• Title/Summary/Keyword: FRP Tube

Search Result 75, Processing Time 0.056 seconds

Behaviour of FRP composite columns: Review and analysis of the section forms

  • Rong, Chong;Shi, Qingxuan;Zhao, Hongchao
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.125-137
    • /
    • 2020
  • As confining materials for concrete, steel and fibre-reinforced polymer (FRP) composites have important applications in both the seismic retrofit of existing reinforced concrete columns and in the new construction of composite structures. We present a comprehensive review of the axial stress-strain behaviour of the FRP-confined concrete column. Next, the mechanical performance of the hybrid FRP-confined concrete-steel composite columns are comprehensively reviewed. Furthermore, the results of FRP-confined concrete column experiments and FRP-confined circular concrete-filled steel tube experiments are presented to study the interaction relationship between various material sections. Finally, the combinations of material sections are discussed. Based on these observations, recommendations regarding future research directions for composite columns are also outlined.

Composite Hollow Bushing의 변위 특성 해석에 관한 연구

  • Jo, Han-Gu;Kim, Gwang-Yong;Seong, Yun-Gi;Lee, Cheol-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.113-113
    • /
    • 2010
  • 본 논문에서는 composite hollow bushing에 사용되는 FRP tube의 winding 각도 및 장력 변화에 의한 변위 특성을 해석하였다. Winding 각도 및 장력에 따라 FRP tube의 인장 및 굽힘강도 특성이 변화되므로 최적의 composite bushing의 설계하기 위해서는 이에 대한 해석 및 시험이 요구된다. 따라서, 본 논문에서는 와인딩 각도 및 와인딩 장력에 따른 굽힘강도와 변위에 대하여 고찰하였으며, 와인딩 장력에 따른 각각의 특성에 대해서도 검토하였다.

  • PDF

Minimum Thickness of FRP Member Applicable to FRP-Concrete Composite Deck (FRP-콘크리트 합성 바닥판에 적용 가능한 FRP 부재의 최소 두께)

  • Cho, Keun-Hee;Park, Sung-Yong;Kim, Sung-Tae;Cho, Jeong-Rae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.317-320
    • /
    • 2006
  • In order to determine a minimum thickness of the pultruded GFRP panel as a structural member, some experimental studies were performed. GFRP tubes with 2mm, 4mm, 6mm thickness were manufactured by pultrusion process. First, coupon tests for finding mechanical properties were carried out. Comparisons between test results and analysis results based on classical laminate theory showed large differences in case of 2mm, 4mm specimens. The reason is that it is difficult to apply appropriate pultruding force and keep layered stitched fabric flat for the pultrusion process of complex shaped FRP member with small thickness. On the consequence, we decide 6mm as a minimum thickness of FRP member. Second, 4-point bending tests were performed and the results with compared with numerical analysis. The behavior of FRP tube can be exactly predicted by numerical analysis if buckling analysis is included.

  • PDF

Study on Optimum Design for constitution part of Composite Insulator (Composite Insulator 구성 부품에 대한 최적 설계 연구)

  • Chung, Young-Soo;Choi, Sung-Man;Jang, Yoon-Ki;Lee, Dong-Woen;Kim, Jeong-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1181-1186
    • /
    • 2008
  • Insulators which are used in the domestic electrical industries are mostly depended on importation from some advance countries. Even though insulators which are made of ceramic material have been mostly used domestically, the ratio of usage on composite insulators is recently being increased because of difficulties in manufacturing and high cost regarding ceramic stuffs. In this research, we are trying to develop the composite insulators which are very efficient in insulation regardless of the matter of weight. Even though the technique of manufacturing composite insulator are quite generalized worldwide at the moment, one of the most important issue is to keep security on the know-how that an ingredient of insulated material named 'SF6 gas' is included. Therefore, The aim of this paper is to improve the bonding force and air tight property between two components of composite insulator, Flange and FRP Tube.

  • PDF

Mechanical behaviour of concrete filled double skin steel tubular stub columns confined by FRP under axial compression

  • Wang, Jun;Liu, Weiqing;Zhou, Ding;Zhu, Lu;Fang, Hai
    • Steel and Composite Structures
    • /
    • v.17 no.4
    • /
    • pp.431-452
    • /
    • 2014
  • The present study focuses on the mechanical behaviour of concrete filled double skin steel tubular (CFDST) stub columns confined by fiber reinforced polymer (FRP). A series of axial compression tests have been conducted on two CFDST stub columns, eight CFDST stub columns confined by FRP and a concrete-filled steel tubular (CFST) stub column confined by FRP, respectively. The influences of hollow section ratio, FRP wall thickness and fibre longitudinal-circumferential proportion on the load-strain curve and the concrete stress-strain curve for stub columns with annular section were discussed. The test results displayed that the FRP jacket can obviously enhance the carrying capacity of stub columns. Based on the test results, a new model which includes the effects of confinement factor, hollow section ratio and lateral confining pressure of the outer steel tube was proposed to calculate the compressive strength of confined concrete. Using the present concrete strength model, the formula to predict the carrying capacity of CFDST stub columns confined by FRP was derived. The theoretically predicted results agree well with those obtained from the experiments and FE analysis. The present method is also adapted to calculate the carrying capacity of CFST stub columns confined by FRP.

Experimental and analytical investigations of CFFT columns with and without FRP bars under concentric compression

  • Khan, Qasim S.;Sheikh, M. Neaz;Hadi, Muhammad N.S.
    • Steel and Composite Structures
    • /
    • v.30 no.6
    • /
    • pp.591-601
    • /
    • 2019
  • This research study investigates experimentally and analytically the axial compressive behaviour of Concrete Filled Fiber Reinforced Polymer Tube (CFFT) columns with and without Fiber Reinforced Polymer (FRP) bars. The experimental program comprises five circular columns of 204-206 mm outer diameter and 800-812 mm height. All columns were tested under concentric axial compressive loads. It was found that CFFT columns with and without FRP bars achieved higher peak axial compressive loads and corresponding axial deformations than conventional steel reinforced concrete (RC) column. The contribution of FRP bars was about 12.1% of the axial compressive loads carried by CFFT columns reinforced with FRP bars. Axial load-axial deformation ($P-{\delta}$) curves of CFFT columns were analytically constructed, which mapped well with the experimental $P-{\delta}$ curves. Also, an equation was proposed to predict the axial compressive load capacity of CFFT columns with and without FRP bars, which adequately considers the contributions of the circumferential confinement provided by FRP tubes and lower ultimate strength of FRP bars in compression than in tension.

Development of Design Program for CFFT Structure (CFFT구조의 설계프로그램 개발)

  • Choi, Young-Min;Hwang, Yoon-Koog;Lee, Young-Ho;Lee, Jung-Howan;Kim, Dong-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.549-552
    • /
    • 2009
  • 본 논문에서는 재료적 성능이 우수하며 경량재료로서 최근 건설구조물에 활용하고자 하는 연구가 활발히 진행되고 있는 섬유보강재료(FRP : Fiber Reinforced Polymer)를 이용한 합성구조인 CFFT(Concrete Filled FRP Tube)의 설계프로그램을 개발하여 제안하고자 하였다. 먼저, CFFT구조는 FRP관에 의해 철근콘크리트가 구속되는 구조로서 기둥과 같이 축력이 도입되는 경우 포아송효과에 의한 변형을 FRP관이 구속효과를 줌으로써 콘크리트의 역학적 거동을 개선하게 되는데 본 연구에서는 실험에 의해 검증된 식을 제시하였으며 이를 바탕으로 CFFT구조를 설계하는 알고리즘을 제안하였다. 또한 CFFT구조는 FRP관의 구속으로 인해 고강도콘크리트와 긴장재의 도입이 가능한 구조로서 이에 대한 설계도 포함하였다. 그러나 이방성재료인 FRP의 설계와 동시에 FRP관에 의한 구속효과를 고려하는 CFFT구조의 설계는 일반 실무설계자들에게는 다소 난해한 작업으로써 전산화 설계프로그램의 필요성이 대두되어 본 연구에서 CFFT구조의 설계프로그램을 개발하였다. 개발된 설계프로그램의 검증을 위해 일반 철근콘크리트기둥, CFFT기둥, 고강도콘크리트와 PS긴장재를 도입한 CFFT기둥을 설계한 결과, 매우 실용적이며 타당한 설계가 수행될 수 있음을 확인하였다.

  • PDF

Structure of Station Class Lightning Arresters and Electrical Characteristics of ZnO Varistor Blocks (발변전용 피뢰기의 구조 및 ZnO 바리스터 소자의 전기적 특성)

  • Cho, Han-Goo;Han, Se-Won;Lee, Un-Yong;Yoon, Han-Soo;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1158-1161
    • /
    • 2004
  • This paper presents structural characteristics of station class lightning arresters and electrical characteristics of manufactured ZnO varistor blocks which are usable in those arresters. Three types of station class lightning arresters were investigated and those are a ceramic arrester, a FRP tube type polymer arrester, and a FRP rod type polymer arrester. Each arrester has merits and demerits with structural characteristics. In general, polymer arresters were made of silicon rubber for housing materials, FRP tube or rod for mechanical strength, ZnO blocks for electrical characteristics, and metal parts for electrical contact and the silicon rubber, the housing materials, was directly injected to the arrester module which was assembly composed of electrodes, ZnO blocks and FRP tube or rod, and to prevent the nonlinear electric fields distribution on upper parts of arresters, the grade ring was adopted to the upper electrodes. The reference voltage, nonlinear coefficient, residual voltage, and voltage ratio of manufactured ZnO varistors are 4.90kV, 50, 9.54kV, 1.94, respectively. Compared to designed electrical characteristics, the reference voltage was low for 600v and the voltage ratio was slightly high. However, the characteristics of discharge withstand was so excellent that the mechanical destruction does not occur at the impulse current of $8/20{\mu}s$ 10kA for 100 times.

  • PDF

Compression Strength Test of FRP Reinforced Concrete Composite Pile (FRP-콘크리트 합성말뚝 시편의 압축강도실험)

  • Lee, Young-Geun;Choi, Jin-Woo;Park, Joon-Seok;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.19-27
    • /
    • 2011
  • In this paper, we present a part of results to develop new type hybrid FRP-concrete composite pile (i.e., concrete filled fiber reinforced plastic circular tubes, hybrid CFFT, HCFFT). The purpose of this paper is to evaluate compressive loading capacity through compressive strength test. Before compressive strength test of HCFFT, we investigated mechanical properties of pultruded fiber reinforced plastic (PFRP) and filament winding fiber reinforced plastic (FFRP). For estimating the compressive strength of HCFFT, uni-axial compression strength tests of HCFFT compression members were conducted. The test variables are compressive strengths of concrete and thickness of FFRP. In addition, uni-axial compression strength tests of concrete filled fiber reinforced plastic circular tube (CFFT) except PFRP members were conducted. The test variable in the test is thickness of FFRP. From the test result, the compressive strength of the HCFFT in larger than compressive strength of CFFT as much as 47%. It can be observed that the uni-axial compressive strength of the HCFFT increased if the concrete strength and the thickness of exterior filament winding FRP tube increased. In addition, the finite element analysis result is compared with the experimental result. The difference between the experimental and FEM results is in the range of 0.14% to 17.95%.

Ablation Characteristic Study for Carbon Fabric/EPDM Chamber Insulation (Carbon Fabric을 삽입한 EPDM계 연소관 내열재 삭마 특성 연구)

  • Kim, Jin-Yong;Choi, Ji-Yong;Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man;Hahm, Hee-Cheol;Yun, Nam-Gyun;Rhee, Young-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • We developed the carbon fabric/EPDM chamber insulation in order to protect motor case with high intensity gas flow. A six-inch simulation motor connected with extension tube was designed to test ablation characteristic of insulation. High intensity gas flow was induced by a FRP disc with hole between motor and extension tube. After ground test, ablation depth of the carbon fabric/EPDM insulation was decreased compared to another insulations after ground static test.