• 제목/요약/키워드: Facility safety design

검색결과 508건 처리시간 0.028초

FUNCTIONAL VERIFICATION OF A SAFETY CLASS CONTROLLER FOR NPPS USING A UVM REGISTER MODEL

  • Kim, Kyuchull
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.381-386
    • /
    • 2014
  • A highly reliable safety class controller for NPPs (Nuclear Power Plants) is mandatory as even a minor malfunction can lead to disastrous consequences for people, the environment or the facility. In order to enhance the reliability of a safety class digital controller for NPPs, we employed a diversity approach, in which a PLC-type controller and a PLD-type controller are to be operated in parallel. We built and used structured testbenches based on the classes supported by UVM for functional verification of the PLD-type controller designed for NPPs. We incorporated a UVM register model into the testbenches in order to increase the controllability and the observability of the DUT(Device Under Test). With the increased testability, we could easily verify the datapaths between I/O ports and the register sets of the DUT, otherwise we had to perform black box tests for the datapaths, which is very cumbersome and time consuming. We were also able to perform constrained random verification very easily and systematically. From the study, we confirmed the various advantages of using the UVM register model in verification such as scalability, reusability and interoperability, and set some design guidelines for verification of the NPP controllers.

Experimental Study on Calculation of Critical Velocity in Accordance with Gradient of a Road Tunnel at Fire (도로터널 화재시 경사도에 따른 임계풍속산정에 관한 실험적 연구)

  • Kim, Jong-Yoon;Seo, Tae-Beom;Rie, Dong-Ho;Lim, Kyung-Bum;Yoo, Ji-Oh
    • Journal of the Korean Society of Safety
    • /
    • 제21권5호
    • /
    • pp.1-5
    • /
    • 2006
  • This study provides a basic data necessary to design a facility of smoke management after calculating the critical velocity of the gradient scale model tunnel and reviewing its adequacy to establish an optimum disaster prevention system for a road tunnel at fire. The experiment is carried out by using Froude scaling to a scale model which is about 1/29 as big as the real tunnel, and its critical velocity calculation is calculated to the 0-2% gradient of the tunnel. The result shows that the higher the gradient is, the stronger the critical velocity, but that it doesn't affect the critical velocity so much when the gradient is less 2%. In addition, this result is studied in comparison with the results done by other researchers to review the adequacy of the critical velocity.

Performance Tests of a High Capacity Buffer Coupling System using a Hydraulic Device (유압 장치를 이용한 철도 연결기용 고용량 충격완충기의 성능시험)

  • Kim, Namwook;Park, Yeong-il
    • Journal of the Korean Society of Safety
    • /
    • 제31권1호
    • /
    • pp.33-40
    • /
    • 2016
  • Coupling systems under train's collision should take the impact by absorbing the impact energy caused from the collision, so the systems are very important parts for the safety of the trains. However, it is not easy to evaluate the performance of the system because it requires a huge testing facility, which is able to control the impact and to handle many safety issues. In this paper, test results are provided, which are obtained from collision tests of a single train having a coupling system in the front, and the results are analyzed in order to understand the characteristics and the dynamic behaviors of energy absorbing materials in the coupling system, such as a hydraulic buffer, and two rubber buffers. The results show that the force of each component could be empirically described by the compression displacement and velocity. The analyzed results will be applied to simulation models, and advanced studies wouuld be available if the simulation models are well validated with the test results.

Risk Assessment of Tube Trailer Leaks at Hydrogen Charging Station (수소충전소 튜브트레일러 누출에 따른 위험성평가)

  • Park, Woo-Il;Yoon, Jin-Hee;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • 제25권4호
    • /
    • pp.57-62
    • /
    • 2021
  • In this study, risk assessment was conducted in case of leakage of storage facilities (tube trailer) using the HyKoRAM program developed through international joint research. The high-pressure gas facilities in the hydrogen filling station are divided into four main categories: storage facilities (tube trailers), processing facilities (compressors), compressed gas facilities, and filling facilities (dispensers). Among them, the design specifications of the tube trailer, which is a storage facility, and the surrounding environmental conditions were reflected to construct an accident scenario with previously occurring accidents and potential accidents. Through this, we identify the risks of storage facilities at hydrogen refueling stations and suggest measures to improve the safety of hydrogen charging stations.

Analysis of Safety by Expansion of Hydrogen Charging Station Facilities (수소충전소 설비 증설에 따른 안전성 해석)

  • Park, Woo-Il;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • 제24권6호
    • /
    • pp.83-90
    • /
    • 2020
  • This study conducted a risk assessment using the HyKoRAM program created by international joint research. Risk assessment was conducted based on accident scenarios and worst-case scenarios that could occur in the facility, reflecting design specifications of major facilities and components such as compressors, storage tanks, and hydrogen pipes in the hydrogen charging station, and environmental conditions around the demonstration complex. By identifying potential risks of hydrogen charging stations, we are going to derive the worst leakage, fire, explosion, and accident scenarios that can occur in hydrogen storage tanks, treatment facilities, storage facilities, and analyze the possibility of accidents and the effects of damage on human bodies and surrounding facilities to review safety.

Establishment of Condition Assessment Criteria in Agricultural Reservoirs by AHP (AHP 기법에 의한 농업용 저수지의 상태평가 기준 설정)

  • Shim, Jae-Woong;Lee, Young-Hak;Lee, Dal-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제64권5호
    • /
    • pp.17-26
    • /
    • 2022
  • In this study, in order to establish the criteria for evaluation of importance by the type of facility specialized for agricultural reservoirs, an expert group consisting of a total of 167 members who were in management, or specialized in the fields of design, research, and diagnosis were organized, and the importance for facilities was set with application of the AHP technique. The importance of dam body, spillway, and intake structure composing a reservoir were set at 59%, 24%, and 17%, and the importance of dam crest, upstream slope, and downstream slope constituting a dam body was set at 32%, 31%, and 37%, respectively. In addition, the importance of approach channel, regulated channel, chute channel, and stilling basin consisting a spillway was set at 15%, 44%, 26%, and 15%, and the importance of inclined conduit and outlet conduit consisting an intake structure was set at 35% and 65%, respectively. The safety grade of the reservoirs evaluated by applying the newly presented importance values in this study showed the rearrangement of the grades with a change of 11% compared to the previous grades. In this way, the newly established criteria are expected to be utilized as basic data with strategic importance in reservoir safety management and disaster prevention as well as the operation of systems in the future.

Multi-Objective Optimization Study of Blast Wall Installation for Mitigation of Damage to Hydrogen Handling Facility (수소 취급시설 피해 저감을 위한 방호벽 설치 다목적 최적화 연구)

  • Se Hyeon Oh;Seung Hyo An;Eun Hee Kim;Byung Chol Ma
    • Journal of the Korean Society of Safety
    • /
    • 제38권6호
    • /
    • pp.9-15
    • /
    • 2023
  • Hydrogen is gaining attention as a sustainable and renewable energy source, potentially replacing fossil fuels. Its high diffusivity, wide flammable range, and low ignition energy make it prone to ignition even with minimal friction, potentially leading to fire and explosion risks. Workplaces manage ignition risks by classifying areas with explosive atmospheres. However, the effective installation of a blast wall can significantly limit the spread of hydrogen, thereby enhancing workplace safety. To optimize the wall installation of this barrier, we employed the response surface methodology (RSM), considering variables such as wall distance, height, and width. We performed 17 simulations using the Box-Behnken design, conducted using FLACS software. This process yielded two objective functions: explosion likelihood near the barrier and explosion overpressure affecting the blast wall. We successfully achieved the optimal solution using multi-objective optimization for these two functions. We validated the optimal solution through verification simulations to ensure reliability, maintaining a margin of error of 5%. We anticipated that this method would efficiently determine the most effective installation of a blast wall while enhancing workplace safety.

The Proposition of the Checklist and the Case Study of Art Education Environment for Usability and Safety - Focusing on Domestic and International Public Elementary Schools - (사용성과 안전성을 고려한 초등학교 미술교육환경 체크리스트 제안 및 사례연구 - 국내외 공립 초등학교 중심으로 -)

  • Lee, Na Young;Paik, Jin Kyung
    • Korea Science and Art Forum
    • /
    • 제16권
    • /
    • pp.299-310
    • /
    • 2014
  • The purpose of this research propose the improvement of the visual arts educational environment according to the previous studies that is visual arts education have effect on the students' creativity and their Psychological Aspects. In addition, This study provide the preceding material in terms of the future quality of the environment and curriculum for public schools and indicate the advantages and disadvantages of each design space as examining what is needed aspect of the art connectivity. Research method is to investigate the domestic and International public school's visual arts education environment aspects of the facility and space status for safety and activity. As well, method is that it will find out how the program is being conducted in any part of the local culture. Art Education is not the non-intrusive training, but the series of processes going to work together and solve problems through participation of the creative experience based on the art motif. Therefore, it will be a well-supported guideline to establish the art educational environment.

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

Radiation Shielding Analysis for the X-ray Facility (X-선 발생장치 시설의 방사선 차폐 해석)

  • Kwon, Seog-Guen;Choi, Ho-Sin;Moon, Philip-S.;Yook, Jong-Chul
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.34-39
    • /
    • 1987
  • Radiation shielding analysis for a 6MeV X-ray facility was carried out. The primary and leakage radiation for the facility can be evaluated based on the methodology in NCRP No. 49 and 51. The present study deals with radiation scattering analysis for the outside and inside door of the facility based on the albedo concept. The calculated dose rates were compared with the results of MORSE-CG code calculation and the measured data, resulting in a good agreement, even though there existed some deviation for the inside door. These results can be utilized to the radiation shielding design of the medical and industrial X and gamma ray facilities, and to the safety evaluation of these facilities.

  • PDF