• 제목/요약/키워드: FVM

검색결과 245건 처리시간 0.023초

LED 패키지에서 에폭시 몰드가 방열특성에 미치는 영향 (Effect of the Epoxy Mold on the Thermal Dissipation Behavior of LED Package)

  • 방영태;문철희
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.1-7
    • /
    • 2012
  • LED package with 4[mm]-height mold was manufactured and the surface temperature was measured directly using both thermocouple and thermal infrared (IR) camera. FVM simulation was conducted to estimate the surface temperature of the same LED package under the same condition, by which the accuracy of the simulation was secured. Then, the effects of the height and thermal conductivity of the mold on the junction temperature of the LED package were investigated by FVM simulation. The results showed that the junction temperature decreased by 10[$^{\circ}C$] when the mold height was 3~5[mm], but the thermal conductivity of the mold didn't affect the junction temperature significantly.

HYDROPLANING ANALYSIS BY FEM AND FVM - EFFECT OF TIRE ROLLING AND TIRE PATTERN ON HYDROPLANING

  • Nakajima, Y.;Seta, E.;Kamegawa, T.;Ogawa, H.
    • International Journal of Automotive Technology
    • /
    • 제1권1호
    • /
    • pp.26-34
    • /
    • 2000
  • The new numerical procedure for hydroplaning has been developed by considering the following three important factors; fluid/structure interaction, tire rolling, and practical tread pattern. The tire was analyzed by FEM with Lagrangian formulation and the fluid is analyzed by FVM with Eulerian formulation. Since the tire and the fluid are modeled separately and their coupling is automatically computed by the coupling element, the fluid/structure interaction of the complex geometry such as the tire with the tread pattern can be analyzed practically. We verified the predictability of the hydroplaning simulation in the different parameters such as the water flow, the velocity dependence of hydroplaning, and the effect of the tread pattern on hydroplaning. In order to predict the streamline in the contact patch, the procedure of the global-local analysis was developed. Since the streamline could be predicted by this technology, we could develop the new pattern in a short period based on the principle; "make the stream line smooth".

  • PDF

FVM과 반무한체 해석을 이용한 표면온도예측에 관한 연구 (A Study for Estimation of the Surface Temperature Rise Using the FVM and Semi-Infinite Solid Analysis)

  • 김태완;이상돈;조용주
    • Tribology and Lubricants
    • /
    • 제18권6호
    • /
    • pp.389-395
    • /
    • 2002
  • The surface temperature at the interface of bodies in a sliding contact is one of the most important factors influencing the behavior of machine components. The calculation of the surface temperature at a sliding contact interface has been an interesting and important subject for tribologist. Temperature analyses were usually performed under the consideration contacted two bodies as semi-infinite. But the analysis was difficulty in being applied to finite body and considering the boundary condition. In this study, contact temperature rise of two finite bodies and surfaces due to frictional heating under the rectangular and the circular sliding contact is calculated. Heat partition factor is calculated using semi-infinite solid analysis and the temperature of the finite bodies is calculated using FVM. It will be shown that Most frictional heat in the fore part of contact region for sliding direction is conducted into body that has a moving heat source and the site of the maximum temperature rise moves to the opposite direction of sliding during sliding.

유한체적법(FVM)의 시뮬레이션을 활용한 LED 벌브의 열 특성 고찰 (Investigation of the Thermal Characteristics of LED Bulb Utilizing Simulation of Finite Volume Method (FVM))

  • 박경민;문철희
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.1-8
    • /
    • 2014
  • Heat dissipation of the high power LED is a critical issue. To estimate the junction temperature of the LED chip is most important in characterizing the heat dissipation, but it is impossible to directly measure it. In this study, surface temperatures of the 12.8W LED bulb was measured for 5 points using a data logger and compared with the simulated results using a thermal simulator based on FVM (finite volume method) to secure a reliability of the simulation. Effects of some factors such as lens, emissivity and air inlet were investigated using simulation works and then the results were analysed.

축대칭 열복사 해석을 위한 방향 미분항의 고찰 (Investigation of the Angular Derivative Term for the Analysis of Axisymmetric Thermal Radiation)

  • 김만영;백승욱;김기완
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.620-627
    • /
    • 2003
  • Radiative heat transfer in an axisymmetric enclosure with absorbing, emitting, and scattering medium is studied here by using the different methods such as MDOM, FVM, and FVM2 with emphasis on the treatment of angular derivative term, which appears in a curvilinear coordinates due to angular redistribution. After final discretization equation for FVM2 is introduced by using the step scheme and directional weights, present approach is validated by applying it to three different benchmarking problems with absorbing, emitting, and scattering medium.

FVM-FEM 결합 기법을 이용한 압축성 이상 유동과 변형 가능한 구조물의 상호작용 수치해석 (Numerical simulation of deformable structure interaction with two-phase compressible flow using FVM-FEM coupling)

  • 문지후;김대겸
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.35-41
    • /
    • 2020
  • We conduct numerical simulations of the interaction of a deformable structure with two-phase compressible flow. The finite volume method (FVM) is used to simulate fluid phenomena including a shock wave, a gas bubble, and the deformation of free surface. The deformation of a floating structure is computed with the finite element method (FEM). The compressible two-phase volume of fluid (VOF) method is used for the generation and development of a cavitation bubble, and the immersed boundary method (IBM) is used to impose the effect of the structure on the fluid domain. The result of the simulation shows the generation of a shock wave, and the expansion of the bubble. Also, the deformation of the structure due to the hydrodynamic loading by the explosion is identified.

Cold Flow Simulation of $SF_{6}$ Puffer Circuit Breaker

  • Bae, Chae-Yoon;Jung, Hyun-Kyo;Shin, Sang-In;Park, Oh-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.121-128
    • /
    • 2001
  • Numerical schemes for the simulation of the cold gas flow in the SF6 puffer type circuit breaker is presented. The governing equation is axisymmetric compressible Euler Equation and FVM is used to analyze the behavior of flow. The upwind scheme is used to avoid numerical instability and MUSCL is used to obtain high order accuracy. For the efficient calculation, AF-ADI scheme is used. The simulation result shows good agreement with the experimental data.

  • PDF

경사밭 고랑멀칭 방법에 따른 비점오염 저감효과 평가 (Evaluation of Furrow Mulching Methods for Controlling Non-Point Source Pollution Load from a Sloped Upland)

  • 엽소진;김민경;김명현;방정환;최순군
    • 한국농공학회논문집
    • /
    • 제64권3호
    • /
    • pp.33-43
    • /
    • 2022
  • South Korea's agricultural nitrogen balance and phosphorus balance rank first and second, respectively, among OECD countries, and proper nutrient management is required to preserve the water quality of rivers and lakes. This study evaluates the effects of furrow mulching on the reduction of non-point source pollution (NPS) load from a sloped upland. The study site was Wanju-gun, Jeollabuk-do, and the survey period was from 2018 to 2019. The slope of the testbed was 13%, and the soil type was sandy loam. The cropping system consisted of maize-autumn Chinese cabbage rotation. The testbed was composed of bare soil (bare), control (Cont.), furrow vegetation mulching (FVM), and furrow nonwoven fabric mulching (FFM) plots. Runoff was collected for each rainfall event with a 1/100 sampler, and the NPS load was calculated by measuring the concentrations of SS, T-N, and T-P. The NPS load was then analyzed for the entire monitoring and crop cultivation periods. During the monitoring period, the effect of reducing the NPS load was 1.5%~44.5% for FVM and 13.1%~55.2% for FFM. During the crop cultivation period, it was 1.2%~80.5% for FVM and 27.0%~65.1% for FFM, indicating that FFM was more effective than FVM. As the NPS load was fairly high during the crop conversion period, an appropriate management method needs to be implemented during this period.

분기배관의 압력강하에 관한 연구 (A Study on the Pressure Drops of T-Branch Pipes)

  • 남준석;백창선;권순관;김동현;민경탁;김병곤;이성호
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.272-277
    • /
    • 2008
  • 본 연구는 분기배관을 물계통 소화설비에 적용할 경우 정확한 등가길이를 제시하고자 수행하였다. 등가길이 측정위치를 예측하고자 분기배관의 압력강하에 대해 유한체적법을 이용하여 확인한 후 측정위치를 결정하였고 그 위치에서 압력손실시험을 실시하였다. 측정된 값의 정확성을 판단하기 위해 해석결과와 비교하였고 두 값이 유사함을 알 수 있었다. 본 연구의 결과로 분기배관의 압력손실측정위치를 주방향의 입구측은 주배관 호칭의 20배, 출구측은 주배관 호칭의 10배, 분기방향의 출구측은 주배관 호칭의 20배로 제안하였다.

동하중을 받는 원통형 액화연료 탱크의 배플에 따른 슬로싱 저감 특성 (Sloshing Reduction Characteristics to Baffle for Cylindrical Liquefied Fuel Tank subject to Dynamic Load)

  • 구준효;조진래;정의봉;김당주
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.950-959
    • /
    • 2009
  • Liquid fluctuation called sloshing within liquid-storage tank gives rise to the significant effect on the dynamic stability of tank. This liquid sloshing can be effectively suppressed by installing baffles within the tank, and the suppression effect depends strongly on the design parameters of baffle like the baffle configuration. The present study is concerned with the parametric evaluation of the sloshing suppression effect for the CNG-storage tank, a next generation liquefied fuel for vehicles, to the major design parameters of baffle, such as the baffle configuration, the installation angle and height, the hole size of baffle. The coupled FEM-FVM analysis was employed to effectively reflect the interaction between the interior liquid flow and the tank elastic deformation.