• Title/Summary/Keyword: Fabric filter

Search Result 75, Processing Time 0.02 seconds

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

A Study on Performance of Double-Core PBD for Improving Thick Reclaimed Ground (대심도 연약지반 개량을 위한 이중코어 PBD 성능연구)

  • Yang, Jeong-Hun;Hong, Sung-Jin;Lee, Woo-Jin;Choi, Hang-Seok;Kim, Hyung-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.281-292
    • /
    • 2008
  • Prefabricated Board Drains (PBDs) recently become more widely used than conventional sand drains in improving soft ground because the PBD is more time and cost effective. The performance of PBDs is affected by disturbance in the adjacent soil formation during inserting mandrels, the intrusion of fine particles into filter fabric, and necking of the drain by excessive lateral pressure especially occurring in very deep clay formation such as the Busan New Port site. In this study, the PBD with double-core is introduced, which seems to overcome the shortcomings of usual single-core PBDs. An in-situ test program was established in the Busan New Port site, in which a set of the double-core PBDs and the single-core PBDs was installed to compare the efficiency of each of the drains. The discharge capacity of the double-core and the single-core PBDs was compared for various confining pressures in the modified Delft test and the chamber test. A series of CRS consolidation tests was performed in order to obtain profiles of void ratio-effective stress and void ratio-permeability relationships in the Busan New Port site that are used as input date in performing a numerical program ILLICON. The numerically simulated settlements of ground surface in the test site are in good agreement with those of in-situ measurements. In addition, the performance of the double-core and single-core PBDs has been experimentally and numerically compared in this paper.

  • PDF

A Study on Prevention of Fire Accidents by Splash Filling in the Filtration Process of Pharmaceutical Companies (제약회사 여과 공정중 스플래쉬 필링에 의한 화재사고 예방대책에 관한 연구)

  • Kim, Sang Gil;Lee, Dae Joon;Yang, Seung Bok;Rhim, Jong Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.29-34
    • /
    • 2021
  • Flammable substances are often present in the raw materials of pharmaceutical products manufactured by pharmaceutical companies. In this case, an excessive amount of flammable substances is added to make an intermediate, and flammable substances that do not participate in the reaction are removed through filtration and drying steps. In addition, the flammable liquid separated in the filtration process is accumulated in the form of splash filling in the filtrate container. In this case, vapor and mist of flammable liquid are generated, which lowers the lower limit of explosion and minimum ignition energy, and increases the risk of fire and explosion due to complex charging. In this study, by analyzing fire accidents that occurred during the recent filtration process of pharmaceutical companies, it is proposed to prevent static electricity accumulation by measures of nitrogen supply facilities, capacity improvement, conductive filter fabric and so on.

Comparision of Ca- and Na- Based Dry Sorbent in Desulfurization Characteristics (Ca계 및 Na계 흡수제의 건식 탈황 특성 비교)

  • Moon, Seung-Hyun;Hyun, Ju-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • Physico-chemical characteristics of the Ca-based and Na-based dry sorbents were compared using thermo-gravimetric analysis (TGA) and temperature programmed desorption (TPD) methods. The studied characteristics were thermal stability, sulfur dioxide ($SO_2$) absorption capacity and absorption rate at $250^{\circ}C$ which is a typical temperature before a fabric filter, and $SO_2$ absorption capacity at an ambient temperature. Calcium hydroxide ($Ca(OH)_2$) started to decompose into calcium oxide (CaO) at $390^{\circ}C$ and completed at 480~$500^{\circ}C$, showing 76% of an original $Ca(OH)_2$ weight. Sodium bicarbonate ($NaHCO_3$) also converted to sodium carbonate ($Na_2CO_3$) between $95^{\circ}C$ and $190^{\circ}C$, decreasing the weight to 63% of its initial weight. Among four sorbents tested at $250^{\circ}C$, sodium carbonate had the highest capacity, absorbing 0.35 g $SO_2$/g sorbent. Calcium oxide and calcium hydroxide followed that showing 0.156 g and 0.065 g $SO_2$ absorption per absorbent respectively. Ca-based absorbents showed slower rate than sodium carbonate because of initial stagnant step. However, calcium hydroxide caught more $SO_2$ than sodium carbonate at ambient temperature. From this work, it can be concluded that Ca-based absorbent is a proper sorbent for $SO_2$ treatment at low temperature and sodium carbonate, at high temperature.