Browse > Article

Comparison of Condenser Characteristics using R410A and R22 under the Same Inlet Temperature Condition  

김창덕 (㈜센추리 기술연구소)
이진호 (연세대학교 기계공학과)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.15, no.12, 2003 , pp. 1049-1059 More about this Journal
Abstract
R410A is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R410A flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 16% is needed for R410A than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop decrease of 15% for R410A as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires lower electric-power consumption with R410A than that with R22.
Keywords
Alternative refrigerant; R410A; Heat transfer rate; Pressure drop;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 /
[ McLinden,M.O.;Klein,S.A.;Lemmon,E.W.;Peskin,A.P. ] / Thermodynamic and transport properties of refrigerants and refrigerant mixtures database (REFPROP) (Ver. 6.01)
2 Comparison of condenser characteristics using R407C and R22 on the same inlet temperature condition /
[ Kim,C.D.;Jeon,C.D.;Lee,J. ] / Korean Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을
3 Experimental investigation of two phase flow condensation of alternatives to HCHC-22 inside enhanced surface tubing /
[ Sami,S.M.;Maltais,H. ] / Applied Thermal Engineering   ScienceOn
4 Alternatives to HCFC-22 for air conditioners /
[ Devotta,S.;Waghmare,A.V.;Sawant,N.N.;Domkundwar,B.M. ] / Applied Thermal Engineering   ScienceOn
5 Experimental investigation on condensation heat transfer and pressure drop of new HFC refrigerants /
[ Cavallini,A.;Censi,G.;Col.D.;Doretti,L.;Longo,G.A.;Rossetto,L. ] / International Journal Refrigeration   ScienceOn
6 Describing uncertainties in single sample experiments /
[ Kline,S.J.;McClintock,F.A. ] / Mechanical Engineering
7 Heat transfer characteristics in horizontal tubes for R-407C and R-410A /
[ Takashi Okazaki;Yoshihiro Sumida;Yoshiaki Tanimura ] / The International Symposium on HCFC Alternative Refrigerants
8 /
[ ASHRAE ] / Fundamental Handbook (SI)
9 Performance of a room air conditioner using R-410A according to the variation of outdoor temperature /
[ Kim,B.S.;Lee,S.H. ] / Korean Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을
10 An experimental study on condensation characteristics of slit fin-tube heat exchanger using alternative refrigerants, R407C and R410A /
[ Jeon,C.D.;Jang,K.K.;Kang,S.H.;Lee,J. ] / Korean Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을
11 Role of refrigerant mixture as alternatives to CFCs /
[ Didion,D.A.;Bivens,D.B. ] / International Journal Refrigeration   ScienceOn
12 Comparison of performance variation between R-22 and R-410A refrigeration systems /
[ Park,T.J.;Lee,M.K.;Jeon,J.H.;Jang,K.S. ] / Korean Journal of Air-Conditioning and Refrigeration Engineering   과학기술학회마을