Development of Electrical and Oil Heater for Energy Saving

에너지 절감형 전기 유류 겸용 온풍기 개발

  • 정성원 (부산대학교 바이오산업기계공학과) ;
  • 김동건 (부산대학교 기계기술연구원) ;
  • 공상호 ((주)프로다이나믹스산업)
  • Received : 2011.01.05
  • Accepted : 2011.10.06
  • Published : 2011.10.31

Abstract

This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

Keywords

References

  1. 김진봉, 구대현, "에너지 절약형 전기 온풍기 개발", 대한전기학회 하계학술대회 논문집, pp. 21-23, 1994.
  2. 송교섭, "난방기 열이용 효율 향상 방안", 한국생물환경조절학회 시설원예연구, Vol. 10, No. 1, pp. 19-37, 1997.
  3. 조성환, 태춘섭, 최진호, 김경호, 권오갑, 유홍근, "그린하우스용 온수온풍겸용 난방기의 성능특성", 공기조화냉동공학회, 하계학술발표회 논문집, pp. 1320-1324, 2000.
  4. "ANSYS WORKBENCH USER'S MANUAL", ANSYS Inc., 2007.
  5. "ANSYS CFX Ver. 11 USER'S MANUAL", ANSYS Inc., 2007.