• Title/Summary/Keyword: FLOW-3D$^{(R)}$

Search Result 628, Processing Time 0.048 seconds

Numerical Simulation of Ship-induced Wave Using FLOW-$3D^{(R)}$ (FLOW-$3D^{(R)}$를 이용한 항주파 수치모의)

  • Kang, Young-Seung;Kim, Pyeong-Joong;Hyun, Sang-Kwon;Sung, Ha-Keun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.3
    • /
    • pp.255-267
    • /
    • 2008
  • Using the commercial CFD code FLOW-$3D^{(R)}$ which has an implicit General Moving Object (GMO) method, the ship-induced wave has been simulated. In the implicit GMO method of the FLOW-$3D^{(R)}$, a rigid body's motion which is either user-prescribed (prescribed motion) or dynamically coupled to fluid flow (coupled motion) can be computed with six degrees of freedom (DOF). The simulated horizontal wave patterns are agree with the wave patterns represented by depth Froude number. The model has been well-simulated to generate the depth-dependent wave transformation in comparison of uniform depth case to complicated depth case. Additionally, it shows that ship-induced waves have been reasonably generated by two ships passing each other and by a ship moving in a curve. Therefore, it is suggested that the FLOW-$3D^{(R)}$ model calibrated with observed data should provide more accurate prediction for the ship-induced wave in a certain fairway or harbor.

NUMERICAL ANALYSIS OF FLOW CHARACTERISTIC WITH DIFFERENT CORNER RADIUS OF SQUARE CYLINDER

  • Gao, Zhefeng;Sohn, Chang-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.315-319
    • /
    • 2010
  • The near wake of square section cylinders with different corner radii is studied by numerical method to investigate the influence of corner radius. Eight models, R/D=0, 0.05, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5 (R is the corner radius and D is the characteristic dimension of the body) at Re=500 were studied. The numerical results of St, CD and CL at R/D=0 and R/D=0.5 were compared with experiments to prove the feasibility and also investigate the trend of flow phenomena by the various radius corners. Results indicate that, as R/D ratio is increased, the Strouha lnumber is increased, the minimum pressure point on the cylinder surface moved own stream. The calculated results shows that between R/D=0.15 to R/D=0.3 have CD and CL.

  • PDF

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

A Numerical Study on the Flow Uniformity according to Chamber Shapes Used for Test of the Semi-Conductor Chip (반도체 칩 테스트용 챔버 형상에 따른 유동 균일성에 대한 수치적 연구)

  • LEE, DAEGYU;MA, SANG-BUM;KIM, SUNG;KIM, JEONG-YEOL;KANG, CHAEDONG;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.480-488
    • /
    • 2020
  • This study was conducted to improve the flow uniformity inside the chip tester through changing the flow path formation according to the inlet and outlet position of chamber. The internal flow and velocity distributions of the modified chamber models (Cases 1-3) were compared with the reference chamber model through three-dimensional Reynolds-averaged Navier-Stokes equations with k-ε turbulence model. The modified chamber models showed the superior flow uniformity characteristics compared to the reference chamber model. To investigate the flow uniformity in the chip tester, the standard deviation of the velocity was defined and compared. Through the internal flow analysis and assesment of the standard deviation, Case 2 among the test cases including the reference model showed the best flow uniformity generally.

Analysis of the Metal Flow in H-Beam Rolling using Beam Blank (빔 블랑크를 이용한 H 형강 압연 거동 연구)

  • Kim, J.M.;Choi, W.N.;Park, C.S.;Kim, K.W.
    • Transactions of Materials Processing
    • /
    • v.22 no.7
    • /
    • pp.383-388
    • /
    • 2013
  • Metal flow of the beam blank during H-beam rolling was examined in order to correlate the rolling defects with the beam blank configuration. For this purpose, H-beam rolling was performed on the beam blank where stainless steel bolts were inserted as the marker at the web and flange. The positional variation of the marker was monitored at each rolling pass, and the result was compared with the 3D FEM simulation employing the point tracking function. The simulation results were reasonably agreed with the experimental within the error of 0.5~1mm on both web and flange of the H-beam. It is anticipated that the 3D FEM simulation employing the point tracking function provides the guidance information on analyzing the correlation between the rolling defects and the beam blank configuration in H-beam rolling.

Discharge Coefficient of Side Weir for Various Curvatures Simulated by FLOW-3D (FLOW-3D를 이용한 다양한 곡률에 대한 횡월류 위어의 유량계수 산정)

  • Jeong, Chang Sam
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.1
    • /
    • pp.5-13
    • /
    • 2015
  • In this study, the lateral overflow discharge coefficients for the curvatures of side weir on meandering channel were analyzed. The side weir installed in accordance with the variation of the radius of curvature of the central angle bends with $180^{\circ}$. FLOW-3D model is applied to calculate the discharge coefficients of the side-weir on meandering and straight channels and the characteristics of the discharge coefficients are analysed. In order to verify the numerical model, the results from the hydraulic experiment conducted by the former research are compared with the results simulated by FLOW-3D in the same conditions. The discharge coefficients are calculated for the ratio between curvature ($R_c$) and channel width (b), and the ratio between over flow discharge of the straight channel ($Q_{wc}$) and the meandering channel ($Q_{wc}$) are compared. As the result, the discharge coefficients depend on the weir depth on upstream, and the radius of curvature, so that the discharge coefficients of side weir on the meandering channel can be estimated by them on the straight channel.

STRUCTURAL INTEGRITY EVALUATION OF NUCLEAR FUEL WITH REDUCED WELDING CONDITIONS

  • Park, Nam-Gyu;Park, Joon-Kyoo;Suh, Jung-Min;Kim, Kyu-Tae;Jeon, Kyeong-Lak
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.347-354
    • /
    • 2009
  • Welding is required for a connection between two different components in the nuclear fuel of a pressurized water reactor. This work relies on a mechanical experiment and analytic results to investigate the structural integrity of nuclear fuel in a situation where some components are not welded to each other. A series of lateral vibration tests are performed in a test facility, and the test structures are examined in terms of dynamic behavior. In the tests, the displacement signal at every grid structure that sustains fuel rods is measured and processed to identify the dynamic properties. The fluid-elastic stability of the structure is also analyzed to evaluate susceptibility to a cross flow with an assumed conservative cross flow distribution. The test and analysis results confirm that the structural integrity can be maintained even in the absence of some welding connections.

Estimation and Uncertainty Evaluation on Mass Flow Rate of Air Intake by Using Air Data (비행정보를 이용한 흡입구의 공기유량 추정 및 불확도 평가)

  • Park, Iksoo;Park, Jungwoo;Ki, Taeseok;Choi, Jin;Lee, Juyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • An estimation law of air mass flow rate for high speed engine control is presented. The variables of mass estimation equations are modified to measurable variables which can be obtained during flight, and the effectiveness of each variable to the estimation accuracy is evaluated. The equation is modified to a simplified form, and the uncertainty is evaluated. In addition, reference data for the selection of estimation methods is suggested by considering the sensitivity analysis of sensor error.

Numerical Analysis of Axial-Flow Cyclone Separator for Subway Station HVAC System Pre-Filter

  • Kim, Myung-Joon;Kim, Ho-Joong;Kwon, Soon-Bark;Kim, Se-Young;Kim, Jin-Kwan;Shin, Chang-Hun;Bae, Sung-Joon;Hwang, Sun-Ho;Kim, Tae-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.3
    • /
    • pp.94-99
    • /
    • 2009
  • In the Korean subway station, three types of pre-filters, which include auto filter, electrostatic precipitator (ESP) and auto cleaning demister, are widely used. However, these devices have some problems such as the difficulty of maintenance and high operating cost. In this study, axial-flow cyclone separator was employed as a pre-filter inside a heating, ventilation, and air conditioning (HVAC) system. 3-dimensional computational fluid dynamics (CFD) analysis was performed on a single unit axial-flow cyclone and coupled unit axial-flow cyclone. Calculated and measured pressure drop of the designed axial-flow cyclone were found be comparable to other types of pre-filters and the observed cut-off diameter was less than 10 micron. Considering lower operating and maintenance cost, axial-flow cyclone was proved to be a better solution as a pre-filter.

Physical Habitat Modeling in Dalcheon Stream Using Fuzzy Logic (퍼지논리를 이용한 달천의 물리서식처 모의)

  • Jung, Sang-Hwa;Jang, Ji-Yeon;Choi, Sung-Uk
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.229-242
    • /
    • 2012
  • This study presents a physical habitat modeling of adult Zacco platypus in a reach of the Dalcheon Stream located downstream of the Goesaan Dam. CASiMiR model is used to estimate habitat suitability index based on the fuzzy logic. Results are compared with those from River2D model, which uses habitat preference curve for habitat suitability index. Hydraulic data simulated by River2D are used as input data for CASiMiR model after verification against field measurements. The result shows that the habitat suitability of the adult Zacco platypus is maximum around the riffle area located upstream of the bend. CASiMiR and River2D estimate the maximum weighted usable areas at the discharge rates of 7.23 $m^3/s$ and 9.0 $m^3/s$, respectively. Overall comparison of the two models employed in this study indicates that CASiMiR model overestimates the weighted usable area by 0.3~25.3% compared with River2D model in condition of drought flow (Q355), low flow (Q275), normal flow (Q185), and average-wet flow (Q95).