• Title/Summary/Keyword: Fall work

Search Result 287, Processing Time 0.029 seconds

A Study on the Prevention of Fall Accident for on the Roof in Rail road Vehicle (철도차량 옥상 작업시 추락사고 예방에 관한연구)

  • An, Jong-Gon;Won, Bong-Eui;Kim, Dong-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.58-68
    • /
    • 2007
  • Thorough preparations and investigations must be done in order to prevent the hazards which will happen when workers work on the roof of the rolling stocks. Some industrial disasters can be prevented by solving the risks involved in the working of the work processes. Falling accidents tend to happen from the roof of the trains when workers work in the high position. So through the analysis of the 4M( Man. Machine, Media, Management), this paper analyzed the risk factors among the roof works and all problems of the maintenance. Also this paper suggests new devices or new methods to prevent falling disasters and to relieve the mental senses of uneasiness.

  • PDF

Variation Trends of Population and industrial Accidents involved Middle-aged & Aged Workers in Recent Years (근년 인구변동추이와 중고령 근로자의 산업재해발생경향)

  • 임현교
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.194-199
    • /
    • 2001
  • The present situation of Korea already shone various symptoms of the aged society, and many kinds of data reported by the National Statistical Office demonstrate those facts. However, to my regret, sufficient efforts for aged workers are not taken in the area of industrial safety. In this research, work arrangement and industrial accidents of middle-aged and aged workers over last 5 years were analyzed. According to research results, proportion of industrial accidents involved middle-aged and aged workers was as high as 40%, and that of aged workers alone was so high as 25%. In addition, proportion of accidents were higher than that of worker population f3r aged wetters. Considering ages, it was demonstrated that as workers get older, mean number of accidents shows the tendency of going higher, and that as years go by, mean lost work-days are increasing regardless of age group. Main accident types were Fall followed by Slip, and Work-Related Disease, furthermore proportion of Slip was highest than any other types for aged workers. Based upon these results, it was emphasized thai careful attention should be paid to functional characteristics of aged workers, and that modification of accident prevention policy would be necessary.

  • PDF

A Study on the Costume Work Applying Kkot Mun(Floral Doors) (꽃문을 응용한 의상 작품 제작에 관한 연구)

  • Moon, Myeng-Ok
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.270-277
    • /
    • 2007
  • Buddhist temples and halls signify paradise on earth. Buddhist sutras refer to paradise as a place where flowers fall down like snow, fragrance and music fill the air, flowers blossom and butterflies fly. The Kkot Mun of Buddhist temples are an essential part of the creation of this paradise and are ornamented with elaborate sculptures of flowers and animals. The ornamentation of the Kkot Mun is truly admirable for its artistry and beauty. Although the Kkot Mun is an element of Korean traditional Buddhist architecture, it could also be applied to costume work. I thought the characteristic elements of the Kkot Mun for the costume work were the flower, the lattice and the transparent effect that was made with the lattice and Dagjongee. I used the technique of strap cutting, strap twisting and cut-out for the lattice of Kkot Mun and flower making, knitting, cut-out and quilting for the flower of Kkot Mun. I represented the transparent effect of Kkot Mun with the lapped materials. I selected six remarkable Kkot Mun of Korean temples, revised shapes of these and made six costume works. These six costume works would be the suggestion of costume design if an element of Korean traditional architecture was applied to modern costume making.

Risk Factors for Falls among the Community-Dwelling Elderly in Korea

  • Sohng Kyeong-Yae;Moon Jung-Soon;Song Hae-Hiang;Lee Kwang-Soo;Kim Young-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.8
    • /
    • pp.1483-1490
    • /
    • 2004
  • Community-based centres were surveyed to determine the frequency of and risk factors for falls among elderly Koreans. We examined fall-related risk factors, including physiological and physical health, psychosocial functions, self-reported physical capacity and activity, vision, and the use of medication, among 351 elderly people aged 65 years or older, with ambulatory. Forty-two per cent of elderly Korean subjects reported at least one episode of falling in the previous 12 months, $38\%$ of whom had consequences that required either the attention of a physician or hospitalization. Factors significantly associated with an increased risk of falling were a restricted activity during the previous five years (adjusted OR 1.3), use of alternative therapy (adjusted OR 2.7), low knee flexor and extensor-muscle strength (adjusted OR 1.21 and 1.20), and poor balance with closed eyes (adjusted OR 8.32). We conclude that falls among older persons living in the community are common in Korea and that indicator of bad health and frailty or variables directly related to neuromuscular impairment are significant predictors of the risk of falling.

Characteristic and Development of All-in-one Shock Energy Absorber Lanyard Protection Tube used Super Fibers (슈퍼 섬유를 활용한 일체형 Shock Energy Absorber Lanyard Protection Tube 제조 및 특성분석)

  • Cho, Jin Won;Kwon, Sang Jun;Kim, Sang Tae;Yeum, Jeong Hyun;Kang, Ji Man;Ji, Byung Chul
    • Textile Coloration and Finishing
    • /
    • v.26 no.2
    • /
    • pp.106-113
    • /
    • 2014
  • Work-related falls are a major problem in the construction and roofing industries. To avoid serious injury to the worker caused by high decelerations or forces, different systems to absorb the energy of a fall are implemented in personal protective equipment. In this study, shock energy absorber lanyard protection tube was prepared using high tenacity PET fiber, P-aramid fiber, and UHMWPE fiber, respectively. Dynamic load test and static load test, bursting strength test based on the Korea fall protection equipment standard(Korea Occupational Safety & Health Agency standard 2013-13) or conformity European safety test(CE : EN355) were conducted. Especially maximum arrest force by dynamic load test of energy absorber showed below 6,000N.

Femoral Fracture load and damage localization pattern prediction based on a quasi-brittle law

  • Nakhli, Zahira;Ben Hatira, Fafa;Pithioux, Martine;Chabrand, Patrick;Saanouni, Khemais
    • Structural Engineering and Mechanics
    • /
    • v.72 no.2
    • /
    • pp.191-201
    • /
    • 2019
  • Finite element analysis is one of the most used tools for studying femoral neck fracture. Nerveless, consensus concerning either the choice of material characteristics, damage law and /or geometric models (linear on nonlinear) remains unreached. In this work, we propose a numerical quasi-brittle damage model to describe the behavior of the proximal femur associated with two methods to evaluate the Young modulus. Eight proximal femur finite elements models were constructed from CT scan data (4 donors: 3 women; 1 man). The numerical computations showed a good agreement between the numerical curves (load - displacement) and the experimental ones. A very encouraging result is obtained when a comparison is made between the computed fracture loads and the experimental ones ($R^2=0.825$, Relative error =6.49%). All specific numerical computation provided very fair qualitative matches with the fracture patterns for the sideway fall simulation. Finally, the comparative study based on 32 simulations adopting linear and nonlinear meshing led to the conclusion that the quantitatively results are improved when a nonlinear mesh is used.

A Study on Environment, Care Process, and Patient-related Factors Associated with Patient Falls - A Retrospective Study of Inpatient Falls in the Unit of General Medicine in the United States (환자낙상에 영향을 주는 환경, 의료과정, 그리고 환자 관련 요소에 관한 연구 - 미국의 일반내과병동 환자낙상 데이터 분석을 통한 후향성 연구)

  • Choi, Young-Seon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • Purpose: The main objective of this paper is, to assess environment, care process, and patient-related factors associated with patient falls. The study also aims at identifying various factors that would affect inpatient falls and, therefore, helping both caregivers and designers contribute to better prevent inpatient falls in their own areas of expertise. Methods: A retrospective analysis of inpatient falls that occurred in the unit of General Medicine in the United States has been conducted and environment, care process, patient-related factors associated with those falls have been analyzed at the same time. Results: The study identified several factors associated with inpatient falls. They range from environmental factors to care process- and patient-related factors. Patient visibility and patient accessibility can matter to patient falls and where those falls occur, along with patient days per room, the percentage of patient days with high fall risk patients per room, the percentage of high fall risk patients per room. Implications: The findings of the study can provide design implications that can be incorporated into design process and design decisions to promote fall prevention in inpatient care units. Inpatient falls can be effectively reduced when caregivers and designers work together to understand the complex nature of inpatient falls and the importance of multidisplinary efforts among various experts in the areas of healthcare.

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Evaluation of Wearing Comfort and Ease of Working Pants for Improved Mobility (동작가동성이 향상된 작업복 하의 개발을 위한 시판 제품의 착용감 및 여유량 평가)

  • Lee, Hyojeong;Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.4
    • /
    • pp.752-770
    • /
    • 2017
  • This study provides a size specification and ease for the development of pants for working clothes in the construction industry according to season. We collected and measured the size specification of 4 types of Spring/Fall pants, 4 types of winter brushed bonding pants, and 4 types of winter padded pants. Subjective comfort evaluation and analysis of ease sensation were performed for all products on 12 subjects. The average size specifications for the pants according to seasons were as follows. Spring/Fall pants had 74.0/80.0cm waist size (relaxed/maximum stretched) and 104.0cm hip size. Winter brushed bonding pants had 76.0/83.4cm for waist size and 106.0cm for hip size. Winter padded pants had 71.5/84.0cm for waist size and 112.8cm for hip size. When designing a pattern by comparing product size specification and subject body size, the recommended ease is 0.2/7.2cm for waist size (relaxed, maximum stretched) and 13.6cm for hip size for Spring/Fall pants, and 0.2/6.2cm for waist size and 11.6cm for hip size of winter brushed bonding pants, and -5.3/7.2cm for waist size and 19.4cm for the hip size of winter padded pants.

Uniform large scale cohesionless soil sample preparation using mobile pluviator

  • Jamil, Irfan;Ahmad, Irshad;Ullah, Wali;Junaid, Muhammad;Khan, Shahid Ali
    • Geomechanics and Engineering
    • /
    • v.28 no.5
    • /
    • pp.521-529
    • /
    • 2022
  • This research work deals with the development of air pluviation method for preparing uniform sand specimens for conducting large scale laboratory testing. Simulating real field conditions and to get reliable results, air pluviation method is highly desirable. This paper presents a special technique called air pluviation or sand raining technique for achieving uniform relative density. The apparatus is accompanied by a hopper, shutters with different orifice sizes and numbers and set of sieves. Before using this apparatus, calibration curves are drawn for relative density against different height of fall (H) and shutter sizes. From these calibration curves, corresponding to the desired relative density of 60%, the shutter size of 13mm and height of fall of 457.2 mm, are selected and maintained throughout the pluviation process. The density obtained from the mobile pluviator is then verified using the Dynamic Cone Penetrometer (DCP) test where the soil is poured in the box using defined shutter size and fall height. The results obtained from the DCP test are averaged as 60±0.5 which was desirable. The mobile pluviator used in this research is also capable of obtaining relative densities up to 90%. The instrument is validated using experimental and numerical approach. In numerical study, Plaxis 3D software is used in which the soil mass is defined by 10-Node tetrahedral elements and 6-Node plate is used to simulate plate behavior in the validation phase. The results obtained from numerical approach were compared with that of experimental one which showed very close correlation.