• Title/Summary/Keyword: Failure line

Search Result 835, Processing Time 0.027 seconds

Vulnerability Assessment Procedure for the Warship Including the Effect of Shotline and Penetration of Fragments (탄두의 관통 효과를 고려한 함정 취약성 평가 절차에 관한 기본 연구)

  • Kim, Kwang-Sik;Lee, Jang-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.3
    • /
    • pp.254-263
    • /
    • 2012
  • The survivability of warship is assessed by susceptibility, vulnerability and recoverability. Essentially, a vulnerability assessment is a measure of the effectiveness of a warship to resist hostile weapon effects. Considering the shot line and its penetration effect on the warship, present study introduces the procedural aspects of vulnerability assessments of warship. Present study also considers the prediction of penetration damage to a target caused by the impact of projectiles. It reflects the interaction between the weapon and the target from a perspective of vulnerable area method and COVART model. The shotline and tracing calculation have been directly integrated into the vulnerability assessment method based on the penetration equation empirically obtained. A simplified geometric description of the desired target and specification of a threat type is incorporated with the penetration effect. This study describes how to expand the vulnerable area assessment method to the penetration effect. Finally, an example shows that the proposed method can provide the vulnerability parameters of the warship or its component under threat being hit through tracing the shotline path thereby enabling the vulnerability calculation. In addition, the proposed procedure enabling the calculation of the component's multi-hit vulnerability introduces a propulsion system in dealing with redundant Non-overlapping components.

An Analysis on the Deployment Methods for Smart Monitoring Systems (스마트 모니터링 시스템의 배치 방식 분석)

  • Heo, No-Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.55-62
    • /
    • 2010
  • Monitoring systems are able to report certain events at region of interest(ROI) and to take an appropriate action. From industrial product line full of robots to fire detection, intrusion detection, smart grid application, environmental pollution alarm system, monitoring system has widely used in diverse industry sector. Recently, due to advance of wireless communication technology and availability of low cost sensors, intelligent and/or smart monitoring systems such as sensor networks has been developed. Several deployment methods are introduced to meet various monitoring needs and deployment performance criteria are also summarized to be used to identify weak point and be useful at designing monitoring systems. Both efficiency during deployment and usefulness after the deployment should be assessed. Efficiency factors during deployment are elapsed time, energy required, deployment cost, safety, sensor node failure rate, scalability. Usefulness factors after deployment are ROI coverage, connectivity, uniformity, target density similarity, energy consumption rate per unit time and so on.

Use of IMS-RT-PCR for the Rapid Isolation and Detection of Hepatitis A Virus from the Swine Feces (IMS-RT-PCR을 활용한 육성돈 분변으로부터 간염 A형 바이러스의 신속순수분리 및 검출법 연구)

  • Lee, Hee-Min;Kim, Duwoon
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.638-642
    • /
    • 2012
  • Human pathogenic viruses such as hepatitis A and E virus (HAV and HEV), which lead to acute liver failure and death, are foodborne pathogens associated with the consumption of virus-contaminated meats, filter-feeding bivalves, fruits, and salads. Two of the three swine farms examined in this study had HAV and HEV positive stool samples in a nested RT-PCR assay. The use of the immunomagnetic separation (IMS) facilitated the separation of HAV through interactions between the ligand on the virion surface and the antibody from the swine feces containing both HAV and HEV. The nested RT-PCR analysis was performed for the detection of HAV obtained from hepatocarcinoma cell line (PLC/PRF/5) contaminated with eluent fraction of IMS. This indicated that IMS has the potential to simultaneously isolate and concentrate target viruses by changing antibodies linked on the magnetic beads.

Operation and Command of Virtual Router Redundancy Protocol in Open N2OS (Open N2OS를 활용한 가상 라우터 이중화 프로토콜의 기능 동작과 명령어)

  • Lee, ChangSik;Ryu, HoYong;Park, Jaehyung
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.693-700
    • /
    • 2018
  • Virtual router redundancy protocol (VRRP) was designed as a solution to support fast fail-over in case of network failure. There exists virtual router which acts as default gateway in LAN, and the virtual router is dynamically elected between master and backup router. Through this protocol, end-hosts can be provided seamless network service. However, it needs expensive license fees and maintenance costs to adopt current commercial network operating systems. Furthermore, they are commonly enterprise proprietary software and inherently closed source. In order to tackle these problem, Open N2OS which is open source based open network software platform was developed. It has no dependency on hardware equipment, and provides high availability, scalability, various networking functions. In this paper, we handle VRRP operation and mechanism with related command line interface (CLI).

A 12-kV HBM ESD Power Clamp Circuit with Latchup-Free Design for High-Voltage Integrated Circuits (고전압 집적회로를 위한 래치업-프리 구조의 HBM 12kV ESD 보호회로)

  • Park, Jae-Young;Song, Jong-Kyu;Jang, Chang-Soo;Kim, San-Hong;Jung, Won-Young;Kim, Taek-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The holding voltage of high-voltage devices under the snapback breakdown condition has been known to be much smaller than the operating voltage. Such characteristics cause high-voltage ICs to be susceptible to the transient latch-up failure in the practical system applications, especially when these devices are used as the ESD(ElectroStatic Discharge) power clamp circuit. A new latchup-free design of the ESD power clamp circuit with stacked-bipolar devices is proposed and successfully verified in a $0.35{\mu}m$ 3.3V/60V BCD(Bipolar-CMOS-DMOS) process to achieve the desired ESD level. The total holding voltage of the stacked-bipolar devices in the snapback breakdown condition can be larger than the operating voltage. Proposed power clamp operates safely because of the high holding voltage. From the measurement on the devices fabricated using a $0.35{\mu}m$ BCD Process, it was observed that the proposed ESD power clamp can provide 800% higher ESD robustness per silicon area as compared to the conventional clamps with a high-voltage diode.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.

Nonlinear Analysis of RC Members Using Truss Model (트러스 모델을 이용한 철근콘크리트 부재의 비선형해석)

  • Eom, Tae-Sung;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.177-188
    • /
    • 2006
  • Conventional nonlinear finite element analysis requires complicated modeling and analytical technique. Furthermore, it is difficult to interpret the analytical results presented as the stress-strain relationship. In the present study, a design-oriented analytical method using the truss model was developed. A reinforced concrete member to be analyzed was idealized by longitudinal, transverse, and diagonal line elements. Basically, each element was modeled as a composite element of concrete and re-bars. Simplified cyclic models for the concrete and re-bar elements were developed. RC beams and walls with various reinforcement details were analyzed by the proposed method. The inelastic strength, energy dissipation capacity, deformability, and failure mode predicted by the proposed method were compared with those of existing experiments. The results showed that the proposed model accurately predicted the strength and energy dissipation capacities, and to predict deformability of the members, the compression-softening model used for the concrete strut element must be improved.

A STUDY ON THE MARGINAL FIDELITIES AND FRACTURE STRENGTH OF IPS EMPRESS $2^(R)$ CERAMIC CROWNS (IPS Empress $2^(R)$를 이용한 전부도재관의 변연적합성과 파절강도에 관한 연구)

  • Yu, Ji-Hyoung;Kim, Yong-Cheol;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.606-617
    • /
    • 2000
  • The purpose of this study was to measure the marginal fidelities and the fracture strength of IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$ ceramic crowns. After constructed of 12 experimental dies for each group, ceramic crowns were fabricated on the metal master dies prepared on the maxillary right premolar Marginal gaps were measured on the specimen between the margin of each crown and finish-ing line of the metal master die by using stereo-microscope($SZ-ST^{(R)}$ Olympus, Japan) and all specimens were cemented on the metal master die with Bistite $II^{(R)}$ (Tokuyama soda Co, LTD., Japan) resin cement. Finally marginal gaps were measured again. To measure of the fracture strength, buccal incline on the functional cusp of specimens were loaded until the catastrophic failure occurred by using the AGS-1000 $D^{(R)}$(Shimadzu, Japan). The result of marginal fidelities and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows : 1. No significant difference was found in the mean marginal fidelities and fracture strength between the IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$. 2. In comparison of marginal fidelities between before and after cementation, there was significant difference(P<0.05). The IPS Empress 2 system was shown in this study that had good marginal fidelities and fracture strength compared to In-Ceram ceramics. Although this system was acceptable to clinical applications, the system still has to be considered long-term researches about marginal fidelities and fracture strength due to the lack of data about the clinical researches.

  • PDF

A study on structure analysis system for short fiber reinforced plastics (단섬유강화 플라스틱 복합재료 구조해석 기법연구)

  • Youn, Jee-Young;Kim, Sang-Woo;Park, Bong-Hyun;Lee, Seong-Hoon;Kwon, Tai-Hun;Kim, Ki-Tae
    • Composites Research
    • /
    • v.24 no.4
    • /
    • pp.41-47
    • /
    • 2011
  • This paper deals with anisotropic property and structural analysis for short fiber reinforced plastic composites manufactured by the injection molding process. The common approach for modeling this type of material is the consideration of the material as homogenous and isotropic. However, the common isotropy approach often results in unexpected failure. To overcome this, new structure analysis methodology was developed in order to consider fiber orientation effect using injection mold flow analysis and Halpin-Tsai equations for unidirectional composites and taking an orientation average. The numerical predictions are compared to experimental data for tensile specimen. The predicted mechanical properties agree well with experimental data for fiber orientation and weld line effect. The analysis system was also applied to an automobile part. The proposed anisotropic model predicted different mechanical properties by position of the part and different mechanical performance of the part was changed according to injection gate position.

The study on the possibility of performance analysis for the compressive member using the numerical method (수치해석법을 활용한 압축부재 성능 해석의 가능성에 대한 연구)

  • Kim, Gwang-Chul
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.1
    • /
    • pp.26-39
    • /
    • 2010
  • This is a leading study to replace the structural analysis methodology on the specific traditional joint by a numerical analysis. Tests were carried out to test the compressive methodologies with the numerical results. The Japanese larch was used as a sample. The Orthotropic property of wood was specifically considered for the finite element numerical analysis. Linear numerical analysis and non-linear numerical analysis for the BEAM element and the two SOLID elements of ANSYS were used to analyze the compressive performance. In addition, more finely divided elements were used to raise the accuracy of the numerical result. Finally, the statistically significant differences were tested between that of the analytical and numerical results. It could be concluded that the SOLID 64 element shows the most optimum result when the non-linear analysis with the more finely divided element was used. However, finely dividing of the element is a considerable time consuming process, and it is quite difficult to raise the accuracy of the non-linear numerical analysis. Therefore, if considering the vertical displacement to be of the only interest, the BEAM element is more efficient than the SOLID element because the BEAM element is reflected as a simple line, which is less time consuming and difficult in dividing the elements. But, the BEAM element cannot accurately model the knot as a strength defect factor which is an important property in the orthotropic property of wood. Therefore, the SOLID element should be used to model the strength defect factor, knot, as it can be efficiently applied on the structural size flexure member which could be more strongly effected by the knot. In addition, it is useful at times when the failure types of members are to be more closely investigated, as the SOLID element is able to examine the local stress distribution of the member. The conclusion drawn by this study is of the good concordance between analytical results and numerical results of compressive wood members, but how orthotropic properties should only be considered. The numerical analysis on the specific Korean traditional joints will be based on the current study results.

  • PDF