• Title/Summary/Keyword: FTIR Spectrometry

Search Result 45, Processing Time 0.03 seconds

The Hydrolysis Measurement of Cyclodextrins Using FTIR-ATR Spectrometry (FTIR-ATR 분광법을 이용한 사이클로덱스트린의 가수분해 측정)

  • Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.549-557
    • /
    • 2000
  • FRIR-ATR spectrometry has been used to monitor the aqueous reactions of compounds without distinct chromophores in ultraviolet and visible regions. For example, hydrolysis reactions of ${\alpha}$-cyclodextrin and ${\gamma}$-cyclodextrin in acidic aqueous solution were studied. FTIR-ATR method has been used for the monitoring of cyclodextrin hydrolysis in 1.0 M. 0.5 M, and 0.1 M HCl solutions, respectively. We also found that the hydrolysis of ${\alpha}$-cyclodextrin produced glucose, but the hydrolysis of ${\gamma}$-cyclodextrin proceeded further to give more fragmented products than glucose.

  • PDF

FTIR Characterization on Treated Gem Stone Sapphires (보석용 처리 사파이어의 FTIR분석)

  • 송오성;이기영;이정임;김민규;최은집
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.17-21
    • /
    • 2003
  • It has been difficult to characterize the value of treated sapphires for gem stones with bare eyes. Color enhancing treatments by diffusion and annealing became sophisticated and customers and gemologists had asked a non-destructive and fast characterization method. We suggest that Fourier transformation infra-red (FTIR) offers to characterize the cobalt-doped synthetic sapphires successfully in 3 minutes. Our results imply that FTIR may be employed in jewelry business to identify the treated sapphires in quantitative way.

  • PDF

Analysis of sampling noise effect of Interferometer on FTIR Spectrometer (FTIR 분광용 간섭계의 샘플링 잡음 영향 분석)

  • Bae, Hyo-Wook;Park, Do-Hyun;Ra, Sung-Woong;Choi, Seung-Ki
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.10-17
    • /
    • 2007
  • FTIR(Fourier Transform Infrared) spectrometry is a useful method to obtain infrared spectra of materials in gas phase by registering the interferogram of a target material using an interferometer, and then performing a Fourier transform on the interferogram to obtain the spectrum. In this paper, sampling noise effect on signal processing of the rapid scan interferometer was studied with relation to sampling the interferogram points at the improper location and empirically verified.

Hard Tissue Analysis of NMR after Fluoride Administration

  • Kim, Hye-Young;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.599-602
    • /
    • 2016
  • Fluoride (F) is an important element for the mineralization of body tissues. The purpose of this study was to administer fluoride prenatally to rats to evaluate its beneficial concentration for rat bone using microstructural analysis, to analyze its effect on the bone structure, and to evaluate the effect of its transfer through rat placenta. Fourier transform infrared spectroscopy (FTIR) and nuclear magnetic resonance spectrometry (NMR) were performed. The $^{19}F$ NMR and $^{31}P$ NMR signals suggested the existence of fluoride ions in the apatite lattice because the signals were caused by the fluoride ions that were coupled to the phosphate atoms and were affected in the phosphate phases other than the element phases in the apatite. Consequently, if it was not affected too much, the desirable concentration of prenatal fluoride treatment could have a helpful effect on the bone crystal structure through placental fluoride transfer.

Removal of Pb2+ ion from aqueous solution Using crab shell treated by acid and alkali (산-염기 처리한 게 껍질에 의한 수풍의 납 이온 제거)

  • 김동석
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.469-476
    • /
    • 2003
  • In order to examine the pre-treatment effect of crab shell en Pb$^{2+}$ removal by crab shell in aqueous solution, acid and alkali pre-treated crab shell were used. Electron microscopy techniques such as TEM (transmission electron microscopy) and SEM (scanning electron microscopy), and EDX (energy dispersive X-ray) and FTIR (Fourier transform infrared) spectrometry techniques were used to investigate the process of Pb$^{2+}$ removal by acid and alkali pre-treated crab shell. The Pb$^{2+}$ removal by acid pre-treated crab shell was much lower than that by untreated crab shell because of the decrease of CaCO$_3$ from the crab shell. However, the Pb$^{2+}$removal by alkali pre-treated crab shell increased compared to that by untreated crab shell. The results were confirmed by TEM, SEM, EDX and FTIR.nd FTIR.

Correlation between Physico-Mechanical and Rheological Properties of Rubber Compounds Based on NR-BR with C-C Gel Content in Polybutadiene (NR-BR 기반 고무소재에서 폴리부타디엔의 C-C 겔 함량과 물리기계적, 유변학적 특성 사이의 상호관계)

  • Ganjali, Saeed Taghvaei;Motiee, Fereshteh;Tabatabaie, Zohreh Ghazi
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.425-433
    • /
    • 2014
  • In this study, microstructure and gel content (C-C) of polybutadiene rubber (PBR) were investigated using various techniques including ASTM D 3616, attenuated total reflectance Fourier transform infrared spectrometry (ATR FTIR), differential scanning calorimetry (DSC) and nuclear magnetic resonance spectroscopy (NMR). The ATR FTIR spectra of the samples were investigated to determine the cis, trans, 1, 2-vinyl and the C-C gel content in PBR. The absorbance ratios of specific peaks in different grades of PBR were correlated with the C-C gel content measured by the ATR FTIR techniques. Physico-mechanical and rheological properties of rubber compounds based on BR with various amounts of gel were determined. The results showed that there is an acceptable correlation between these properties and the C-C gel content of PBR.

Fast Remote Detection Algorithms for Chemical Gases Using Pre-Detection with a Passive FTIR Spectrometer (수동형 FTIR 분광계에서 초동 탐지 기법을 이용한 고속 원거리 화학 가스 탐지 알고리즘)

  • Yu, Hyeonggeun;Park, Dongjo;Nam, Hyunwoo;Park, Byeonghwang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.744-751
    • /
    • 2018
  • In this paper, we propose a fast detection and identification algorithm of chemical gases with a passive FTIR spectrometer. We use a pre-detection algorithm that can reduce the spatial region effectively for gas detection and the candidates of the target. It is possible to remove background spectra effectively from measured spectra with the least-squares method. The CC(Correlation Coefficients) and the SNR(Signal-to-Noise Ratio) methods are used for the detection of target gases. The proposed pre-detection algorithm allows the total process of chemical gas detection to be performed with lower complexity compared with the conventional algorithms. This paper can help developing real-time chemical detection instruments and various applications of FTIR spectrometers.

Spectroscopical Analysis of SiO2 Optical Film Fabricated by FHD(Flame Hydrolysis Deposition) (FHD(Flame Hydrolysis Deposition)공정으로 제작된 SiO2 광도파막의 분광학적 분석)

  • Kim, Yun-Je;Shin, Dong-Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.896-901
    • /
    • 2002
  • Since many process parameters of FHD(Flame Hydrolysis Deposition) are involved in forming multi-component amorphous silica film ($SiO_2-B_2O_3-P_2O_5-GeO_2$), it has not been easy to predict the optical, mechanical and thermal properties of deposited film from the simple process parameters, such as source flow rate. Furthermore, the prediction of final composition of film becomes even more difficult after sintering at high temperature due to the evaporation of volatile dopants. The motivation of the study was to clarify the quantitative relationship between simple process parameters such as the flow rate of source gases and resulting chemical composition of sintered film. Hence, the compositional analysis of silica soot by FTIR(Fourier Transformation Infrared Spectroscopy) and ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectrometry) under the control of the amount of dopant was carried out to obtain the quantitative composition. By measuring spectrum of absorbance from FTIR, the compositional change of B-O, Si-O, OH($H_2O$) in silica film was measured. The concentrations of these dopants were also measured by ICP-AES, which were compared with the FTIR result. The final quantitative relationship between simple process parameters and composition was deduced from the comparison between two results.

Polystyrene Biodegradation Using Zophobas morio

  • Choe, In-Hak;Gi, Ye-Rim;Yang, Su-Jeong;Lee, Seo-Ha;Lee, Ui-Jeong;Lee, Jun-Hyeop;Jeong, Tae-Ho
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2020.10a
    • /
    • pp.208-208
    • /
    • 2020
  • The aim of this study was to investigate changes in the weight of Zophobas morio larvae and mass of polystyrene foam when the larvae were fed polystyrene for 27 days. Fourier-transform infrared (FTIR) spectrometry was used to determine whether the polystyrene was broken down by the larvae. Forty Z. morio larvae (four replicates with 10 larvae per replicate) were reared in a chamber under controlled conditions with polystyrene foam blocks as their sole diet. The weight of the Z. morio larvae and mass of the polystyrene foam decreased as a function of time. The average weight of the larvae and mass of the polystyrene foam blocks decreased by 16.3 and 6.5%, respectively, over the 27-day period. The FTIR spectrum of Z. morio larvae fed with polystyrene foam did not reveal the unique peaks associated with polystyrene. In conclusion, this study suggests the possibility of using Z. morio larvae as a management technology for degrading waste plastics without a negative environmental effect. Key words : FTIR spectra, plastic biodegradation, polystyrene foam, Zophobas morio larvae.

  • PDF

FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.