Abstract

In this study, seismic isolation technology to the lighthouse structure is suggested and isolation effects on response reduction are studied for three types of isolation models with the proposed seismic isolation technology. A seismic isolation system is installed on the base of the lighthouse structure in model 1, on the base of the lighthouse lens in model 2, and on the base of both of them in model 3. The dynamic time history analysis verifies that in case of model 1, the earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. Also, the inter-story drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. as a results, model 1 is very effective to mitigate the influence of earthquake on structures. In model 2, isolation effects are valid but special care should be taken to failure of the non-isolated lighthouse sub-structure. In model 3, isolation effects are also valid but the effects are small. model 3 is less effective than model 1.

본 연구에서는 등대 구조물을 대상으로 한 면진기술 적용방안을 제시함으로써 지진에 대해 무방비상태에 놓여 있는 등대구조물의 지진안전도 확보방안을 제시하였다. 또한, 제안된 면진기술 적용방안을 활용하여 내진설계 이전에 지어진 등대를 대상으로 등대전체를 면진하였을 경우와 등대 렌즈만을 면진하였을 경우에 대하여 면진효과를 분석해 보았다. 해석결과, 등대 전체를 면진화하였을 경우 최대응답가속도와 층전단력 측면에서 충분한 면진효과를 얻은 반면, 등대 렌즈만을 면진화한 경우에는 렌즈부의 면진효과는 유효한 것으로 나타났으나 등대 자체의 안전이 확보되지 못한 상황에서는 등대의 파괴가 선행될 가능성이 있음에 주의할 필요가 있는 것으로 나타났다. 또한 등대전체와 렌즈를 동시에 면진화한 경우 비 면진구조 대비 유효한 면진효과는 나타내었지만, 최대응답가속도가 등대전체를 면진화한 경우보다 증가하는 경향을 나타내었으며, 렌즈의 면진화로 인한 층전단력의 감소가 미소함으로 이중면진의 적용으로 인한 실효성은 그 효과가 크지 않은 것으로 나타났다.

Keywords

References

  1. Architectural Institute of Korea, "Building code and commentary", KBC Committee(in korean), 2009.
  2. ASCE/SEI, "Minimum design loads for buildings and other structures", ASCE7-10. 2010, pp.165-178.
  3. Chun, Young Soo, Hur, Moo Won, "Seismic isolation effects according to set up the isolation period in the medium and low-rise framed building", Journal of the Korea Institute for Structural Maintenance and Inspection, vol. 14, No. 6, 2010, pp.1-7. (in Korean)
  4. Japanese Maritime Security Testing Research Center, "Study on the seismic isolation device of a large lighting equipments", Annual report, 1999. (in Japanese)
  5. Japanese Ministry of Land, Infrastructure and Transport, Maritime Security Headquarters, "Aseismic measures of a large coastal lighthouse", Regular press interview report, 2006. (in Japanese)
  6. Japanese Ministry of Land, Infrastructure and Transport, Maritime Security Headquarters, "Installation of the seismic isolation device of a large lighting equipments", Release report, 2005. (in Japanese)
  7. Japanese Ministry of Land, Infrastructure and Transport, Maritime Security Headquarters, "Rebirth of 4 earthquakeresistant lighthouses", Regular press interview report, 2006. (in Japanese)
  8. The Japan Society of Seismic Isolation, "The 9th JSSI Award-Seismic isolation device for the lighthouse lens", 2008.