• 제목/요약/키워드: Failure Isolation

검색결과 135건 처리시간 0.024초

지진격리된 원전배관의 지진취약도 분석 (Seismic Fragility Analysis of Base Isolated NPP Piping Systems)

  • 전법규;최형석;함대기;김남식
    • 한국지진공학회논문집
    • /
    • 제19권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Base isolation is considered as a seismic protective system in the design of next generation Nuclear Power Plants (NPPs). If seismic isolation devices are installed in nuclear power plants then the safety under a seismic load of the power plant may be improved. However, with respect to some equipment, seismic risk may increase because displacement may become greater than before the installation of a seismic isolation device. Therefore, it is estimated to be necessary to select equipment in which the seismic risk increases due to an increase in the displacement by the installation of a seismic isolation device, and to perform research on the seismic performance of each piece of equipment. In this study, modified NRC-BNL benchmark models were used for seismic analysis. The numerical models include representations of isolation devices. In order to validate the numerical piping system model and to define the failure mode, a quasi-static loading test was conducted on the piping components before the analysis procedures. The fragility analysis was performed by using the results of the inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using the shell finite element model of a piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. In addition, the collapse load point was used for the failure mode for the fragility analysis.

Two-Faults Detection and Isolation Using Extended Parity Space Approach

  • Lee, Won-Hee;Kim, Kwang-Hoon;Park, Chan-Gook;Lee, Jang-Gyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.411-419
    • /
    • 2012
  • This paper proposes a new FDI(Fault Detection and Isolation) method, which is called EPSA(Extended Parity Space Approach). This method is particularly suitable for fault detection and isolation of the system with one faulty sensor or two faulty sensors. In the system with two faulty sensors, the fault detection and isolation probability may be decreased when two faults are occurred between the sensors related to the large fault direction angle. Nonetheless, the previously suggested FDI methods to treat the two-faults problem do not consider the effect of the large fault direction angle. In order to solve this problem, this paper analyzes the effect of the large fault direction angle and proposes how to increase the fault detection and isolation probability. For the increase the detection probability, this paper additionally considers the fault type that is not detected because of the cancellation of the fault biases by the large fault direction angle. Also for the increase the isolation probability, this paper suggests the additional isolation procedure in case of two-faults. EPSA helps that the user can know the exact fault situation. The proposed FDI method is verified through Monte Carlo simulation.

한의과대학생의 유급경험에 관한 현상학적 연구 (The phenomenological study on the Experience of Korean Medicine Students who have academic failure)

  • 신헌태
    • 대한예방한의학회지
    • /
    • 제20권2호
    • /
    • pp.53-67
    • /
    • 2016
  • Objectives : The aim of this study was to explore the academic failure experiences of Korean Medicine Students. The academic failure in a medical school is defined as the situation the student who have academic failure need to repeat their academic year again. Methods : Data were collected through in-depth individual interviews from April to May 2016 and analyzed through Colaizzi's phenomenological methodology. The participants were interviewed twice, for 30minutes to 60minutes per interview. Results : Eight theme-clusters of were identified from 21 themes. The theme-clusters were 'Dream of university life and freedom', 'Meeting Stranger academic field and growing study stress', 'Difficulty of self-management', 'Weak supporting system', 'Feeling of guilty, sense of isolation and decreasing in self-esteem', 'The experience during the vacation after the academic failure', 'The experience of returning to school' and 'Self growing through hard experience'. Conclusions : Understanding of academic failure experience of Korean Medicine Students is an important approach to counsel them and an important way to reach a good model of education at a medical college.

중약진 지역에서의 지진격리교량의 비용효율성 평가 (Cost Effectiveness Evaluation of Seismic Isolated Bridges in Low and Moderate Seismic Region)

  • 고현무
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.440-447
    • /
    • 2000
  • In order to evaluate the cost effectiveness of seismic isolation for bridges in low and moderate seismic region, a method of calculation minimum life-cycle cost of seismic-isolated bridges under specific acceleration level and soil condition is developed. Input ground motion is modeled as spectral density function compatible with response spectrum for combination of acceleration coefficient and site coefficient. Failure probability is calculated by spectrum analysis based on random vibration theories to simplify repetitive calculations in the minimization procedure. Ductility of piers and its effects on cost effectiveness are considered by stochastic linearization method. Cost function and cost effectiveness index are defined by taking into consideration the characteristics of seismic isolated bridges. Limit states for calculation of failure probability are defined on superstructure, isolator and pier, respectively. The results of example design and analysis show that seismic isolation is more cost-effective in low and moderate seismic region than in high seismic region.

  • PDF

상수관망의 부분적 격리를 위한 제수밸브 탐색 알고리듬 (An Algorithm for Searching On-Off Valves to Isolate a Subsystem in a Water Distribution System)

  • 전환돈;김중훈
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.35-43
    • /
    • 2006
  • Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate a subsystem due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves. Minimizing the pipe failure impact, an efficient algorithm is required to identify adjacent valves quickly. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network when a pipe failure is presented. The algorithm is operated on a matrix called the valve location matrix containing the information of valve locations. An application to an existing water distribution system demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.

유도전동기를 위한 관측기 기반의 고장 감지 및 분리 기법 설계 (Design of Observer-Based Fault Detection and Isolation techniques for Induction Motors)

  • 한병조;박기광;구경완;양해원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.77-79
    • /
    • 2009
  • Nonlinear system fault detection and isolation of this paper is about the failure of unknown function approximation using neural network for fault detection and isolation techniques of induction motors were applied. observer-based fault signal residual value was used. Induction motor using the speed controller of the backstepping controller. Proposed fault detection and isolation to prove the performance of the simulation was applied to and the actual system.

  • PDF

Satellite Fault Detection and Isolation Scheme with Modified Adaptive Fading EKF

  • Lim, Jun Kyu;Park, Chan Gook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1401-1410
    • /
    • 2014
  • This paper presents a modified adaptive fading EKF (AFEKF) for sensor fault detection and isolation in the satellite. Also, the fault detection and isolation (FDI) scheme is developed in three phases. In the first phase, the AFEKF is modified to increase sensor fault detection performance. The sensor fault detection and sensor selection method are proposed. In the second phase, the IMM filer with scalar penalty is designed to detect wherever actuator faults occur. In the third phase of the FDI scheme, the sub-IMM filter is designed to identify the fault type which is either the total or partial fault. An important feature of the proposed FDI scheme can decrease the number of filters for detecting sensor fault. Also, the proposed scheme can classify fault detection and isolation as well as fault type identification.

비례적분(PI) 관측기를 이용한 시스템의 고장진단 (Fault Detection and Isolation of System Using Multiple Pi Observers)

  • Kim, H.S.;Kim, S.B.;Shigeyasu Kawaji
    • 한국정밀공학회지
    • /
    • 제14권2호
    • /
    • pp.41-47
    • /
    • 1997
  • Fault diagnosis problem is currently a subject of extensive research in the control field. Although there are several works on the fault detection and isolation observers and the residual generators, those are con- cerned with only the detection of actuator failures or sensor failures. So, the perfect detection and isolation for the actuator and sensor failures is strongly required in the field of the practical applications. In this paper, a strategy of fault diagnosis using multiple proportional integral (PI) observers including the magnitude of actuator failures is provided. It is shown that actuator failures are detected and isolated perfectly by monitoring the integrated error between actual output and estimated output by a PI observer. Also in presence of complex actuator and sensor failures, these failures are detected and isolated by multiple PI observers.

  • PDF

면진장치를 설치한 회전기기의 지진취약도 개선효과 분석 (Analysis of Seismic Fragility Improvement Effect of an Isolated Rotational Equipment)

  • 김민규;대조정수;전영선;최인길
    • 한국지진공학회논문집
    • /
    • 제11권6호
    • /
    • pp.69-78
    • /
    • 2007
  • 본 연구에서는 원자력발전소 비상디젤발전기의 내진안전성을 정량적으로 평가하기 위하여 지진취약도 분석방법을 제안하고 제안한 방법을 이용하여 비상디젤발전기의 지진취약도를 평가하여 정량적인 지진위험도를 제시하였다. 기존의 비상디젤발전기뿐만 아니라 면진장치를 설치하여 지진력 저감효과를 증대시킨 비상디젤발전기에 대한 지진취약도 분석을 함께 수행하여 비상디젤발전기와 같은 대형 회전기기의 경우 면진장치를 통한 지진취약도의 변화를 살펴보았다. 최종적으로 지진취약도 결과를 이용하여 HCLPF값의 변화를 비교하여 면진에 의하여 비상디젤발전기의 취약도를 크게 개선 할 수 있는 것을 알 수 있었으며, 면진된 경우 면진장치의 파괴가 전체 거동을 지배하므로 면진장치의 성능개선이 필요한 것을 알 수 있었다.

등대구조물의 면진시스템 적용방안 연구 (Application of Isolation System to the Lighthouse Structure)

  • 허무원;천영수;김동영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.27-36
    • /
    • 2013
  • 본 연구에서는 등대 구조물을 대상으로 한 면진기술 적용방안을 제시함으로써 지진에 대해 무방비상태에 놓여 있는 등대구조물의 지진안전도 확보방안을 제시하였다. 또한, 제안된 면진기술 적용방안을 활용하여 내진설계 이전에 지어진 등대를 대상으로 등대전체를 면진하였을 경우와 등대 렌즈만을 면진하였을 경우에 대하여 면진효과를 분석해 보았다. 해석결과, 등대 전체를 면진화하였을 경우 최대응답가속도와 층전단력 측면에서 충분한 면진효과를 얻은 반면, 등대 렌즈만을 면진화한 경우에는 렌즈부의 면진효과는 유효한 것으로 나타났으나 등대 자체의 안전이 확보되지 못한 상황에서는 등대의 파괴가 선행될 가능성이 있음에 주의할 필요가 있는 것으로 나타났다. 또한 등대전체와 렌즈를 동시에 면진화한 경우 비 면진구조 대비 유효한 면진효과는 나타내었지만, 최대응답가속도가 등대전체를 면진화한 경우보다 증가하는 경향을 나타내었으며, 렌즈의 면진화로 인한 층전단력의 감소가 미소함으로 이중면진의 적용으로 인한 실효성은 그 효과가 크지 않은 것으로 나타났다.