• Title/Summary/Keyword: Fan-out

Search Result 536, Processing Time 0.03 seconds

Analysis of Performance of Cross-Flow Fan with Various Rear Guiders (리어가이더 형상변화에 따른 횡류홴 성능해석)

  • Kim, Dong-Won;Lee, Jun-Hwan;Park, Seong-Gwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

Numerical Investigation on Aerodynamic Performance of a Centrifugal Fan with Splitter Blades

  • Kim, Jin-Hyuk;Cha, Kyung-Hun;Kim, Kwang-Yong;Jang, Choon-Man
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.4
    • /
    • pp.168-173
    • /
    • 2012
  • This paper presents a numerical investigation on the aerodynamic performance according to the application of splitter blades in an impeller of a centrifugal fan used for a refuse collection system. Numerical analysis of a centrifugal fan was carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model. A validation of numerical results was conducted by comparison with experimental data for the pressure and efficiency. From analyses of the internal flow field of the reference fan, the losses by the reverse-flows were observed in the region of the blade passage. In order to reduce these losses and enhance fan performance, two splitter blades were applied evenly between the main blades, and centrifugal impellers having the different numbers of the main blades were tested with their application. Throughout the numerical analyses of the centrifugal fan with splitter blades, it was found that the reverse-flow regions in the blade passage can be reduced by controlling the main blade numbers with splitter blades. The application of splitter blades in a centrifugal fan leads to significant improvement in the overall fan performance.

An Experimental Study on Selection Pitch Angle on backward flow of an Axial Fan with Adjustable Pitch Angle Blades (피치각 조정형 송풍-역풍 겸용 축류팬에서 배연용 피치각 선정을 위한 실험적 연구)

  • Chang, Taek-Soon;Hur, Jin-Huek;Moon, Seung-Jae;Lee, Jae-Heon;You, Ho-Sun;Im, Yun-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.145-150
    • /
    • 2008
  • In this study, the experimental study has carried out to select pitch angle on the backward flow in an axial fan that has adjustable pitch blades. With the change of pitch angle of axial fan with adjustable blade, air flow rate, pressure and air flow direction can be changed. Because of this merit, adjustable axial fan can be used in the backward flow. For the selection of the backward flow pitch angle, fan performance test method is selected by KS B 6311. Dynamic pressure, static pressure, electric current and voltage are measured in each pitch angles of axial fan that are $36^{\circ}C$, $-16^{\circ}C$, $-21^{\circ}C$, $-26^{\circ}C$, $-31^{\circ}C$ and $-36^{\circ}C$. In the result of test, fan performance curves at several pitch angle has been investigated. Finally, pitch angle of $-26^{\circ}C$ has been selected to get largest flow rate at backward flow situation.

  • PDF

Effect of Inlet Geometry on Fan Performance and Inlet Flow Fields in a Semi-opened Axial Fan

  • Liu, Pin;Shiomi, Norimasa;Kinoue, Yoichi;Setoguchi, Toshiaki;Jin, Ying-Zi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.60-67
    • /
    • 2014
  • In order to clarify the effect of inlet bellmouth size of semi-opened type axial fan on its performance and flow fields around rotor, fan test and flow field measurements using hotwire anemometer were carried out for 6 kinds of bellmouth size. As results of fan test, the shaft power curve hardly changed, even if the bellmouth size changed. On the other hand, the pressure-rise near best efficiency point became small with the bellmouth size decreasing. Therefore, the value of maximum efficiency became small as the bellmouth size decreased. As results of flow field measurements at fan inlet, the main flow region with large meridional velocity existed near blade tip when the bellmouth size was large. As bellmouth size became smaller, the meridional velocity at fan inlet became smaller and the one at outside of blade tip became larger. As results of flow field measurements at fan outlet, the main flow region existed near rotor hub side.

Numerical analyses on the Aerodynamic Characteristics of a Counter-rotating Axial Flow Fan (고성능 엇회전식 축류팬의 공력특성에 대한 전산해석)

  • Cho, Leesang;Cho, Jinsoo
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.1
    • /
    • pp.37-40
    • /
    • 2015
  • Numerical analyses on the aerodynamic characteristics of a counter rotating axial flow fan is carried out using the frequency domain panel method. Front rotor and rear rotor blades of a counter rotating axial fan are designed by using the simplified meridional flow analysis method with the radial equilibrium equation and the free vortex design condition, according to design requirements. Performance characteristics of a counter rotating axial flow fan are estimated for the variation of design parameters such as the hub to tip ratio, the taper ratio and the solidity. Pressure losses were higher at leading edge and hub region of rotor blades. Characteristic curve of the counter rotating fan was overpredicted without consideration of viscous effect.

Development of Electrical and Oil Heater for Energy Saving (에너지 절감형 전기 유류 겸용 온풍기 개발)

  • Chung, Sung-Won;Kim, Dong-Keon;Gong, Sang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

Analysis of Flow Characteristics on the Axial Flow Fan with Centrifugal Blade (원심형 날개를 부착한 축류홴의 유동특성 해석)

  • Choi Jung-Geun;Lee Seok-Jong;Lee Myoeng-Ho;Sung Jae-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.589-596
    • /
    • 2006
  • This study aims to propose a new model axial flow fan which attachs centrifugal blades, and to investigate the effect of centrifugal blades on the performance improvement of new model axial flow fan. A numerical simulation has been conducted using STAR-CD commercial code to solve the three dimensional incompressible Navier-Stokes equation for high Reynolds number $k-{\epsilon}$ turbulent model. Numerical simulation is carried out to investigate the detail phenomenon in the flow field and performance characteristics of new model and normal model fan. Calculation results are compared with normal model's results to investigate which centrifugal blades effect on velocity profile and pressure distribution at various flow field positions. and calculation results show that new model fan can improve the performance of total pressure.

Development of the Front End Cooling Fan of a Car (자동차 프런트 엔드 쿨링팬 개발)

  • Oh, Keon-Je;Cho, Won-Bong;Bae, Chun-Keun;Lee, Su-Hwa;Lee, Seung-Bae;Ju, Phil-Ho;Kim, Jong-Cheol
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.384-390
    • /
    • 2005
  • A automobile front-end cooling fan are designed and tested in the present study. The design technique is developed using the one-dimensional inviscid flow through the fan blade, the empirical equations, and the performance prediction models. Numerical calculations of the three-dimensional turbulent flow around the designed cooling fan are carried out. Flow characteristics and pressure distributions on the pressure and suction side of the fan are investigated. Performance test results of the total pressure and flow rate are presented.

  • PDF

A Study on Performance of Cooling Fan for Auto Transmission Oil Cooler in the Large-Size Diesel Engine (대형 디젤엔진 자동변속기 오일쿨러 냉각팬 성능에 관한 연구)

  • Yi, Chung-Seob;Suh, Jeong-Se;Song, Chul-Ki;Yun, Ji-Hun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.71-76
    • /
    • 2010
  • This study has investigated numerically and experimentally the flow characteristic of air-cooling fan for transmission oil cooler in the large-size diesel engine. Impellers of cooler were composed of eight normal-scale and eight small-scale blades in the zig-zag pattern. In order to increase the discharge pressure of cooling fan, turbo type of fan blade is proposed in the impeller for transmission oil cooler. The fluidic performance of cooling fan has been estimated numerically by using the commercial code and experimentally carried out with reference on AMCA Standard 210-99. As a result, it is confirmed that the numerical result for performance curve is in good agreement with experimental data.

A Study on the Fault Detection in combinational Logic Networks with Fan-out (출력분기가 있는 조합논리회로의 고장검출에 과한 연구)

  • 임재탁;이근영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.4
    • /
    • pp.12-18
    • /
    • 1974
  • In this paper, we are concerned with the problem of generating fault-detection experiment for combinational logic networks with fan-out. We establish the lower limit on the necessary number of fault-section tests and show how such experiments can be obtained by considering inversion parity from the output to the point whore fan-out exilts on the networks. Boolean difference is used advantageously.

  • PDF