• Title/Summary/Keyword: FUSE

Search Result 534, Processing Time 0.025 seconds

Character Analysis of Micro Fuse Fusing as a function of De-Rating technique (디레이팅 기법에 의한 마이크로 퓨즈 용단의 특성 분석)

  • Kim, Do-Kyeong;Kim, Jong-Sick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.8-13
    • /
    • 2015
  • Recently, Illumination industry of LED module has been focused to industry technology for energy conservation of nation. The LED device is excellent to power efficiency due to semiconductor light source element. And the application to the lighting circuit technology can be designed to the sensitive lighting system for human sensitivity control. In this paper, as a process for analyzing the operating temperature of standardized electronic device including LED device has analyzed about fusing character with in designed micro fuse for electronic device protection from the over current. Using the de-rating technique, which is performed to micro fuse fusing test in the range of $-30^{\circ}C{\sim}120^{\circ}C$ thermostatic chamber. To the output data in each temperature zone, it is performed to first-order linear fitting. Additionally, applying the resistance temperature coefficient and statistical data for the reliable analysis has derived to the metal element resistance of micro fuse with temperature change of the thermostatic chamber. As a research result, The changed temperature effect of thermostatic chamber was confirmed regarding fusing time change.

An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse (고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구)

  • Lee, Dong-Hoon;Song, Hwa-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

Implementation of Vision System combining Character and Color Recognition (문자 및 색 인식을 혼용한 검사시스템의 구현)

  • Yang, Woo-Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.221-225
    • /
    • 2016
  • This paper is about vision system that exhibits automatic examination of the conditions of fuses and relay boxes using a camera. Proposed vision system is composed of three parts: image acquisition, vision algorithm, and user interface. The image acquisition part is composed of illumination and optics. The vision algorithmis the examining part, using the grabbed fuse box image. Lastly, user interface is divided into two parts, user interface for registering features of fuse box and user interface for examination operation.

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Numerical Study on the Strength Safety of a Fuse Cock Valve (퓨즈콕 밸브의 강도안전성에 관한 수치적 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.1-6
    • /
    • 2015
  • In this paper, the strength safety of a fuse cock main body has been analyzed by the finite element method. The stress and displacement behaviour characteristics have been investigated for thickness variations at the region of (T) between a ball valve and a fuse cock safety connector. The FEM analyzed results recommend that the optimized thickness at the region of (T) is from 1.55mm to 1.6mm for the supplied gas pressure of 1.5~3.5MPa. This is considered for the optimized strength safety and light weight of a fuse cock main body.

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Design of a Miniature Fuse with High Breaking Capacity and Load Life Using a Ceramic Powder of Extinguishing an Electric Arc (아크 소호용 세라믹 분말을 이용한 높은 차단용량 및 고내구성을 갖는 초소형 퓨즈 설계)

  • Kang, Chang yong;Jin, Sang Jun;Lee, Ye Ji;Youn, Jae Seo;Noh, Seong yeo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.327-332
    • /
    • 2019
  • Recently, inverter control systems have attracted immense attention to increase the energy efficiency. However, such systems use repeated on/off high currents for linear operation control, instead of the prevalent step variable current control method. Hence, there arise concerns of personal and property damage, especially due to the durability, explosive characteristics, and operating speed of the fuse, which is responsible for safety and is one of the internal components using current control. Therefore, in this paper, we propose an IEC60127-4 SMD sub-miniature fuse, consisting of Ag-Cu alloys and ceramic powder for arc soothing. The IEC60127-4 SMD sub-miniature fuse has high durability and cut-off capacity, and operates safely in dangerous circumstances caused by the inverter control system.

pNFS Metadata Server Design based on FUSE (FUSE 활용 pNFS 지원 메타데이터 서버 설계)

  • Kim, Soo-Young;Kim, Hong-Yeon;Kim, Young-Kyun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.1-3
    • /
    • 2012
  • 네트워크 환경에서 가장 범용적으로 사용되는 파일시스템인 NFS는 클라이언트 수가 증가할수록 I/O 병목 현상이 심각하게 발생한다. 이를 해결하기 위해 클라이언트가 직접 데이터 서버에 연결하여 I/O 처리를 병렬화한 NFS 버전s 4.1 표준이 제정되었다. 본 논문에서는 이러한 pNFS를 지원하는 메타데이터 서버를 사용자 영역에서 손쉽게 개발할 수 있도록 FUSE를 활용하는 방안을 제안한다.

A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles (차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구)

  • Ryu, Su-uk;Park, Kyoung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

The Study of FUSE Installing of PT in the trend of Digitalization and Convergence of Power Machinery. (디지탈화 및 복합화된 전력기기 변성기용 퓨즈 설치의 문제점)

  • Ok Yeon Ho;Lee Hyoung Mook;Hong Yeong Jae;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.357-359
    • /
    • 2004
  • Fuse is the initial equipment of Protective Relay The installation standard of Fuse has been used for long time in Power Facilities. However according to the innovative development of Electric & Electronic element(=semiconductor) Technology, Protective Relay and other Power Equipments are being changed into Digitalization and Multi-Functional Convergence. In contrast with it, the installation standard of Fuse is just the same. There is a need to give careful consideration to it. This study will bear a Part of producing a safe and efficient Power by examining the current installation of primal 8f secondary 1'use in multi-functional PT of Power plant, giving a problem careful consideration and suggesting suitable countermeasures.

  • PDF