• Title/Summary/Keyword: Fabricating Temperature

Search Result 202, Processing Time 0.027 seconds

Co-Firing of Low- and Middle- Permittivity Dielectric Tapes of Fabricating Low-Temperature Co-Fired Ceramics (LTCC용 저/중유전율 유전체 후막의 동시소성)

  • Choi Young-Jin;Park Jeong-Hyun;Ko Won-Jun;Park Jae-Hwan;Nahm Sahn;Park Jae-Gwan
    • Korean Journal of Materials Research
    • /
    • v.14 no.10
    • /
    • pp.731-736
    • /
    • 2004
  • Herein, we report on the co-firing of a low-K wiring substrate and a middle-K functional substrate in LTCC. Firstly, we researched the sintering behavior and dielectric properties of the low-k wiring substrate comprised by alumina and glass frit with ${\varepsilon}_r$, of $\sim7$ and the middle-k functional substrate comprised by $Ba_{5}Nb_{4}O_{15}$ and glass frit with ${\varepsilon}_r$, of $20\sim30$. The warpage and delamination between the hetero layers of the low-K and the middle-K composition were also studied. In particular, physical matching of the hetero layers could be possible by adjusting of the sintering properties of the composition. We observed that an introduction of the glass frit to the low- and middle-K substrate gives rise to a minimization of an effect given by separation of the hetero layers, and modification of the fraction of the glass frit accompanied by a variation of the composition could control the sintering behavior and its beginning temperature. In the case of co-firing of the L03 as the low-K wiring substrate composition and the M03 as the middle-K functional substrate composition at $875^{\circ}C$, we could fabricate a desirable structure of hetero layers without any kinds of structural defects such as separation, warpage, delamination, pore trap, etc. We suppose that the co-firing techniques described in this study would provide a helpful method to fabricate a LTCC multi-functional for the next generation.

Development and Characterization of Horse Bone-derived Natural Calcium Phosphate Powders

  • Jang, Kyoung-Je;Cho, Woo Jae;Seonwoo, Hoon;Kim, Jangho;Lim, Ki Taek;Chung, Pill-Hoon;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.122-133
    • /
    • 2014
  • Purpose: This study was to develop an effective process for fabricating biocompatible calcium phosphate powders (CPPs) using horse bones, and to investigate the characteristics of them. Methods: The characteristics of horse bone powders (HBPs) were investigated according to the different osseous tissue types (compact bone and cancellous bone), bone types (spine and tibia), pretreatment methods (cold water, $H_2O_2$, and hot water), sintering time (4, 8 and 12h), and sintering temperature (600, 900, 1100 and $1300^{\circ}C$). In addition, the grinding methods were compared based on the wet grinding (ball mill) and dry grinding (blade grinder) method to make it as powders. Finally, their cytotoxicity and cell viability were checked. Results: Regardless of the types of osseous tissues and bones, HBPs were well fabricated as biocompatible CPPs. It was also found that the pretreatment methods did not influence on the resultants, showing well-fabricated HBPs. Considering the processing time, the hot water method was the most suitable compared to other pretreatment methods. Further, 12h-sintering time was sufficient to remove residual organic compounds. The sintering temperatures greatly affected the properties of bone powders fabricated. The x-ray diffraction (XRD) peak of horse bone sintered at $600^{\circ}C$ was most closed to that of hydroxyapatite (HA). Our bioactivity study demonstrated that the HBPs fabricated by sintering horse bones at $1300^{\circ}C$ showed the best performance in terms of cell viability whereas the HBPs $1100^{\circ}C$ showed the cytotoxicity. Conclusions: Using various types of horse bone tissues, biocompatible CPPs were successfully developed. We conclude that the HBPs may have a great potential as biomaterials for various biological applications including bone tissue engineering.

Effect of milling and sintering process on integrity of zirconia prosthesis: a literature review (밀링과 소결과정이 지르코니아 보철물의 완성도에 미치는 영향에 관한 문헌고찰)

  • Lee, Kiun;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.127-137
    • /
    • 2022
  • Zirconia is fabricated through various processes. Each element in fabricating process can affect the physical properties of the definitive prosthesis. In particular, both the milling process and the sintering process can affect the final integrity of the zirconia prosthesis. Most of the milling machines adopt the ultra-precision 5-axis machining method, and the results vary depending on which milling method was used and how the milling equipment was managed. Milling blocks are selected according to cutting efficiency and aesthetic reproducibility. The sintering method can affect the grain growth and optical properties, and an accurate evaluation can be made only with additional research on the recent speed sintering procedure. Not only the sintering temperature but also the temperature holding time can affect the quality of definitive prosthesis.

Phase Behavior of Poly(methylmethacrylate) (PMMA) in Varions Solvents at High Pressure (고압상태의 다양한 용매 내에서 Poly(methylmethacrylate) (PMMA)의 상거동)

  • Kim, Je-Il;Yoo, Ki-Pung;Lim, Jong-Sung
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.28-33
    • /
    • 2007
  • We measured cloud points of Poly(methylmethacrylate) (PMMA) in various solvents using the high-pressure variable volume view cell apparatus. The solvents used for dissolving PMMA were chlorodifluoromethane (HCFC-22), dimethylether (DME), 1,1,1-trifluoroethane (HFC-143a), 1,1-difluoroethane (HFC-152a) and 1,1,1,2-tetrafluoroethane (HFC-134a), and the effect of $CO_2$ concentration on the phase behavior of $PMMA+HCFC-22+CO_2$ system and $PMMA+DME+CO_2$ system was observed. PMMA was dissolved well in HCFC-22 from about 340 K, 5MPa and in DME from about 300 K, 28MPa. However, PMMA was not dissolved at all up to 423.15 K, 160MPa in the other fluorine compound such as HFC-l43a, HFC-152a and HFC-134a. PMMA+HCFC-22, $PMMA+HCFC-22+CO_2$ and PMMA+DME systems exhibit the lower critical solution temperature (LCST) behavior, however, $PMMA+DME+CO_2$ system exhibits the upper critical solution temperature (UCST) behavior. In the $CO_2$ mixture, the cloud point pressure of PMMA was increased dramatically proportional to the amount of $CO_2$ added, and from this result, it was known that $CO_2$ could be used as an antisolvent for fabricating PMMA nano-particles. And the cloud point of PMMA could be controlled by changing the concentration of $CO_2$.

  • PDF

Fabrication of a High-performance Oscillator with a Tunable High-Q HTS $YBa_2Cu_3O_{7-\delta}$ Resonator (High-Q $Yba_2Cu_3O_{7-\delta}$ 고온초전도체 공진기를 이용한 주파수 튜닝이 가능한 고성능 발진기 제작)

  • Yang Woo Il;Lee Jae Hun;Hur Jung;Lee Sang Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.7 s.337
    • /
    • pp.63-70
    • /
    • 2005
  • We investigated the phase noise of an oscillator with a extremely high-Q resonator used as the resonant element. A TE$_{011}$ mode rutile-loaded resonator with high-temperature superconductive (HTS) $YBa_2Cu_3O_{7-\delta}$(YBCO) films used as the endplates is prepared for this purpose. At 23.5 K, the unloaded Q and the loaded Q are 863000 and 180000, respectively. The phase noise of -104.8 dBc/Hz at 1 KHz offset was observed for the oscillator having a resonator with $Q_{L}$ =180000 at the $TE_{01\delta$ mode resonant frequency of 8.545 GHz at 23.5 K Such oscillators with very low phase noise are expected to be used for building up communication systems capable of efficient use of the frequency band and high-speed data transmission as well as for Doppler radars. Frequency tuning could be realized for the resonator by using a piezoactuator Applicability of the tunable rutile resonator for fabricating tunable oscillators of high performances is discussed.

On the Statistical Properties of the Parameters B and q in Creep Crack Growth Law, da/dt=B(C*)q, in the Case of Mod. 9Cr-1Mo Steel (Mod. 9Cr-1Mo강의 크리프 균열 성장 법칙의 파라메터 B와 q의 통계적 성질에 관한 연구)

  • Kim, Seon-Jin;Park, Jae-Young;Kim, Woo-Gon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.251-257
    • /
    • 2011
  • This paper deals with the statistical properties of parameters B and q in the creep crack growth rate (CCGR) law, da/dt=B$(C^*)^q$, in Mod. 9Cr-1Mo (ASME Gr.91) steel which is considered a candidate materials for fabricating next generation nuclear reactors. The CCGR data were obtained by creep crack growth (CCG) tests performed on 1/2-inch compact tension (CT) specimens under an applied load of 5000N at a temperature of $600^{\circ}C$. The CCG behavior was analyzed statistically using the empirical equation between CCGR, da/dt and the creep fracture mechanics parameter, $C^*$. The B and q values were determined for each specimen by the least-squares fitting method. The probability distribution functions for B and q were investigated using normal, log-normal, and Weibull distributions. As far as this study is considered, it can be appeared that B and q followed the log-normal and Weibull distributions. Moreover, a strong positive linear correlation was found between B and q.

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

마이크로파 응용을 위한 고온초전도 필터 서브-시스템

  • 강광용;김현탁;곽민환
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.20-40
    • /
    • 2003
  • Since unloaded Q-value of a high-temperature superconductor(HTS) filter is very high, a bandpass filter(BPF) and a lowpass filter(LPF) with an increase of pole numbers can be fabricated without an increase of an insertion loss(IL) ; recently a 70-pole BPF is developed in USA. They have an abrupt skirt property and an excellent attenuation level for out-of band. Moreover, they can be miniaturized when lumped element resonators or the slow-wave characteristic are used. Technology of fabricating a HTS epitaxial film as well as a film of a 4 inch area also makes the planar type filter with a various structure and an enhanced power handling capability possible. Recently, the HTS filter subsystems composed of a planar-type HTS filters, a GaAs-based LNA and a mini-cryocooler are developed. The extended receiver front- end subsystems for mobile radio communications decrease the noise-figure level of the communication system and the frequency interference interacted adjacent bands, and increase the efficiency of frequency and the capacity of communication system. In this paper, theory for developing the HTS filter, its kinds, its design rules, its characteristics are reviewed. The feature of the research and market trends related to the HTS filter systems for the receiver front-end subsystem of mobile base station are surveyed.

Formation Mechanism of Pores in Ni-P Coated Carbon Fiber Prepared by Electroless Plating Upon Annealing (무전해 니켈-인 도금법을 이용하여 도금된 탄소 섬유의 열처리 과정에서 나타나는 다공성 구조 생성 메커니즘 분석)

  • Ham, Seung Woo;Sim, Jong Ki;Kim, Young Dok
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.438-442
    • /
    • 2013
  • In the present work, electroless plating was used for coating thin films consisting mainly of Ni and P on carbon fiber. Structural changes appeared upon the post-annealing at various temperatures of the Ni-P film on carbon fiber was studied using various analysis methods. Scanning, a flat surface structure of Ni-P film on carbon fiber was found after electroless plating of Ni-P film on carbon fiber without post-annealing, whereas annealing at $350^{\circ}C$ resulted the formation of porous structures. With increasing the annealing temperature to $650^{\circ}C$ with an interval of $50^{\circ}C$, the pore size increased, but the density decreased. X-ray diffraction (XRD) showed the existence of metallic Ni, and Ni-P compounds before post-annealing, whereas the post-annealing resulted in the appearance of NiO peaks, and the decrease in the intensity of the peak of metallic Ni. Using X-ray photoelectron spectroscopy (XPS), phosphorous oxides were detected on the surface upon annealing at $650^{\circ}C$, and $700^{\circ}C$, which can be attributed to the phosphorous compounds originally existing in the deeper layers of the Ni films, which undergo sublimation and escape from the film upon annealing. Escape of phosphorous species from the bulk of Ni-P film upon annealing could leave a porous structure in the Ni films. Porous materials can be of potential applications in diverse fields due to their interesting physical properties such as high surface area, and methods for fabricating porous Ni films introduced here could be easily applied to a large-scale production, and therefore applicable in diverse fields such as environmental filters.

Fabrication of PCL Scaffolds According to Various Pore Patterns Using Polymer Deposition System and Design of Experiments (폴리머 적층 시스템과 실험계획법을 이용한 다양한 공극 패턴에 따른 PCL 인공지지체의 제작 연구)

  • Sa, Min-Woo;Choi, Sun-Woong;Lee, Jae-Wook;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.645-653
    • /
    • 2017
  • In bone tissue engineering, polycaprolactone (PCL) is one of the most widely used biomaterials in the manufacturing of scaffolds as a synthetic polymer having biodegradability and biocompatibility. The strut width in the fabrication of scaffolds is an important part of tissue regeneration in in-vitro and in-vivo experiments, because it affects not only the pore size but also the porosity. In this study, we used polymer deposition system (PDS) and design of experiments (DOE) to explore the optimal process conditions to achieve a systematic and efficient scaffold manufacturing process, using temperature, pressure, scan velocity, and nozzle tip height as the parameters for the experiments. The aim of this research was to fabricate a 3D PCL scaffold having a uniform strut width of $150{\mu}m$ using DOE; it was proved that the strut width was constant in all the experimental groups by fabricating the PCL scaffolds according to various pore patterns as well as one pore pattern.