• Title/Summary/Keyword: FT-IR Spectrometer

Search Result 123, Processing Time 0.033 seconds

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

The quantitative analysis of combustive gases on fire by remote passive open path FT-IR spectrometer (Passive open-path FT-IR spectrometer를 사용한 원거리 화재 연소 가스 정량 분석)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.120-124
    • /
    • 2013
  • It was studied to analyze the $CO_2$, CO, $SO_2$ standard gases of combustion gases by the open path FT-IR spectrometer with passive mode for remote analysis of air pollutant and volcano gases without IR lamp. As result, it was confirmed to have good linearity with more than 0.9 as correlation coefficients on the calibration curve of $CO_2$, CO concentration by MLR method. But in the case of $SO_2$, because the correlation coefficients were 0.88, the linearity could be lower. Finally, the concentration of three gases was predicted on in-site fire experiment under the condition of quantitative analysis. It could measure high $CO_2$ concentration as predicted result, but didn't measure the CO and $SO_2$. According to the result, it was possible to measure the combustion gases to long distance by only open path FT-IR spectrometer without infrared lamp.

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.

Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer (퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정)

  • Jeon, Sang-Ho;Yoo, Nam-Joon;Jo, Jae-Heung;Park, Chul-Woung;Park, Seung-Nam;Lee, Geun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.400-407
    • /
    • 2008
  • An Instrument to measure normal spectral emissivity is built using a Fourier Transform-Infrared (FT-IR) spectrometer. The instrument is composed of four main parts, reference blackbody, sample furnace, optics system, and FT-IR spectrometer. Measurement ranges of temperature and wavelength are $200^{\circ}C{\sim}500^{\circ}C$ and $3.5{\mu}m{\sim}20{\mu}m$, respectively. Measured emissivity of the reference blackbody is greater than 0.9993 with combined relative uncertainty less than 0.69%, which can be considered an ideal blackbody. We studied the emissivity of opaque alumina, graphite, anodized aluminum, and steel (IMS 200). It is shown that emissivity increases with the roughness of the steel (IMS 200) surface.

The study for VOCs analysis in long path by open path FT-IR spectrometer (Open path FT-IR spectrometer를 사용한 원거리의 VOCs 측정에 관한 연구)

  • Cho, Nam Wook;Cho, Won Bo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.108-113
    • /
    • 2014
  • The harmful materials as volatile organic compounds (VOCS) that is easy for gas to be changed from liquid on ambient temperature, those should be controlled by Korea Chemicals Management Association. The VOCs samples should be collected directly in place so that those could be analyzed. Generally but it couldn't avoid to have the risk of analyst. Moreover, if there is the place limited to entrance, it is impossible to collect directly and measure. Owing to such problem, it tried to be solved by open path FT-IR spectrometer that could be studied on the combustion gases within long path and VOCs samples were tried to measure to large volume by remote and real time. Firstly, it was to investigate optimized measured length between the system and benzene sample of VOCs. As result, The optimized measured length was confirmed with 15 meter length and the qualitative analysis could be measured on seven VOC samples. The calibration curve as quantitative analysis of benzene samples could be worked. On the basis of the result, the system as remote monitor could show to have potentiality.

Comparison of pigment in automotive solid color paints by FT-IR and XRF spectroscopy for forensic aspect (법과학적 관점에서 FT-IR과 XRF를 이용한 단색 페인트의 안료 비교)

  • Park, Ha-Sun;Kim, Ki-Wook;Heo, Sangcheol;Ryu, Seung-Jin;Lee, Hyunik;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.245-255
    • /
    • 2013
  • Identification of paint on victim's clothing and a vehicle are valuable for forensic examination when investigating hit-and-run accidents. Automotive paints on clothes are used to prove a victim caused by traffic accident and to identify a suspected vehicle. The comparison of transferred paints between victim's vehicle and suspected vehicle can be an important evidence in reconstructing the accident situation and in discovering the truth. The paints such as white, yellow, red, blue, or black are hard to examine particle shape under a stereomicroscope because of it is not included aluminum, pearl, and mica flakes in the pigments. The aim of this study under forensic aspect is to compare pigment among basecoat layers of solid paints by identifying inorganic elemental compositions and binder resins of pigments using by micro-FT-IR and micro-XRF spectrometer. The pigment samples were analyzed by using two methods of FT-IR: Reflectance and ATR method. Two methods of FT-IR were useful in discriminating binder resins of pigments by comparing characteristic peaks and patterns of spectra. Also, XRF spectrometer could identify the elemental compositions in inorganic pigments of trace paints which are difficult to compare the identification by FT-IR.

Composition and Temperature Dependence of Structural Changes in Borosilicate Glasses by Spectrometer (분광계에 의한 Borosilicate계 글라스의 조성 및 온도의존성 평가)

  • Park Sung-Je;Ryu Bong-Ki
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.786-790
    • /
    • 2005
  • We investigated the particularity of temperature and composition changes in $xNa_2O{\cdot}(52.5-x)B_2O_3{\cdot}47.5SiO_2$ glasses by use of FT-IR, $^{11}B$ NMR, Raman spectrometer. From FT-IR and $^{11}B$ NMR spectrometer, we thought that tetrahedral boron, $BO_4$ units are created $N_4$ increasing tendency generated near $600^{\circ}C$. It's expected that composition ana heat treatment directly contributed to structural changes, this changes are following to $Na_2O$ increasing or decreasing. caused by $N_4\;and\;BO_4$ units are caused by relatively increasing or decreasing in the glasses' structure. Particularly, $BO_4$ units are converted to $BO_3$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x<18(R<0.5,\;R=Na_2O/B_2O_3\;mol\%)$. On the order hand, $BO_3$ units are converted to, $BO_4$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x{\geq}18\;(R>0.5)$. This particularity of composition and temperature dependence of structural changes are similarly represented by Raman analysis results.

Synthesis of Silica using Silk Sericin without Hydrolysis of Tetraethyl Orthosilicate

  • Lee, Ji Young;Lee, Ki Hoon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.2
    • /
    • pp.298-302
    • /
    • 2013
  • In this study, the effect of sericin on synthesis of the silica was investigated. Using the mixture of sericin solution and tetraethyl orthosilicate (TEOS), it was confirmed that silica could be synthesized in the presence of sericin, which was verified by thermal gravimetric analysis (TGA), Fourier-transformed infrared spectrometer (FT-IR) and nuclear magnetic resonance spectrometer (NMR) analysis. The TGA and FT-IR data revealed that silica-sericin complex was formed as a final product. Based on the TGA result, the content of silica and sericin in the complex would be 87 and 13%, respectively. The degree of silica condensation was higher than the natural biosilica. It could be concluded that sericin can induce the synthesis of silica directly from TEOS, which is similar to silicatein from marine sponges.

Far Infrared Radiation Characteristics of Germanium Compounds (게르마늄 화합물의 원적외선 방사특성)

  • Lee, Hyun-Kyung;Lee, Kyung-Mee
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.597-603
    • /
    • 2006
  • In order to study the effects of $GeO_{2}$ contents in $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds on far infrared ray radiation, we investigated the sample of $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ using TG-DTA, XRD, FT-IR spectrophotometer and FT-IR spectrometer. The far infrared ray emissivity and emission power were increased with the increase of $GeO_{2}$ contents in $XSiO_{2}{\cdot}YGeO_{2}$ and $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds. The far infrared ray emissivity and emission power of $XSiO_2{\cdot}YGeO_2$ compounds were higher than those of $XSiO_{2}{\cdot}YNa_{2}O{\cdot}ZGeO_{2}$ compounds.