• 제목/요약/키워드: FM receiver

검색결과 54건 처리시간 0.023초

텔레미터링기법을 이용한 공구 파손 검출에 관한 실험적 연구 (An Experimental Study on the Detection of Tool Failure Using Telemetering Technique)

  • Kim, W.S.;Lee, J.H.;Kim, D.H.
    • 한국정밀공학회지
    • /
    • 제13권11호
    • /
    • pp.100-105
    • /
    • 1996
  • In this paper presents a new technique (stain-telemetering) for detection of coated tool failure in face milling processes. In the cutter body, the strain signals received from the transmitter are transformed into frequency modulation(FM) signals in face milling processes. The receive which is placed near by the Vertical milling machine receives the FM signals, then the signals are sent to a computer, which shows the tool failure. In this paper, A on-line monitoring of the tool failure detection system based on the strain-telemetering apparatus has been represented.

  • PDF

이동통신에 적용한 랜덤 잡음 제거를 위한 IF stage 구현에 관한 연구 (A Study on the Implemanation of IF Stage for Reducing Random Noise in the Mobile Communications)

  • 이은기;박영철;차균현
    • 한국통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.572-579
    • /
    • 1992
  • 마지막으로 Quadrature FM검파기를 사용하여 90$^{\circ}$전이된 신호와 진폭제한된 신호를 합성하여 오디오 신호를 추출하였고 RSSI특성을 측정하였으며 오디오 특성을 기존의 1F모듈과 비교하였다.

  • PDF

Real Zero SSB 수신기에서 개선된 Linearizer 구현 (Improved Linearizer for use in Real Zero SSB Receiver)

  • 홍교영;김종한;김유창;김원후
    • 한국통신학회논문지
    • /
    • 제24권7A호
    • /
    • pp.1016-1021
    • /
    • 1999
  • RZ-SSB 신호로부터 원 신호를 복조하기 위해서는 FM 복조 후에 고차의 왜곡 성분을 제거하는 Linearizer를 설계하는 것이 중요하다. NTT의 Linearizer에는 반드시 Hilbert 변환이 필요하고 실제로 Linearizer의 성능 또한 이 Hilbert 변환의 성능에 좌우된다. 그러나 입력 신호 전 대역에 걸친 완전한 Hilbert 변환을 설계하는 것은 상당히 복잡하며 특히 저주파 영역에서는 더욱 어렵다. 이에, Hilbert 변환이 필요 없이 고차 왜곡 성분이 제거되는 새로운 방식의 Linearizer를 설계한다. 이 제안된 Linearizer는 기존 방식에 비해 상당히 간단하며 또한 쉽게 구현된다.

  • PDF

FFT를 이용한 열차 정보 추출 방법 (The Extraction of Train information using FFT)

  • 임관수;김기승;박상진;조용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.419-426
    • /
    • 1998
  • The information for operating the train should be transmitted to train, with extreme security. In our system, The information, such that the allowable velocity of the train, train existence in current area, and other data necessary for operating train, is transmitted in the form of FM signal. Received by the receiver located on train, the signal is filtered, demodulated, and analyzed for extracting the original information. The analysis of the demodulated signal is done through FFT algorithm using sliding slot. The simulation results shows the validity of the algorithm.

  • PDF

Development of an Equipment for Monitoring Current and Voltage on a Power Transmission Line

  • K. Kuwanami;E.Jishiuama;T Matsuda;I.Oota;H.Kuribayashi;N. Ueda;Ha, S.yata
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.233-236
    • /
    • 2000
  • A portable equipment that measures a current and voltage waveform of power transmission lines is pro-posed. In the equipment, the current and voltage, respectively, are detected by a loop coil and a capacitor clamped around the power lines. The detected data is transmitted by an FM wave to the receiver on the ground station. Since the receiver is isolated from the power lines, we do not require high potential insulators for the measurement of current and voltage. The proposed equipment is therefore, small-sized, light, and low in the cost of production. Experimental results presented here show that the equipment can monitor the current flowing in single wire over a ground plane and the potential of the wire.

  • PDF

레이더 펄스 압축 기술의 Barker Code에 관한 연구 (A Study on Barker Code of Radar Pulse Compression Technique)

  • 김민수;구융서;이영철
    • 한국전자통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.541-547
    • /
    • 2013
  • 레이더에서 거리분해능은 정확한 목표물 구분을 위해 판단하는 중요한 성능 파라미터이다. 기존의 아날로그 방식의 레이더시스템의 한계를 극복하기 위해, 현대 레이더 시스템 설계 목표는 적은 전송전력으로 거리분해능을 향상시키는 것으로 펄스압축기술에 대한 연구가 활발히 이루어지고 있다. 수신단에서 목표물 구분을 위해 펄스압축기술에 사용되는 송신신호의 변조방식은 크게 FM방식과 PM방식으로 나뉠 수 있다. 본 논문에서는 PM방식인 Barker Code를 이용하여 펄스압축 신호처리모듈을 구현하고 분석하였다.

A 0.25-$\mu\textrm{m}$ CMOS 1.6Gbps/pin 4-Level Transceiver Using Stub Series Terminated Logic Interface for High Bandwidth

  • Kim, Jin-Hyun;Kim, Woo-Seop;Kim, Suki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.165-168
    • /
    • 2002
  • As the demand for higher data-rate chip-to-chip communication such as memory-to-controller, processor-to-processor increases, low cost high-speed serial links\ulcorner become more attractive. This paper describes a 0.25-fm CMOS 1.6Gbps/pin 4-level transceiver using Stub Series Terminated Logic for high Bandwidth. For multi-gigabit/second application, the data rate is limited by Inter-Symbol Interference (ISI) caused by channel low pass effects, process-limited on-chip clock frequency, and serial link distance. The proposed transceiver uses multi-level signaling (4-level Pulse Amplitude Modulation) using push-pull type, double data rate and flash sampling. To reduce Process-Voltage-Temperature Variation and ISI including data dependency skew, the proposed high-speed calibration circuits with voltage swing controller, data linearity controller and slew rate controller maintains desirable output waveform and makes less sensitive output. In order to detect successfully the transmitted 1.6Gbps/pin 4-level data, the receiver is designed as simultaneous type with a kick - back noise-isolated reference voltage line structure and a 3-stage Gate-Isolated sense amplifier. The transceiver, which was fabricated using a 0.25 fm CMOS process, performs data rate of 1.6 ~ 2.0 Gbps/pin with a 400MHB internal clock, Stub Series Terminated Logic ever in 2.25 ~ 2.75V supply voltage. and occupied 500 * 6001m of area.

  • PDF

수중정보의 원격계측시스템에 관한 연구 (A Study on the Telemetric Measuring System of the Underwater Information)

  • 신형일
    • 수산해양기술연구
    • /
    • 제24권1호
    • /
    • pp.7-11
    • /
    • 1988
  • 수산, 해양자원을 개발함에 있어 가장 중요한 요소중의 하나인 해양환경요소를 효과적으로 측정하기 위해 원격제어장치를 제작하여 수온에 대한 원격제어실험을 행한 결과, 수은온도계로 직접 측정한 측정치와 원격제어 시스템에 의한 측정치는 수온 $12^{\circ}C~37^{\circ}C$ 범위에서는 완전정상관을 이루어, 본 원격계측 시스템은 수온의 원격제어에 효과적으로 사용할 수 있음을 확인할 수 있으며, 다른 수중정보의 원격제어에도 크게 활용될 수 있으리라 생각된다.

  • PDF

차세대소형위성2호 X대역 합성 개구 레이더용 송·수신 모듈의 설계 및 개발 (Design and Development of TRM for NEXTSat-2 X-band Synthetic Aperture Radar)

  • 김지흥;김동국;장일영
    • 한국항행학회논문지
    • /
    • 제28권2호
    • /
    • pp.193-200
    • /
    • 2024
  • 본 논문에서는 차세대소형위성2호의 X대역 합성 개구 레이더 (SAR; synthetic aperture radar)에 탑재하기 위한 송·수신 모듈의 설계 및 개발에 관하여 논한다. 모듈은 DDS를 통해 X 대역의 대상 주파수 범위에서 요구 대역폭을 갖는 첩(chirp) 신호를 생성하고, 송·수신 신호에 대한 주파수 변환 및 합성, 분배 그리고 주파수 합성기능을 수행한다. 제작된 모듈의 송신 경로는 최대 96.8 MHz 까지 총 28개의 대역폭을 갖는 신호를 생성하며, + 9.37 dBm 이상의 출력신호 세기를 갖는다. 수신 경로는 15.7 dB 이하의 최소 잡음지수를 가짐으로써, 요구되는 성능을 만족함을 확인하였다. 제작된 모듈은 차세대소형위성2호 비행모델 (FM; flight model)에 장착되었고, 2023년 5월 23일 누리호 3차 발사체로 발사되어 운용 중이다.

Primary somatosensory cortex and periaqueductal gray functional connectivity as a marker of the dysfunction of the descending pain modulatory system in fibromyalgia

  • Matheus Soldatelli;Alvaro de Oliveira Franco;Felipe Picon;Juliana Avila Duarte;Ricardo Scherer;Janete Bandeira;Maxciel Zortea;Iraci Lucena da Silva Torres;Felipe Fregni;Wolnei Caumo
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.113-127
    • /
    • 2023
  • Background: Resting-state functional connectivity (rs-FC) may aid in understanding the link between painmodulating brain regions and the descending pain modulatory system (DPMS) in fibromyalgia (FM). This study investigated whether the differences in rs-FC of the primary somatosensory cortex in responders and non-responders to the conditioned pain modulation test (CPM-test) are related to pain, sleep quality, central sensitization, and the impact of FM on quality of life. Methods: This cross-sectional study included 33 females with FM. rs-FC was assessed by functional magnetic resonance imaging. Change in the numerical pain scale during the CPM-test assessed the DPMS function. Subjects were classified either as non-responders (i.e., DPMS dysfunction, n = 13) or responders (n = 20) to CPM-test. A generalized linear model (GLM) and a receiver operating characteristic (ROC) curve analysis were performed to check the accuracy of the rs-FC to differentiate each group. Results: Non-responders showed a decreased rs-FC between the left somatosensory cortex (S1) and the periaqueductal gray (PAG) (P < 0.001). The GLM analysis revealed that the S1-PAG rs-FC in the left-brain hemisphere was positively correlated with a central sensitization symptom and negatively correlated with sleep quality and pain scores. ROC curve analysis showed that left S1-PAG rs-FC offers a sensitivity and specificity of 85% or higher (area under the curve, 0.78, 95% confidence interval, 0.63-0.94) to discriminate who does/does not respond to the CPM-test. Conclusions: These results support using the rs-FC patterns in the left S1-PAG as a marker for predicting CPM-test response, which may aid in treatment individualization in FM patients.