• 제목/요약/키워드: Fast current control

검색결과 426건 처리시간 0.025초

한국의 환경오염방지산업 (Environmental Pollution Control Industry in Korea)

  • 이달우
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.53-68
    • /
    • 1992
  • Since 1962, Korea has made a remarkable progress with continuous success of Five-Year Economic Development Plans. Over the last 30 years, Korea has achieved a fast growth in various industries including heavy industry and chemical industry with rapid urbanization at the same time. The fast industrialization and urbanization brought about huge amount of hazardous/toxic substances and wastes. The environmental pollution problems have now emerged from regional concerns to overall social issues accordingly. The situation has come to a point where pollution control and environment preservation have become one of the nation's major policies. Following the recent Earth Summit of UNCED Conference held in Riode Janeiro in June 1992, where the topic was environmentally sound and sustainable development, awareness upon the importance of environmental preservation has been heightened globally, The environmental issues will gradually influence the international society more and more, politically as well as economically, The environmental pollution control industry in Korea started in the early 70's with the development of the nation's industrialization, As the people's awareness on pollution increases and environmental laws and enforcing regulations were established, demand for pollution control began to increase. The environmental pollution control business came to be recognized as an independent industry in the mid'70's. It should be evaluated properly that over the last 30 years, the Korean pollution control industry has supplied locally manufactured pollution control facilities to the increasing local demand. Concerning the quality and customer satisfaction, however, there are still many aspects which need to be improved compared with those of advanced countries. Although the start of the pollution control industry in Korea is just 10 to 15 years behind the advanced countries such as Japan and European countries, current gap in the environmental technology is rather considerable. And, studies should be made to find out the reasons for the current technology gap, and therefore, to implement solutions to improve the technology and competitiveness of the environmental pollution control industry in Korea.

  • PDF

A High-Power Step-up Converter with High Efficiency and Fast Control-to-Output Dynamics

  • Kang, Jeong-il;Roh, Chung-Wook;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.78-87
    • /
    • 2001
  • A new high-power step-up based on the two-module parallel-input (PISO) modular dual inductor-fed push-pull converter is proposed. The proposed converter is operated at a constant duty cycle and employs and auxiliary circuit to control the output voltage with a phase-shift between two modules. It shows a high efficiency due to the greatly reduced switch turn-off stress. It also shows a high and linear voltage conversion ratio, low current stress in the output capacitor, and fast control-to-output dynamics. The operation principles and the mathematical models of the proposed converter are presented. Features of the proposed converter are discussed in comparison with the two-module PISO modular dual inductor-fed push-pull converter. Also, experimental results from a 50kHz, 800W, 350 Vdc prototype with an input voltage range of 20-32 Vdc are provided to confirm the validity of the proposed converter. The new converter compares favorably with the conventional counterpart, and is considered well siuted to high-power step-up applications.

  • PDF

단상 AC/AC 컨버터에 관한 연구 (A study on the single phase AC/AC converter)

  • 배상준;정타관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1931-1933
    • /
    • 1998
  • In this paper, single-phase PWM AC to AC converter that operates with unit power factor and sinusoidal input line currents is presented. The output voltage of this converter is able to be obtain step up voltage as well as step down voltage. because the converter applies to operating method of buck-boost converter. The control of this converter is performed with PI control method. By using this control method low lipples in the output current and the voltage as well as fast dynamic response are achieved.

  • PDF

A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2012
  • The current paper presents a novel control strategy of a three-phase, four-wire Unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage Source Inverter (VSI), and the series APF is realized using a three-phase, three-leg VSI. To extract the fundamental source voltages as reference signals for series APF, a zero-crossing detector and sample-and-hold circuits are used. For the control of shunt APF, a simple scheme based on the real component of fundamental load current (I $Cos{\Phi}$) with reduced numbers of current sensors is applied. The performance of the applied control algorithm is evaluated in terms of power-factor correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. The reference signals and sensed signals are used in a hysteresis controller to generate switching signals for shunt and series APFs. In this proposed UPQC control scheme, the current/voltage control is applied to the fundamental supply currents/voltages instead of fast-changing APF currents/voltages, thus reducing the computational delay and the required sensors. MATLAB/Simulink-based simulations that support the functionality of the UPQC are obtained.

동적변화에 강인한 연료전지 발전시스템의 저주파 리플전류 제거 알고리즘 개발 (Development of Robust Algorithm to Eliminate Low Frequency Current Ripples in Fuel Cell Generation System)

  • 김종수;강현수;최규영;이병국
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1720-1727
    • /
    • 2009
  • This paper presents that generation and propagation mechanism of low frequency current ripples generated by a rectification effect of an inverter in fuel cell generation system is analyzed. The ripple reduction methode using hardware components such as capacitors and inductors is examined to reduce low frequency current ripples. A new fast and robust low frequency current ripple elimination algorithm is then proposed to incorporate a single loop current controller, which directly controls fuel cell current, without any extra hardware. The proposed algorithm can completely eliminate this current ripple as well as an overshoot or undershoot is significantly reduced. And the de link voltage and output current are well regulated by inverter controller. The validity of proposed algorithm is verified both computer simulation using PSIM 6.0 and experiment with a 1kW laboratory prototype.

Fast Diagnosis Method for Submodule Failures in MMCs Based on Improved Incremental Predictive Model of Arm Current

  • Xu, Kunshan;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1608-1617
    • /
    • 2018
  • The rapid and correct isolation of faulty submodules (SMs) is of great importance for improving the reliability of modular multilevel converters (MMCs). Therefore, a fast diagnosis method containing fault detection and fault location determination was presented in this paper. An improved incremental predictive model of arm current was proposed to detect failures, and the multi-step prediction method was used to eliminate the negative impact of disturbances. Moreover, a control method was proposed to strengthen the fault characteristics to rapidly locate faulty arms and faulty SMs by detecting the variation rate of the SM capacitor voltage. The proposed method can rapidly and easily locate faulty SMs under different load conditions without the need for additional sensors. The experimental results have validated the effectiveness of the proposed method by using a single-phase MMC with four SMs per arm.

Understanding of RF Impedance Matching System Using VI-Probe

  • Lee, Ji Ha;Park, Hyun Keun;Lee, Jungsoo;Hong, Snag Jeen
    • 반도체디스플레이기술학회지
    • /
    • 제19권3호
    • /
    • pp.43-48
    • /
    • 2020
  • The demand for stable plasma has been on the rise because of the increased delivery power amount in the chamber for improving productivity, and fast and accurate plasma impedance matching become a crucial performance measure for radio frequency (RF) power system in semiconductor manufacturing equipment. In this paper, the overall impedance matching was understood, and voltage and current values were extracted with voltage - current (VI) probe to measure plasma impedance in real-time. Actual matching data were analyzed to derive calibration coefficient for V and I measurements to understand the characteristics of VI probe, and we demonstrated the tendency of RF impedance matching according to changes in load impedance. This preliminary empirical research can contribute to fast RF matching as well as advanced equipment control for the next level of detailed investigation on embedded system based-RF matching controller.

A Fast-Transient Repetitive Control Strategy for Programmable Harmonic Current Source

  • Lei, Wanjun;Nie, Cheng;Chen, Mingfeng;Wang, Huajia;Wang, Yue
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.172-180
    • /
    • 2017
  • The repetitive control (RC) strategy is widely used in AC power systems because of its high performance in tracking period signal and suppressing steady-state error. However, the dynamic response of RC is determined by the fundamental period delay $T_0$ existing in the internal model. In the current study, a ($nk{\pm}i$)-order harmonic RC structure is proposed to improve dynamic performance. The proposed structure has less data memory and can improve the tracking speed by n/2 times. $T_0$ proves the effectiveness of the ($nk{\pm}i$)-order RC strategy. The simulation and experiments of ($6k{\pm}1$)-order and ($4k{\pm}1$)-order RC strategy used in the voltage source inverter is conducted in this study to control the harmonic current source, which shows the validity and advantages of the proposed structure.

댐 방류조건에 따른 저수지 유속과 수온 영향 (The Effect of Current and Temperature of a Reservoir by the Simulation of Dam Outflow)

  • 유순주;하성룡;정동일
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1060-1067
    • /
    • 2006
  • Water quality in the Daecheong reservoir has been deteriorated by algal bloom due to nutrient supply from the upstream of the Daecheong reservoir after heavy rainfall. Algal bloom is propagated from eutrophicated tributary into the main body of the reservoir according to the hydrological conditions. This study is aimed to estimate the water current and temperature effect by the simulation of dam spill flow control using water quality model, CE-QUAL-W2 in 2003. Water current was resulted in nutrient transport from upstream of main reservoir and nutrients were delivered up to downstream by fast water velocity. Algal blooms occurred in stagnate zone of reservoir downstream as the current of downstream was retarded according to dam outflow control. Consequently water balance in stagnate zone triggered a rise of water temperature in summer. It affected algal bloom in the embayment of the reservoir. The simulation result by outflow control scenarios showed that spill flow augmentation induced in water body instability of stagnate zone so that water temperature declined. It could be suggested that outflow control minimize algal bloom in the downstream in the flooding season as long as water elevation level is maintained properly.

입력 전류 파형과 역률 개선 제어기법에 의한 3상 PWM 컨버터 해석 (Analysis of a Three Phase PWM AC/DC Converter With Input Current Waveform and Power Factor Correction)

  • 이수흠;배영호;최종수;백종현
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.93-102
    • /
    • 1998
  • 본 논문에서는 자기 소호 능력을 가지고 있는 전력용 반도체 소자로 구성된 3상 PWM Boost 컨버터를 이용하여 기존의 정류기에서 나타나는 문제점들을 해결하고, 입력 전류와 역률을 개선하기 위한 전류제어 기법을 제시한다. 이 컨버터의 전류제어는 부하에 관계없이 항상 일정한 스위칭 주파수로 동작되는 예측 전류제어 기법을 적용하고 있으며, 선전류는 한 샘플링 시간 구간내에서 기준 전류를 추종하게 된다. 이 제어 기법을 사용하므로서 입력 전류의 파형이 거의 정현파에 가까워져 역률도 거의 1로되고, 작은 DC링크 캐패시터를 적용함에도 불구하고 출력 전류와 전압의 리플이 적으며, 다이나믹 응답 특성도 매우 양호하게 나타난다.

  • PDF