References
- Y. Han, L. Xu, M. M. Khan, C. Chen, G. Yao, and L.-D. Zhou, "Robust deadbeat control scheme for a hybrid APF with resetting filter and ADALINE-based harmonic estimation algorithm," IEEE Trans. Ind. Electron., Vol. 58, No. 9, pp. 3893-3904, Sep. 2011. https://doi.org/10.1109/TIE.2010.2093475
- M. Angulo, D. A. Ruiz-Caballero, J. Lago, M. L. Heldwein, and S. A. Mussa, "Active power filter control strategy with implicit closedloopcurrent control and resonant controller," IEEE Trans. Ind. Electron.,Vol. 60, No. 7, pp. 2721-2730, Jul. 2013. https://doi.org/10.1109/TIE.2012.2196898
- L. R. Limongi, R. Bojoi, G. Griva, and A. Tenconi, "Digital current control schemes," IEEE Ind. Electron. Mag., Vol. 3, No. 1, pp. 20-31, Mar. 2009. https://doi.org/10.1109/MIE.2009.931894
- P. Mattavelli and F. P. Marafao, "Repetitive-based control for selective harmonic compensation in active power filters," IEEE Trans. Ind. Electron., Vol. 51, No. 5, pp. 1018-1024, Oct. 2004. https://doi.org/10.1109/TIE.2004.834961
- B. Francis and W. Wonham, "The internal model principle of control theory," Automatica, Vol. 12, No. 5, pp. 457-465, Sep. 1976. https://doi.org/10.1016/0005-1098(76)90006-6
- G. Escobar, A. Valdez, J. Leyva-Ramos, and P. Mattavelli, "Repetitive based controller for a UPS inverter to compensate unbalance and harmonic distortion," IEEE Trans. Ind. Electron., Vol. 54, No.1, pp. 504-510, Feb. 2007. https://doi.org/10.1109/TIE.2006.888803
- F. Botteron and H. Pinheiro, "A three-phase UPS that complies with the standard IEC 62040-3," IEEE Trans. Ind. Electron., Vol. 54, No. 4,pp. 2120-2136, Aug. 2007. https://doi.org/10.1109/TIE.2007.894782
- K. Zhou, D. Wang, B. Zhang, Y. Wang, J. A. Ferreira, and S. W. H. deHaan, "Dual-mode structure digital repetitive control," Automatica, Vol. 43, No. 3, pp. 546-554, Mar. 2007. https://doi.org/10.1016/j.automatica.2006.09.018
- K. Zhou, D.Wang, B. Zhang, and Y.Wang, "Plug-in dual-mode-structure repetitive controller for CVCF PWM inverters," IEEE Trans. Ind. Electron., Vol. 56, No. 3, pp. 784-791, Mar. 2009. https://doi.org/10.1109/TIE.2008.2005149
- S. Jiang, D. Cao, Y. Li, J. Liu, and F. Z. Peng, "Low THD, fast-transient, and cost-effective synchronous-frame repetitive controller forthree-phase UPS inverters," IEEE Trans. Power Electron., Vol. 27, No. 6, pp. 2994-3005, Jun. 2012 https://doi.org/10.1109/TPEL.2011.2178266
- C. Cosner, G. Anwar, and M. Tomizuka, "Plug in repetitive control for industrial robotic manipulators," in Proc. IEEE Int. Conf. Robot. Autom., pp. 1970-1975, May 1990.
- W. Zhao and G. Chen, "Comparison of active and passive damping methods for application in high power active power filter with LCL filter," Intemational Conference on Sustainable Power Generation and Supply. Nanjing: IEEE, pp. 1-6, Dec. 2009.
- J. Dannehl, F. W. Fuchs, S. Hansen S, and P. B. Thogersen, "Investigation of active damping approaches for PI-based current control of grid-connected pulse width modulation converters with LCL filters," IEEE Trans. Ind. Appl., Vol. 46, No. 4, pp. 1509-1517, Jul. 2010. https://doi.org/10.1109/TIA.2010.2049974
-
W. Lu, K. Zhou, D. Wang, and M. Cheng, "A generic digital nk
${\pm}$ m-order harmonic repetitive control scheme for PWM converters," IEEE Trans. Ind. Electron., Vol. 61, No. 3, pp. 1516-1526, Mar, 2014. https://doi.org/10.1109/TIE.2013.2258295 - W. Lu, K. Zhou, and D.Wang, "General parallel structure digital repetitive control," Int. J. Control, Vol. 86, No. 1, pp. 70-83, Jan. 2013. https://doi.org/10.1080/00207179.2012.718798
Cited by
- A Single-Loop Repetitive Voltage Controller with an Active Damping Control Technique vol.10, pp.5, 2017, https://doi.org/10.3390/en10050673
- CRC and NHPWM method for test bench based on cascaded converter pp.1755-4543, 2019, https://doi.org/10.1049/iet-pel.2018.5477