• Title/Summary/Keyword: Facility Inspection

Search Result 341, Processing Time 0.028 seconds

Investigating Factors Contributing to Inadequate Facility Safety Inspections and Diagnosis Services: A Machine Learning Approach (머신러닝 기반 시설물 안전 점검·진단용역 부실 판정 요인에 대한 연구)

  • Junyong Park;Chie Hoon Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.897-908
    • /
    • 2024
  • Evaluating the adequacy of facility safety inspection and diagnosis services performed by private enterprises is a time-consuming and administratively complex process. This study aims to analyze the determinants that could influence the rating of these safety inspection and diagnosis services using data analytics approach. Through a comparative analysis of several machine learning algorithms suitable for multi-class classification, we selected the model with the best performance (Random Forest) and identified the main determinants using the permutation importance technique. Among the variables examined, "contract value," "days of service performed" and "adherence to fair market value" were found to be strongly correlated with the rating assessments. Furthermore, we discovered that the skills and expertise of service performing personnel significantly impacted the rating. The results of this study can contribute to the enhancement of the current post-evaluation administrative processes and offer valuable insights into rating assessments by incorporating previously unexplored variables pertaining to both service providers and the services itself.

Analysis of Earthquake Countermeasure for Electrical Facility Building on Domestic and Foreign (국내외 건축물에 시설되는 수변전설비 지진 대책에 관한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.150-156
    • /
    • 2008
  • Recently life and properties damage at Japan and China by generating earthquake. For establishing measure for earthquake in domestic, earthquake disaster measure law was enacted on March, 2008 from a natural disaster of earthquake and present the detail part and enforce the measures. This paper analyzes domestic site and problems of electrical facility earthquake measures at transformer vault which the power supply the emergence situation at generating earthquake. Also we present the domestic seismic design and construction direction from research and analysis related law and regulation for the seismic design and construction in domestic and foreign for electrical facility. Afterward we will need to study reliability inspection for electrical facility seismic design method and construction at buildings transformer vault.

A Study in the Selection Factors of Facility Management(FM) Enterprises Using AHP Analysis (AHP 분석을 활용한 Facility Management(FM) 기업의 선택 요인에 관한 연구)

  • Han, Sanghun;Kim, Seungchul;Park, Sohyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.3
    • /
    • pp.193-205
    • /
    • 2019
  • Looking at recent safety accidents in buildings, most of them due to lack of FM expertise, and this is due to human resources. In each all industry areas, some companies are competitive, representational, and leading in the market through long-term expertise and research in their respective fields. In the field of FM industry, some companies offer core-competencies in internal and external innovative building management through competition with others. However, old custom and old management form still exist in the FM field. However, an old custom and old management system still exist in the FM field; it forces cost-cutting and caused by carelessness in technical development competitiveness and safety measures. The government control by safety inspection and facility inspection through legislation of building management, but the management is still weak as a side of in the facility management section due to inspect sth as a mere formality and submit a paper report. These facts exist different kind of usage of the building have a three-party encounter between a building owner, user, and FM enterprises. In this research identify survey, especially building owner (manager)'s choice perception priority for optional factors to choose FM enterprises. Based on this, FM enterprises will be forced to seek a new dimension for better building management. In this light, the purpose of the research is to shape changes in the FM market culture safely and providing better service in building management and understanding building owner's insight through this research's information.

Derivation of Critical Success Factors for Operation Management of Educational Facility Maintenance Management Program (교육시설 유지관리 프로그램 운영관리를 위한 핵심성공요인 도출)

  • Lee, Mi-Young;Park, Sang-Hun;Yoon, Sun-Jae;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.51-52
    • /
    • 2021
  • The maintenance of educational facilities is divided into inspection and management of facility managers residing in the school and Educational Environment Improvement Projects(EEIP) to carry out maintenance work. Educational support organizations collect maintenance requests through facility inspections by school-specific facility managers, and carry out numerous maintenance projects during the year. The EEIP has the characteristic of Program Management with interrelationships between projects, not multiple projects management. The purpose of the EEIP is to eliminate the inconvenience of school facility users and increase their satisfaction, and achieving the goal is judged to be successful. Despite the importance of management and performance measurement utilizing Critical Success Factor(CSF) for the operation of successful educational facility maintenance management programs, the system for achieving the goals is insufficient. This study derives CSFs for each stage of the EEIP for the success of the EEIP. The CSFs for each stage of the EEIP is expected to serve as a basis for evaluation of educational facility maintenance management programs and can be used as an evaluation index in the future.

  • PDF

Study on the Estimation Method of Safely Index for Community Disaster (지역안전도 진단 방법 개선에 관한 연구)

  • Jang, Dae-Won;Jeong, Sang-Man;Park, Moo-Jong;Kim, Hung-Soo;Seoh, Byung-Ha
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.119-127
    • /
    • 2007
  • We reconstructed the community disaster risk and patterns of damage magnitude using 'Annual Report of National Disaster Data'. And we developed the inspection index for damage reduction capacity of each facility or each damage prevention measure. The inspection indices include climatic and hydrological vulnerabilities, and disaster probability components. Also we considered all indices and components for DB construction on the GIS system. Then we constructed 'Inspection for Safety Degree of Community System(ISDCS)' according to the facility's criteria from the combination of damage reduction capacity of facility and damage magnitude. The safety index has designed a system that encourages communities to carry out a list of activities in the raw from natural disaster. The activities ultimately saves lives, reduce property damage, and protect disaster facilities. Damage patterns were also analyzed according to damage type using pattern analysis and GIS.

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

A Research on the Determining Model of the Optimizing Maintenance Interval in TBM for the Preventive Maintenance of Facilities (설비예방보전을 위한 TBM의 최적보전주기 설정모델 연구)

  • Kwon Oh-Woon;Lee Hong-Chul
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.105-117
    • /
    • 2003
  • The purpose of this research aimed at performing the easy design. and also the easy on-the-job application or the maintenance interval determination methodology by presenting the determining model or the optimizing maintenance interval in TBM for the preventive maintenance or facility TBM(time-based maintenance) as the preventive maintenance requires the adequate determination or the maintenance interval. The maintenance interval or TBM shall be applied differently for the each interval such as He patrol inspection, maintenance, overhaul inspection. exchange. And it is based on the composition level of equipment. The already informed theories or interval determination methodology for the patrol inspection. repair. and overhaul inspection are difficult for adopting because or the several restriction problems in applying the maintenance schemes as the theory So, the model for determining the optimizing exchange interval or part, maintenance interval of auxiliary machine, unit equipment etc. was presented to apply in the maintenance easily and appropriately.

  • PDF

Development of Risk-Based Inspection(RBI) Technology for LNG Plant Based on API RP581 Code (API RP 581 Code를 기반으로한 LNG 플랜트의 Risk-Based Inspection(RBI) 기술 개발)

  • Choi, Song-Chun;Choi, Jae-Boong;Hawang, In-Ju
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.179-183
    • /
    • 2012
  • As one of promising solutions to overcome high oil price and energy crisis, the construction market of high value-added LNG plants is spotlighted world widely. The purpose of this study is to introduce LNG-RBI system to develop risk assessment technology with RAM(Reliability, Availability, Maintainability) modules against overseas monopolization. After analyzing relevant specific features and their technical levels, risk assessment program, non-destructive reliability evaluation strategy and safety criteria unification class are derived as core technologies. These IT-based convergence technologies can be used for enhancement of LNG plant efficiency, in which the modular parts are related to a system with artificial optimized algorithms as well as diverse databases of facility inspection and diagnosis fields.

The Inspection Procedure and Method of GIS to Guarantee the Safety of Power Facility (전력설비 안전성 확보를 위한 GIS(가스절연개폐장치) 검사수행 절차 및 방법)

  • Park, Jun-Sung;Hwang, Kwang-Soo;Kim, Jin-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.361-364
    • /
    • 2015
  • 본 논문은 전기사업법 제61조의 공사계획인가 및 신고대상인 차단기에 대하여 동법 제63조에 의거해 실시하는 사용전검사의 항목 및 검사수행 방법에 대하여 서술하였다. 차단기는 전력계통을 이상전압에서 보호하기 위한 밀폐형 개폐장치로서 전기사업용 전기설비인 변전소에 설치되는 차단기는 대부분 GIS(Gas Insulated Switchgear)화 되고 있는 실정이다. GIS는 정상전류의 차단, 설비사고의 억제 및 파급사고 확산방지에 중추적인 역할을 수행하고 있기 때문에 그 중요성은 더욱 더 높아지고 있다고 볼 수 있다. 이에 핵심 전력설비인 GIS의 사용전 검사항목 및 검사수행 방법을 고찰함으로써 안정적인 전력공급과 전력계통의 신뢰도 제고에 기여하고자 한다.

  • PDF

Development of Underwater ROV for Crack Inspection of River Facilities (하천 시설물 균열 검사를 위한 수중 ROV 개발)

  • Seong, Ho-Hwan;Lee, Jang-Myung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.4
    • /
    • pp.129-136
    • /
    • 2021
  • River facilities and port structures require a regular inspection and diagnosis due to obsolescence. Currently, most river facilities are undergoing indirect inspection and diagnosis by divers. The underwater inspections are not feasible due to safety issues of divers and restrictions on working hours and environment. To overcome these issues, it is intended to conduct inspections of river facilities using underwater drones. In this research, an underwater ROV (Remote Operated Vehicle) has been developed, which is a kind of drone with propellers. As a key device of this research, an injection device has been attached to the underwater drone to conduct an operation test, a stable operation test of an underwater drone, and a test of attached sensors. The river facility inspection can be carried out optimally using the hovering control of the drone and injection systems. With the developed ROV system, hovering test and injection test have been performed to verify the feasibility of this development.