• Title/Summary/Keyword: Fabricated report

Search Result 484, Processing Time 0.037 seconds

Novel Flexible Supercapacitors Fabricated by Simple Integration of Electrodes, Binders, and Electrolytes into Glass Fibre Separators

  • Yoo, Joung Eun;Bae, Joonho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.4
    • /
    • pp.237-244
    • /
    • 2014
  • We report novel and simple structure of supercapacitors fabricated by using flexible glass fibre separators as templates. This method does not require separate electrodes, binders and high pressure/temperature to build the supercapacitor unit cells as required by the conventional technology. The supercapacitors were fabricated by drop-casting solution mixtures of carbonaceous active materials/gel electrolytes onto two sides of glass fibre separators. Two carbonaceous materials (nanoscaled activated carbons, multi-walled carbon nanotubes) were investigated as electrode materials. The electrochemical measurements reveal that the separatorbased supercapacitors using ACs successfully demonstrated significant mass specific capacitance ($22.3F\;g^{-1}$) and energy density ($9.7Wh\;kg^{-1}$), indicating this method can be useful in fabricating flexible, wearable and stretchable energy storage devices in more straightforward and cost-effective way than current technology.

레이저 봉과 Disk Amplifier 제작용 광학 공작 기계 설계와 제작

  • 김영기
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.26-31
    • /
    • 1989
  • Optical working machines are developed. the machines are to be used in the preparation of Nd-phosphate glass amplifier rod and elliptical disk amplifier plate of the high power Nd-YLF-phosphate glass laser amplifier system. In this report, the working principles of the machines are presented, and several results are shown by photographes, design drawing and the disks actually fabricated by using the machines.

  • PDF

Precise Replica Technology Study for Fine Optical Waveguide Device (미세 광소자용 도파로 정밀 복제기술 연구)

  • Oh S.H.;Kim C.S.;Jeong M.Y.;Boo J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1493-1496
    • /
    • 2005
  • In this paper, we describe a simple, precise and low cost method of fabricating PDMS stamp for UV embossing. It is important to improve the replication quality of stamp because the accuracy of fabricated structure is related to that of the stamp in UV embossing. The PDMS stamp has been fabricated by the replica molding technology with ultrasonic vibration to eliminate micro-air bubbles during the fabrication process of PDMS stamp. Also, this fabrication to use ultrasonic vibration promotes PDMS solution to fill into micro channel and edge parts. We report the fabrication of an optical core using UV embossing with fabricated PDMS stamp. This fabricated core is $7\;\mu{m}\;at\;depth,\;6\;\mu{m}\;at\;width.\;This\;measured\;value\;has\;the\;difference\;below\;1\;\mu{m}$compared to the original stamp. The surface roughness of core is about 14 nm root mean square. This is satisfactory value to use low-loss optical waveguide. Our successful demonstration of precise replica technology presents an alternative approach for the stamp of UV embossing.

  • PDF

Fabrication of a Optical Planar Waveguide Lens by Ti-Indiffused Proton-Exchange (Ti 내부확산/양자교환(TIPE)방식에 의한 평면 광도파로 렌즈의 제작)

  • 정석문;최성식;윤태훈;김재창
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.4
    • /
    • pp.371-378
    • /
    • 1992
  • In this paper we report the fabrication of a planar optical wavehuide lens on a Y-cut LiNbO3 substrate by Ti_indiffusion and Ti-indiffused proton-exchange(TIPE). LiNbo3 planar waveguides are fabricated and refractive indices of the waveguides are fabricated and refractive indices of the waveguides are measured. Based on the measured indices, palanr waveguide lenses are designed and fabricated. The measured focal point and spot size of the fabricated lens are in good agreement with those of the designed lens.

  • PDF

Cr-Co removable partial denture treatment fabricated by selective laser melting: a case report (Selective Laser Melting을 이용한 코발트-크롬 가철성 국소의치의 수복 증례)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.39-47
    • /
    • 2021
  • Compared to conventional method, if metal framework of removable partial denture is fabricated by selective laser melting, various laboratory works are omitted, saving time and simplifying the process. In addition, metal framework with homogeneous density can be obtained, expecting excellent mechanical properties, especially resistance to fatigue fracture. In these cases, impression were taken using conventional methods in partial edentulous patients, master casts were fabricated and scanned to obtain digital data. After designing the metal frameworks on the scanned data, removable partial dentures were fabricated using selective laser melting methods. Through these procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

CAD/CAM fabricated complete denture using 3D face scan: A case report (3D face scan을 이용한 CAD/CAM 제작 의치 증례)

  • Eom, Dae-Young;Leesungbok, Richard;Lee, Suk-Won;Park, Su-Jung;Ahn, Su-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.436-443
    • /
    • 2017
  • In the past, computer-aided design / computer-aided manufacturing (CAD/CAM) technology was the closed system that users had to use the components of only one manufacturer. At present, it has changed to the open system with the flexibility to select and use the components of various manufacturers' components according to their needs. Despite the development of dental materials and prostheses manufacturing methods, denture manufacturing has followed conventional manufacturing methods for nearly 100 years. However, studies on CAD/CAM fabricated denture have been recently carried out to overcome the disadvantages of conventional denture manufacturing. Some commercialized products using milling or 3D printing have already been applied clinically. This case report confirms the possibility of CAD/CAM dentures using 3D face scan and compared them to conventionally fabricated dentures.

A case report of a surgical guide fabricated via intraoral scanning-based implant planning and wax-based rapid prototyping (구강스캐너를 이용한 임플란트 수술 계획 및 왁스 기반 쾌속조형법으로 제작한 수술용 가이드 증례)

  • Shin, Jong-Hoon;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.244-249
    • /
    • 2015
  • With the recent progress of digital technology, the computer guided surgery utilizing a guide template in the placement of implant has been actively performed, and the method employing the intraoral scanner at the implant prosthesis introduced. Fabrication method of the guide template can be largely classified into design-related rapid prototyping (RP) system and vector milling system, and each of the method has its own weakness in the clinical application despite of excellent accuracy. Thus, in this case study, a working model was fabricated by the wax RP technology using images acquired by CBCT and an intraoral scanner, and the metal bushing was picked up with orthodontic resin cast upon the wax model. Using this method, a surgical guide template was fabricated and used in surgery. From this, we could obtain a satisfactory outcome clinically in the implant placement and the fabrication of the final prostheses and thus report this case herein.

Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption (임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료)

  • Choi, Yu-Sung
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

Comparative evaluation of two sets of complete dentures fabricated by digital and conventional workflow in a single patient: A case report (단일 환자에서 디지털 및 전통적인 워크플로우로 제작한 두 쌍의 총의치를 장착하여 비교평가한 증례 보고)

  • Kim, Sang Hyun;Oh, Kyung Chul;Park, Ji Man;Kim, Jee Hwan;Moon, Hong Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.350-358
    • /
    • 2021
  • Application of digital technology in dental treatments can simplify the treatment process and reduce patient discomfort. In regards of digital complete dentures, several commercial systems are available. However, these systems are not being routinely applied in Korea. In this case report, comparative analyses were performed regarding the two sets of complete dentures fabricated in digital and conventional workflow in a single patient. Complete dentures made with digital workflow were able to form an ideal occlusion because customized teeth were used. Compared to that, there were also limitations such as lower retention of mandibular dentures, so we would like to report this.