• Title/Summary/Keyword: Fan-out

Search Result 535, Processing Time 0.028 seconds

Comparison of Quantitative Interfacial Adhesion Energy Measurement Method between Copper RDL and WPR Dielectric Interface for FOWLP Applications (FOWLP 적용을 위한 Cu 재배선과 WPR 절연층 계면의 정량적 계면접착에너지 측정방법 비교 평가)

  • Kim, Gahui;Lee, Jina;Park, Se-hoon;Kang, Sumin;Kim, Taek-Soo;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • The quantitative interfacial adhesion energy measurement method of copper redistribution layer and WPR dielectric interface were investigated using $90^{\circ}$ peel test, 4-point bending test, double cantilever beam (DCB) measurement for FOWLP Applications. Measured interfacial adhesion energy values of all three methods were higher than $5J/m^2$, which is considered as a minimum criterion for reliable Cu/low-k integration with CMP processes without delamination. Measured energy values increase with increasing phase angle, that is, in order of DCB, 4-point bending test, and $90^{\circ}$ peel test due to increasing roughness-related shielding and plastic energy dissipation effects, which match well interfacial fracture mechanics theory. Considering adhesion specimen preparation process, phase angle, measurement accuracy and bonding energy levels, both DCB and 4-point bending test methods are recommended for quantitative adhesion energy measurement of RDL interface depending on the real application situations.

Analysis of Grover Attack Cost and Post-Quantum Security Strength Evaluation for Lightweight Cipher SPARKLE SCHWAEMM (경량암호 SPARKLE SCHWAEMM에 대한 Grover 공격 비용 분석 및 양자 후 보안 강도 평가)

  • Yang, Yu Jin;Jang, Kyung Bae;Kim, Hyun Ji;Song, Gyung Ju;Lim, Se Jin;Seo, Hwa Jeong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.12
    • /
    • pp.453-460
    • /
    • 2022
  • As high-performance quantum computers are expected to be developed, studies are being actively conducted to build a post-quantum security system that is safe from potential quantum computer attacks. When the Grover's algorithm, a representative quantum algorithm, is used to search for a secret key in a symmetric key cryptography, there may be a safety problem in that the security strength of the cipher is reduced to the square root. NIST presents the post-quantum security strength estimated based on the cost of the Grover's algorithm required for an attack of the cryptographic algorithm as a post-quantum security requirement for symmetric key cryptography. The estimated cost of Grover's algorithm for the attack of symmetric key cryptography is determined by the quantum circuit complexity of the corresponding encryption algorithm. In this paper, the quantum circuit of the SCHWAEMM algorithm, AEAD family of SPARKLE, which was a finalist in NIST's lightweight cryptography competition, is efficiently implemented, and the quantum cost to apply the Grover's algorithm is analyzed. At this time, the cost according to the CDKM ripple-carry adder and the unbounded Fan-Out adder is compared together. Finally, we evaluate the post-quantum security strength of the lightweight cryptography SPARKLE SCHWAEMM algorithm based on the analyzed cost and NIST's post-quantum security requirements. A quantum programming tool, ProjectQ, is used to implement the quantum circuit and analyze its cost.

Effects of Dielectric Curing Temperature and T/H Treatment on the Interfacial Adhesion Energies of Ti/PBO for Cu RDL Applications of FOWLP (FOWLP Cu 재배선 적용을 위한 절연층 경화 온도 및 고온/고습 처리가 Ti/PBO 계면접착에너지에 미치는 영향)

  • Kirak Son;Gahui Kim;Young-Bae Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.2
    • /
    • pp.52-59
    • /
    • 2023
  • The effects of dielectric curing temperature and temperature/humidity treatment conditions on the interfacial adhesion energies between Ti diffusion barrier/polybenzoxazole (PBO) dielectric layers were systematically investigated for Cu redistribution layer applications of fan-out wafer level package. The initial interfacial adhesion energies were 16.63, 25.95, 16.58 J/m2 for PBO curing temperatures at 175, 200, and 225 ℃, respectively. X-ray photoelectron spectroscopy analysis showed that there exists a good correlation between the interfacial adhesion energy and the C-O peak area fractions at PBO delaminated surfaces. And the interfacial adhesion energies of samples cured at 200 ℃ decreased to 3.99 J/m2 after 500 h at 85 ℃/85 % relative humidity, possibly due to the weak boundary layer formation inside PBO near Ti/PBO interface.

Presumption on the Failures, the Causes and the Reliability of the Mist and Dust Blower (미스트기 부품의 고장실태조사에 의한 신뢰성의 예측)

  • 금동혁;최재갑
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3702-3711
    • /
    • 1975
  • This study was originated to investigate the imparired parts of the mist and dust blowers and intended to analyze the causes of their failures by the use of the Weibull probability paper. By the use of the paper, the parts which were needed to change the design, the force of the urgency, the mean time between failures of the parts and the basic causes of the troubles could be predicted. The survey showed that the following parts got out of order: (A) flexible rubber hose, (B) blowing fan, (C) lead valve, (D) piston ring. (E) crank main bearing, (F) coil in magneto and (G) needle valve in carburettor. The analysis of the survey indicated that the parts G, C, E and D were belonged to "wear-out failure", and that the mean time between failures became shorter in order as indicated above. To insure longer lives of those parts, it would be necessary to change the design and the material and to upgrade operators mechanical technique of the mist and dust blower. The failure of the parts A, B and F was classified as "randomfailure", and they did not seem to be the "wear-out" at that time. The parts B and F was evaluated as "initial failure". Quality controls and operating tests by the producer. and the operational training for users should be strengthened so as to eliminate these failures. Were the failures only in the parts A, C, D, E, F and G, it could be said that the "reliability" of the mist and dust blower would fall to 10 percent in the second year, and 50 percent of the mist and dust blowers would fail in all parts A, C, D, E, F and G before the blower would have control insect and disease in 58.2 hectares. The use of the Weibull probability paper for analyzing failures of the mist and dust blowers was effective in that it analyzed failure in the relationship between strength of the parts and users actual circumstanoes.

  • PDF

The survival rate of fish discarded from trawler (트롤 어선에서 어획후 투기된 어류의 생존율)

  • 안희춘;양용수;박창두;조삼광;박해훈;정의철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.2
    • /
    • pp.87-91
    • /
    • 2003
  • Experimental fishing was carried out to investigate the survival rate of fishes discarded after hauling from the trawl and to develop the fishing gear and method for fisheries management which can improve the survival rate of young fishes escaped from the trawl codend in offshore korean southern sea and off Cheju Island of Korea. The young fishes were bred in fish cage on the board to measure the sustainable survival time for fishes escaped from grid panel and codend. The obtained results are summarized as follows' 1. Japanese flying squid(Todarodes pacjficus), mitra squid(Loligo chinesis), hair-tail( Trichiurus lepturus), john dory(Zeus japonicus), spanish mackerel(Scomberomorus niphonius), redlip croaker (Pseudosciaena polyactis) and blackthroat seaperch(Doederliinia berycoides) were dead instantly after hauling. 2. Survival rate of tiger shark(Galeocerdo cuvier), conger eel (Conger myriaster), red skate (Dasyatis akajei), black scraper(Navodon modestus) and japanese fan lobster(Ibacus ciliatus) might be high after discarding because they survived for long hours in fish cage. 3. Blotched eelpout(Zoarces gili) escaped from the escapement device(grid) was dead within 6 hours in the water tank installed on the board but 97% of tiger shark and 72% of conger eel survived over 72 hours. 4. Red skate escaped from trawl codend was dead within 60 hours in the water tank installed on the board but sustainable survival time of 25% of octopus(Paroctopus dofleini) and 100% of black scraper was over 72 hours. 5. Compared with the survival rate of rosefish(Helicolenus higendorfi) escaped from the escapement device(grid) and trawl codend, all of the rosefish escaped from the grid was dead within 7.2 hours but 8.3% of the rosefish escaped from the codend survived over 72 hours. 6. In comparison with the survival rate of japanese fan lobster survived over 72 hours, survival rate of japanese fan lobster escaped the codend was much higher as 75% than 33% of japanese fan lobster escaped from the grid.

Compressive behavior of concrete under high strain rates after freeze-thaw cycles

  • Chen, Xudong;Chen, Chen;Liu, Zhiheng;Lu, Jun;Fan, Xiangqian
    • Computers and Concrete
    • /
    • v.21 no.2
    • /
    • pp.209-217
    • /
    • 2018
  • The dynamic compressive behavior of concrete after freezing and thawing tests are investigated by using the split Hopkinson pressure bar (SHPB) technique. The stress-strain curves of concrete under dynamic loading are measured and analyzed. The setting numbers of freeze-thaw cycles are 0, 25, 50, and 75 cycles. Test results show that the dynamic strength decreases and peak strain increases with the increasing of freeze-thaw cycles. Based on the Weibull distribution model, statistical damage constitutive model for dynamic stress-strain response of concrete after freeze-thaw cycles was proposed. At last, the fragmentation test of concrete subjected to dynamic loading and freeze-thaw cycles is carried out using sieving statistics. The distributions of the fragment sizes are analyzed based on fractal theory. The fractal dimensions of concrete increase with the increasing of both freeze-thaw cycle and strain rate. The relations among the fractal dimension, strain rates and freeze-thawing cycles are developed.

A study on the mixed-convection heat transfer characteristics of a simulated module on the bottom in the inclined channel (경사진 채널밑면에 탑재된 모사모듈의 혼합대류열전달 특성 연구)

  • Ryu, Kap-Jong;Lee, Jin-Ho;Jang, Jun-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.433-439
    • /
    • 2001
  • An experimental study was carried out on the characteristics of the mixed-convection heat transfer from a protruding heat source module which had uniform heat flux and was located on a flat plate in the inclined channel. The effects of the inclined channel(${\varphi}=0{\sim}90^{\circ}$) was studied for the input power($Q=3,\;7W$) and inlet air velocities($V_{i}=0.1{\sim}0.9m/s$). Experimental results indicate that the input power was most effective parameter on the temperature differences between inlet air and module. The effects of the inclined angle was negligible when the inlet velocities were above 0.5m/s and 0.9m/s at Q = 3W, 7W respectively. As the inclined angle of the channel increases, the temperatures of the module are decreased. So we obtained the best condition on the adiabatic board at the vertical channel.

  • PDF

A Study on the Improvement of Airflow Deflection in a Cleanroom of Class 1000 (Class 1000 클린룸에서 편류 개선에 관한 연구)

  • Noh, Kwang-Chul;Lee, Seung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.225-233
    • /
    • 2010
  • We performed 3 dimensional numerical study on the improvement of the airflow deflection in the cleanroom of Class 1000, which is presently operated for the manufacturing process in Korea. The Deflection angle and the non-uniformity were investigated to analyze the airflow characteristics and the performance of cleanroom with variations of the cleanroom occupancy state, the filters' arrangement, and the floor return air system. From the numerical results, we found out that the airflow pattern of the cleanroom is more unidirectional and stable in the condition of at-rest than in the condition of as~built. It is due to that the equipments installed in the cleanroom play a role like partitions, which prevent the airflow from inclining toward the recirculation air duct. And it is needed to arrange the filter units parallel to the equipments array without a gap between them for maintaining the unidirectional airflow pattern. Finally, we knew that it is very important to install the partition like the eyelid above the equipment to keep the unidirectional airflow around the equipments and remove the contaminants quickly.

Experimental Study on the Fire Extinguishing Characteristics of Water Mist System (미분무수 소화설비의 소화특성 실험)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Oh, Kyu-Hyung;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.78-84
    • /
    • 2009
  • We carried out fire extinguishing experiments with three kinds of water mist nozzle system. Fire extinguishing experiment according to installed nozzle height and fuel pan location was done. And fire extinguishing performance was compared with plain water and foam agent mixed solution. Water mist nozzle height was varied with 4m, 3.5m and 3m and position of fuel fan was varied 0.5m and 1m from the center of water mist nozzle. Foam agent that used in this experiment is 3% type of AFFF (Aqueous Film Forming Foam) solution. Experimental result showed the door opening effect was little. Fire extinguishing performance of foam agent mixture water mist was better than the plain water mist only.

Comparison of Condenser Characteristics using R410A and R22 under the Same Inlet Temperature Condition (동일한 유입온도조건에서 R410A와 R22 적용 응축기의 특성비교)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1049-1059
    • /
    • 2003
  • R410A is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R410A flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 16% is needed for R410A than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop decrease of 15% for R410A as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires lower electric-power consumption with R410A than that with R22.