Effect of Inlet Geometry on Fan Performance and Inlet Flow Fields in a Semi-opened Axial Fan

  • Liu, Pin (Department of Mechanical Engineering, Saga University) ;
  • Shiomi, Norimasa (Department of Mechanical Engineering, Saga University) ;
  • Kinoue, Yoichi (Department of Mechanical Engineering, Saga University) ;
  • Setoguchi, Toshiaki (Department of Mechanical Engineering, Saga University) ;
  • Jin, Ying-Zi (Institute of Mechatronics, Zhejiang Sci-Tech University)
  • Received : 2013.03.12
  • Accepted : 2014.04.15
  • Published : 2014.06.30

Abstract

In order to clarify the effect of inlet bellmouth size of semi-opened type axial fan on its performance and flow fields around rotor, fan test and flow field measurements using hotwire anemometer were carried out for 6 kinds of bellmouth size. As results of fan test, the shaft power curve hardly changed, even if the bellmouth size changed. On the other hand, the pressure-rise near best efficiency point became small with the bellmouth size decreasing. Therefore, the value of maximum efficiency became small as the bellmouth size decreased. As results of flow field measurements at fan inlet, the main flow region with large meridional velocity existed near blade tip when the bellmouth size was large. As bellmouth size became smaller, the meridional velocity at fan inlet became smaller and the one at outside of blade tip became larger. As results of flow field measurements at fan outlet, the main flow region existed near rotor hub side.

Keywords

References

  1. T. Shigemitsu, J. Fukutomi and T. Agawa, 2013, "Internal Flow Condition of High Power Contra-Rotating Small-Sized Axial Fan," International Journal of Fluid Machinery and Systems, Vol. 6, No. 1, pp. 25-32. https://doi.org/10.5293/IJFMS.2013.6.1.025
  2. N. Shiomi, Y. Kinoue, T. Setoguchi and K. Kaneko, 2011, "Vortex Features in a Half-ducted Axial Fan with Large Bellmouth (Effect of Tip Clearance)," International Journal of Fluid Machinery and Systems, Vol. 4, No. 3, pp. 307-316. https://doi.org/10.5293/IJFMS.2011.4.3.307
  3. L. Zhu, Y.-Z. Jin, Y. Li, Y. Jin, Y. Wang and L. Zhang, 2013, "Numerical and Experimental Study on Aerodynamic Performance of Small Axial Flow Fan with Splitter Blades," Journal of Thermal Science, Vol. 22, No. 4, pp. 333-339. https://doi.org/10.1007/s11630-013-0632-z
  4. S. Sasaki, I. Torise, H. Hayashi, 2012, "An Experimental and Numerical Study on Wake Vortex Noise of a Low Speed Propeller Fan," Open Journal of Fluid Dynamics, Vol. 2012, pp. 290-296.
  5. T. Shigemitsu, J. Fukutomi, and Y. Okabe, 2010, "Performance and Flow Condition of Small-Sized Axial Fan and Adoption of Contra-Rotating Rotors," Journal of Thermal Science, Vol. 19, No. 1, pp. 1-6. https://doi.org/10.1007/s11630-010-0001-0
  6. N. Shiomi, Y. Kinoue, Y.-Z. Jin, T. Setoguchi and K. Kaneko, 2009, "Flow Fields with Vortex in a Small Semi-open Axial Fan," Journal of Thermal Science, Vol. 18, No. 4, pp. 294-300. https://doi.org/10.1007/s11630-009-0294-z
  7. M. Arai, T. Ishima, T. Obokata, 2003, "PIV Measurement and Numerical Prediction of Flow around a Fan : Effects of Bellmouth Shape and Position," Visualization, Suppl. 23(1), pp. 203-206. (in Japanese)
  8. Pin Liu, Norimasa Shiomi, Yoichi Kinoue, Ying-zi Jin, Toshiaki Setoguchi, 2012, "Effect of Inlet Geometry on Fan Performance and Flow Field in a Half-Ducted Propeller Fan," International Journal of Rotating Machinery, Vol. 2012, Article ID. 463585.

Cited by

  1. Performance Evaluation of a Variable Frequency Heat Pump Air Conditioning System for Electric Bus vol.8, pp.1, 2015, https://doi.org/10.5293/IJFMS.2015.8.1.013
  2. PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan vol.9, pp.2, 2016, https://doi.org/10.5293/IJFMS.2016.9.2.175
  3. Performance and Internal Flow of Contra-Rotating Small-Sized Cooling Fan vol.08, pp.02, 2018, https://doi.org/10.4236/ojfd.2018.82013