• 제목/요약/키워드: False-negative results

Search Result 302, Processing Time 0.029 seconds

Development of SCAR Marker for Identifying Male Trees of Ginkgo biloba using Multiplex PCR (Multiplex PCR을 이용한 은행나무 수나무 식별용 SCAR 마커 개발)

  • Hong, Yong-Pyo;Lee, Jei-Wan
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.422-428
    • /
    • 2016
  • Ginkgo (Ginkgo biloba L.) is one of the most appropriate roadside trees because of a good transplantation nature and ability to grow well in urban environment. Ginkgo is a dioecious species. Sex discrimination of ginkgo is possible through comparing morphological characters of reproductive organs. However, it needs more than about twenty years for reproductive organs to appear after sexual maturity. Until now, ginkgo trees for roadside plantation have been planted without discriminating the sex because ginkgo trees have been usually planted before sexual maturity. Ginkgo nuts from the female ginkgo trees planted along the roadside emit a foul odor, and make much pollution on the streets. Thus in this study a novel SCAR marker (SCAR-GBM) for the early sex discrimination was developed. Primers were developed on the basis of the sequence of male-specific RAPD variants reported previously. False-negative problem of SCAR marker, probably caused by dominant nature, was resolved by using multiplex PCR using primers of both the SCAR-GBM and a universal primer set of atp1 region in mitochondria DNA, which resulted in improved discrimination efficiency. The results showed that DNA bands of 1,039 bp were commonly amplified by the atp1 primer set in male and female trees, and SCAR-GBM markers of 675 bp were specifically amplified only in male trees. Reproducible and specific discrimination of the multiplex PCR was finally confirmed by applying multiple male and female individuals.

Comparison of Growth Rates of Listeria Interspecies in Different Enrichment Broth (증균배지에서의 Listeria Interspecies의 경쟁생육 비교)

  • Lee, Da Yeon;Cho, Yong Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • Monitoring of Listeria monocytogenes, the causative agent of listeriosis, in food is inportant for public health. The Korean Food Standards Codex has adopted a 'zero-tolerance' policy for L. monocytogenes. The standard detection method of L. monocytogenes is based on enrichment. Thus, proper enrichment methods need to be instituted to ensure quality control of the detection procedures. In this study, the growth of L. monocytogenes and Listeria innocua as a mixed culture in Listeria enrichment broth (LEB) was monitored during artificial contamination of enrichment culture. We confirmed competitive growth or interspecies inhibitory activity of L. monocytogenes and L. innocua. Interspecies growth differences and the inhibitory activity of different inoculation and mixtures L. innocua against L. monocytogenes were examined. The concentration of L. monocytogenes must be 2.0 log CFU/mL or more than L. innocua to grow better than L. innocua. It is known that Listeria spp. and L. monocytogenes show growth difference during LEB, resulting in the risk of false-negative results. The inhibition of L. monocytogenes by L. innocua was always observed when present at lower concentrations. However, it was confirmed that L. innocua suppressed when L. monocytogenes was present at a higher concentration. Therefore if a mixture of Listeria spp. is present, detecting L. monocytogenes is difficult. Thus, a new enrichment broth to improve the detection rate of L. monocytogenes is needed.

Sensitivity of AutoPap Primary Screening System with Location-Guided Screening in Uterine Cervical Cytology (자궁목세포진에서의 AutoPap Primary Screening System with Location-Guided Screening의 민감도 검사)

  • Choi, Jong-Sun;Jang, Hoi-Sook;Kim, Hy-Sook;Chun, Yi-Kyeong;Kim, Hye-Sun;Park, Ji-Young;Park, In-Sou;Hong, Sung-Ran
    • The Korean Journal of Cytopathology
    • /
    • v.14 no.2
    • /
    • pp.60-65
    • /
    • 2003
  • Objective: The sensitivity of the AutoPap Primary Screening System with Location-Guided Screening (AutoPap LGS) for Identifying atypical cells in cervicovaginal smears was evaluated. Methods: Two hundred forty one slides with atypical cervical cytology randomly sampled were rescreened both manually and by the AutoPap LGS. The AutoPap LGS localized the atypical cells as 15 fields of view(FOVs), which were reexamined by manual review. The sensitivity was also evaluated in accordance with the cellularity of the smears. Results: The AutoPap LGS successfully processed 232 out of 241 slides. The sensitivity of the AutoPap LGS identifying the atypical cells in successfully processed slides was 97.4%(226/232). The false negative rate was 2.6%(6/232). There was no false negative case on high grade squamous intraepithelial lesion (HSIL) or squamous cell carcinoma(SCC) smears in the AutoPap LGS. The FOVs localized the diagnostic-atypical cells in 97.8%(221/226). The number of diagnostic-atypical FOVs was increased in higher-degree of atypical cytology. The AutoPap LGS localized the atypical cells in 100% of adequately cellular smears and in 92.5% even in low cellular smears. Conclusion: The AutoPap LGS showed relatively good sensitivity to detect atypical cells. It can be a valuable system to localize atypical cells, especially in HSIL or cancer slides, even in smears with low cellularity.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Diagnostic effectiveness of fine needle aspiration cytology on pediatric cervical lymphadenopathy (소아 경부 림프절 종대의 세침 흡인 세포검사의 진단적 유용성)

  • Byun, Jun Chul;Choe, Byung Kyu;Hwang, Jin-Bok;Kim, Heung Sik;Lee, Sang Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.2
    • /
    • pp.162-166
    • /
    • 2006
  • Purpose : There are few reports in Korean literature on the diagnostic efficacy of fine needle aspiration cytology(FNAC) for pediatric cervical lymphadenopathy. This study examined the diagnostic value of FNAC on cervical lymphadenopathy in children. Methods : Data from 57 pediatric patients(aged 0.3 to 14 years) who underwent FNAC due to cervical lymphadenopathy between January 2001 and March 2005 was reviewed retrospectively. Results : Reactive cervical lymphadenitis was the most common result of the FNAC(52.5 percent). Malignant disease were revealed in 14 percent of all cases. The sensitivity, specificity was 86 percent and 96 percent, respectively. The positive and negative predictive values for malignant disease was 75 percent and 98 percent, respectively. There were two false-positive cases on FNAC; one case of Langerhans cell histiocytosis, and another with infectious mononucleosis. A false-negative case on FNAC was found to be acute lymphocytic leukemia. In seven cases(12 percent), the final diagnosis was confirmed by an open biopsy after the FNAC. There were four FNAC cases where the specimen was not satisfactory for making a diagnosis(7 percent). There were no serious complications of the FNAC procedure. Conclusion : FNAC had a high diagnostic efficacy for evaluating children with cervical lymphadenopathy.

Teachers' Recognition of Victims of School Bullying Using Data from the Adolescents' Mental Health and Problem Behavior Screening Questionnaire-II Standardization Study in Korea (청소년정서행동발달검사 표준화 연구 자료를 활용한 교사의 학교폭력 피해자 인지도)

  • Hwang, Jun-Won;Bhang, Soo-Young;Yoo, Han-Ik K.;Kim, Ji-Hoon;Kim, Bong-Seog;Ahn, Dong-Hyun;Suh, Dong-Su;Cho, Soo-Churl;Bahn, Geon-Ho;Lee, Young-Sik
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.23 no.2
    • /
    • pp.69-75
    • /
    • 2012
  • Objectives : The current study was conducted in order to investigate teachers' recognition of school bullying using a nationwide database of adolescents in middle and high school in Korea. Methods : Students in the 7th to 12th grades at 23 secondary schools participated in the current study during the fall of 2009. Subjects completed the self-report form of the Adolescent Mental Health and Problem Behavior Screening Questionnaire-II (AMPQ-II) and Symptom Checklist-90 Revised (SCL-90-R). In addition, relevant teachers used the teachers' rating scale of the AMPQ-II to report their students' status. Differences in the number of bullied students between teachers' recognition and students' report were explored. Results : A total of 2270 subjects provided relevant responses to the questionnaire. While the one-month prevalence of victimization according to students' self-reports was 28.9%, the recognized prevalence by teachers was only 10.6%. For prediction of the presence of school bullying according to students' self reports on the AMPQ-II, item 7 of the teachers' report on the AMPQ-II showed a sensitivity of 16%, a specificity of 92%, a positive predictability of 44%, a negative predictability of 72%, a false positive rate of 8%, a false negative rate of 84%, and an accuracy of 69%, respectively. No significant differences in subscores of students' self reports of the AMPQ-II and SCL-90-R were observed between bullied students who were recognized by teachers and those who were not recognized. In stepwise discriminant analysis, classification of teachers' item 2 and item 7 on the AMPQ-II with respect to school bullying according to students' reports showed an accuracy of 63.4%. Using this model, 75.2% of non-victimized subjects were classified correctly, while only 35.2% of victimized subjects were classified correctly. Conclusion : Despite the high prevalence in Korea, teachers' recognition of school violence among their students remains low. Pre-professional and continuing education to improve teachers' understanding of school bullying and knowledge of effective classroom-based prevention activities should be encouraged.

A Study on the Influence of Digital Experience and Purchase in the 4th Industrial Revolution : Focusing on Differences between Satisfied, Neutral, and Dissatisfied Groups

  • Jung, Sang Hee;Lee, Sang-Jik
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.4
    • /
    • pp.51-69
    • /
    • 2019
  • One of the most considerate phenomena of the era of the Fourth Industrial Revolution is the use of digital devices. Digitalization is rapidly advancing through all areas of industry and life. Customer journey with digitalization is looking totally different from previous customer journey. The research targets were users of fashion, automobiles, cosmetics and online shopping malls. We analyzed 300 people for each valid questionnaire. The results of the study are as follows. First, it has been proven that digital experience affects positive (+) impact on purchasing intention and positive (+) impact on recommending intention and negative impact (-) on switching intent and subsequently affects positive impact (+) to purchase and incase of switching intent, negative impact (-) to purchase. Unlike traditional methods such as SPC(Service Profit Chain), the Digital experience to Purchase process Chain (DPC) has been identified to be suitable in the digital age. Second, the digital satisfied group (5 score-very satisfaction) has shown same result as above. However the digital neutral group (even though 4 score- satisfaction in five-point scale), specially in a highly competitive industry, has different from the satisfied group and 3 score-normal is same as dissatisfied group. It means that this group is that If there is a high level of attractiveness of substitute goods, there is a high possibility of switching them. It has supported Jones and Sasser [1995] that there have been two types of loyalty of true long-term loyalty and what we call false loyalty in the highly competitive industry zone which is commoditization or low differentiation, many substitutes, low cost of switching. Identifying true loyalty and false loyalty is crucial to establishing a customer experience strategy. it is necessary to actively utilize long-term digital experiences strategy to increase the total satisfaction of digital experience through all of customer purchasing journey in order to enhance the digital customer experience. It is difficult to see the effect as a one-time event. It should be scaled over the entire customer purchase process over a long period of time, which can positively affect purchase intention, recommendation intention, and conversion intention. This is also why it is difficult for second-runners to overtake first-runners in a short period.

The Prevention of Carryover in the Automated System With Fixed Tips (자동 분주기 Fixed Tip의 Carryover 방지를 위한 개선 방안)

  • Hwang, Bo-Ra;Au, Doo-Hee;Bae, Jin-Su;Park, Jong-O;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.181-184
    • /
    • 2009
  • Purpose: Automated system that immunoassay examination are used widely. However, sample to sample carryover can cause that the next patient sample is false positive. Materials and Methods: We test HBs Ag, HBs Ab, HBc Ab(IgG) with Automated pipetting system (Tecan). It was placed with very high concentrations followed by saline solution. During this experiment, The fixed tip of Automated system wash With 0.25 moL/L NaOH. The Measurement results of saline solution confirm the occurrence of carryover. Results: Results of saline solution with 0.25 moL/L NaOH cleaning process was measured 100% negative, And results of patient serum with 0.25 moL/L NaOH cleaning process is similar reported results. Conclusion: As Results, 0.25 moL/L NaOH cleaning process was avoid carryover in experiment, And we know results of the hepatitis test did not affected by this solution we recommend 0.25 moL/L NaOH cleaning process as the Prevention of carryover in the automated system with fixed Tips.

  • PDF

A Recidivism Prediction Model Based on XGBoost Considering Asymmetric Error Costs (비대칭 오류 비용을 고려한 XGBoost 기반 재범 예측 모델)

  • Won, Ha-Ram;Shim, Jae-Seung;Ahn, Hyunchul
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.127-137
    • /
    • 2019
  • Recidivism prediction has been a subject of constant research by experts since the early 1970s. But it has become more important as committed crimes by recidivist steadily increase. Especially, in the 1990s, after the US and Canada adopted the 'Recidivism Risk Assessment Report' as a decisive criterion during trial and parole screening, research on recidivism prediction became more active. And in the same period, empirical studies on 'Recidivism Factors' were started even at Korea. Even though most recidivism prediction studies have so far focused on factors of recidivism or the accuracy of recidivism prediction, it is important to minimize the prediction misclassification cost, because recidivism prediction has an asymmetric error cost structure. In general, the cost of misrecognizing people who do not cause recidivism to cause recidivism is lower than the cost of incorrectly classifying people who would cause recidivism. Because the former increases only the additional monitoring costs, while the latter increases the amount of social, and economic costs. Therefore, in this paper, we propose an XGBoost(eXtream Gradient Boosting; XGB) based recidivism prediction model considering asymmetric error cost. In the first step of the model, XGB, being recognized as high performance ensemble method in the field of data mining, was applied. And the results of XGB were compared with various prediction models such as LOGIT(logistic regression analysis), DT(decision trees), ANN(artificial neural networks), and SVM(support vector machines). In the next step, the threshold is optimized to minimize the total misclassification cost, which is the weighted average of FNE(False Negative Error) and FPE(False Positive Error). To verify the usefulness of the model, the model was applied to a real recidivism prediction dataset. As a result, it was confirmed that the XGB model not only showed better prediction accuracy than other prediction models but also reduced the cost of misclassification most effectively.

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF