function of a MPC control algorithm with multiple constraints. The power level and ASI are controlled by regulating the control banks and part-strength control banks together with an automatic adjustment of the boric acid concentration. The 3-dimensional MASTER code, which models APR+ nuclear plants, is interfaced to the proposed controller to confirm the performance of the controlling reactor power level and ASI. Numerical simulations showed that the proposed controller exhibits very fast tracking responses.

Vector Control Implementation of PMSM Using dSPACE 1104 System (dSPACE 1104 시스템을 이용한 영구자석 동기전동기 벡터제어 구현)

  • Lee, Yong-Seok;Lee, Dong-Min;Ji, Jun-Keun;Cha, Gui-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1084-1085
    • /
    • 2007
  • This paper presents a vector control implementation for SPMSM(Surface-mounted Permanent Magnet Synchronous Motor) using dSPACE 1104 system and MATLAB/SIMULINK. SPMSM can be treated as a DC motor provided that currents of flux and torque component are controlled independently using vector control. Therefore various control algorithms for conventional DC motor control can be adopted to SPMSM. The system is designed to improve set-point tracking capability, fast response, and accuracy. In This paper, d-q equivalent modeling of PMSM is derived based on vector control theory. The PI controller is used for speed control and state feedback PI current control method is used for current control. For the implementation of high performance vector control system, dSPACE 1104 system is used. Simulations and experiments were carried out to examine validity of the proposed vector control implementation.

  • PDF

Role of Water Current in the CROM Operation for the Water Quality Improvement of Eutrophic Reservoir (부영양 저수지의 수질개선을 위한 CROM 운영 및 유속의 영향)

  • Lee, Ju-Hwan;Hwang, Soon-Jin;Kim, Baik-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.518-524
    • /
    • 2010
  • Continuous removal of organic matters (CROM) using freshwater bivalve Anodonta woodiana was operated to evaluate the effect of water current on the water quality improvement (clearance) of eutrophic lake. The CROM system comprised three treatment steps such as flow control, treatment and analysis, and operated at the two different currents ($24L\;h^{-1}$ and $48L\;h^{-1}$) with mussels at density of $312.5indiv.\;m^{-2}$ for 12 consecutive days. Water quality including suspended solids (SS) and chlorophyll-a (Chl-a) was daily measured at the same time. Results indicate that although both the system strongly decreased the concentration of SS and chl-a, a slow CROM system was more effective to diminish the SS contents than a fast CROM system; 82% and 66%, respectively (ANOVA, P<0.0001). Clearance rates, based on chl-a, were also significantly higher in a slow system than a fast system (ANOVA, P<0.0001), although the mussel mortality was conversely. In both systems, there showed a remarkable excretion of dissolved inorganic nutrients (i.e. $NH_3-N$ and $PO_4-P$), while a slow CROM system was higher than a fast system, significantly (ANOVA, P<0.0001). Therefore, it may suggest that a slow current CROM system is more suitable to maximize the efficacy of water quality improvement, but further study is needed to diminish the mortality of mussel and to reuse the nutrient released during the operation.