• Title/Summary/Keyword: FIR

Search Result 1,190, Processing Time 0.035 seconds

An Analytical Approach for Design of Nth-band FIR Digital Filters with Equi-Ripple Passband

  • Moon, Dong-Wook;Kim, Lark-Kyo;Lim, Cheng-Chew
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.423-428
    • /
    • 2009
  • In FIR (Finite Impulse Response) filter applications, Nth-band FIR digital filters are known to be important due to their reduced computational requirements. The conventional methods for designing FIR filters use iterative approaches such as the well-known Parks-McClellan algorithm. The Parks-McClellan algorithm is also used to design Nth-band FIR digital filters after Mintzer's research. However, a disadvantage of the Parks-McClellan algorithm is that it needs a large amount of design time. This paper describes a direct design method for Nth-band FIR Filters using Chebyshev polynomials, which provides a reduced design time over indirect methods such as the Parks-McClellan algorithm. The response of the resulting filter is equi-ripple in passband. Our proposed method produces a passband response that is equi-ripple to within a minuscule error, comparable to that of Mintzer's design method which uses the Parks-McClellan algorithm.

The effect of Far-infrared on survival rate and genetic mutation of Escherichia-coli (원적외선이 대장균의 생존율과 돌연변이에 미치는 영향)

  • Kim, Jae-Yoon;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.637-642
    • /
    • 2001
  • Hershel found out Infrared for the first time, in the Industrial Revolution the Infrared and FlR had been begun to use making products. FIR with low temperature can deeply penetrate on the human body composed things without troublesome. since FIR has effectively operated on the human body at low temperature (35-40$^{\circ}$C). When FIR penetrated on the human body, it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FIR's receptors in the body, it colud be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process. and Heat shock protein. To radiate optimized FIR, in this study, we made the FIR radiation compound and instrument for unharming biological things. According to the results, the FIR radiation to E. coli., it did not induce genetic mutations and change the survival rate of E.coli.

  • PDF

Fast short length running FIR structure in discrete wavelet adaptive algorithm

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.19-25
    • /
    • 2012
  • An adaptive system is a well-known method for removing noise from noise-corrupted speech. In this paper, we perform a least mean square (LMS) based on wavelet adaptive algorithm. It establishes the faster convergence rate of as compared to time domain because of eigenvalue distribution width. And this paper provides the basic tool required for the FIR algorithm whose algorithm reduces the arithmetic complexity. We consider a new fast short-length running FIR structure in discrete wavelet adaptive algorithm. We compare FIR algorithm and short-length fast running FIR algorithm (SFIR) to the proposed fast short-length running FIR algorithm(FSFIR) for arithmetic complexities.

A Low-power Decimation Filter Structure Using Interpolated IIR Filters (Interpolated IIR 필터를 이용한 저전력의 데시메이션 필터 구조)

  • 장영범;양세정
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.8B
    • /
    • pp.1092-1099
    • /
    • 2001
  • 본 논문에서는 무선 통신 시스템의 중간주파수 처리 단을 디지털로 신호 처리하는 DDC(Digital Down Converter)의 저전력 아키텍처를 제안한다. FIR 필터의 계산량을 줄이기 위해서 개발된 Interpolated FIR 필터가 DDC의 데시메이션 필터로 널리 사용되고 있다. 본 논문은 이와 같은 Interpolated FIR 필터의 개념이 IIR 필터에도 적용될 수 있음을 보이고, 전력 소모와 구현 면적이 기존의 Interpolated FIR 구조보다 더욱 감소된 Interpolated IIR 필터 구조를 제안하였다. CDMA IS-95 DDC 사양의 데시메이션 필터를 FIR 구조, Interpolated FIR 구조, IIR 구조, Interpolated IIR 구조로 구현하여 이 4가지 구조들의 전력소모와 구현 면적을 비교하였으며 제안된 Interpolated IIR 구조가 기존의 Interpolated FIR 구조에 비하여 15.2%의 소모전력 감소와 35.3%의 구현면적의 감소를 달성할 수 있음을 보인다.

  • PDF

Performance Analysis of the state model based optimal FIR filter (STATE MODEL BASED OPTIMAL FIR 필터의 성능분석)

  • Lee, Kyu-Seung;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.917-920
    • /
    • 1988
  • The effects of the errors due to incorrect a priori informations on the noise model as well as the system model in the continuous state model based optimal FIR filter is considered. When the optimal filter is perturbed, the error covariance is derived. From this equation, the performance of the state model based optimal FIR filter is analyzed for the given modeling error. Also the state model based optimal FIR filter is compared to the standard Kalman filter by an example.

  • PDF

A Study on the Window Function for the Design of 2-Dimensional FIR Filter with Variable characteristics (가변특성을 갖는 2차원 FIR 필터의 설계를 위한 창함수에 관한 연구)

  • Lee, Min-Ho;Park, Chong-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1320-1322
    • /
    • 1996
  • 기존의 창함수를 이용한 1차원 FIR 필터의 설계는 설계방법이 단순해 비교적 많이 사용되고 있으나 통과영역과 천이영역을 가변할 수 없다. 본 연구에서는 두 개의 영역을 가변할 수 있는 창함수를 사용하여 1차원 임펄스 응답을 구한 후 McCllenan 변환 방법을 이용하여 2차원 FIR 필터를 실현하여 특성을 비교하여 2차원 FIR 필터의 설계에 적용할 수 있음을 밝혔다.

  • PDF

T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques (3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교)

  • Jeong, Jee-Young;Yoo, So-Young;Jang, Kyung-Mi;Eo, Hong;Lee, Jung-Hee;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the usefulness of fast inversion recovery (FIR) and magnetization-prepared three dimensional gradient echo sequence (3D GRE) T1-weighted sequences for neonatal brain imaging compared with spin echo (SE) sequence in a 3T MR unit. Materials and Methods: T1-weighted axial SE, FIR and 3D GRE sequences were evaluated from 3T brain MR imaging in 20 neonates. The signal-to-noise ratio (SNR) of different tissues was measured and contrast-to-noise ratios (CNR) were determined and compared in each of the sequences. Visual analysis was carried out by grading gray-white matter differentiation, myelination, and artifacts. The Wilcoxon signed ranked test was used for evaluation of the statistical significance of CNR differences between the sequences. Results: Among the three sequences, the 3D GRE had the best SNRs. CNRs obtained with FIR and 3D GRE were statistically superior to those obtained with SE; these CNRs were better on the 3D GRE compared to the FIR. Gray to white matter differentiation and myelination were better delineated on the FIR and 3D GRE than the SE. However, motion artifacts were more commonly observed on the 3D GRE and flow-related artifacts of vessels were frequently seen on the FIR. Conclusion: FIR and 3D GRE are valuable alternative T1-weighted sequences to conventional SE imaging of the neonatal brain at 3T providing superior image quality.

  • PDF

fast running FIR filter structure based on Wavelet adaptive algorithm for computational complexity (웨이블렛 기반 적응 알고리즘의 계산량 감소에 적합한 Fast running FIR filter에 관한 연구)

  • Lee, Jae-Kyun;Lee, Chae-Wook
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.250-255
    • /
    • 2005
  • In this paper, we propose a new fast running FIR filter structure that improves the convergence speed of adaptive signal processing and reduces the computational complexity. The proposed filter is applied to wavelet based adaptive algorithm. Actually we compared the performance of the proposed algorithm with other algorithm using computer simulation of adaptive noise canceler based on synthesis speech. As the result, the frequency domain algorithm is prefer than the existent time domain. we analyzed the Wavelet algorithm, short-length fast running FIR algorithm, fast-short-length fast running FIR algorithm and proposed algorithm.

  • PDF

PATIAL DISTRIBUTION OF STAR FORMATION ACTIVITY ON NGC 253 BY FIR AND RADIO EMISSION LINES

  • Takahashi, H.;Matsuo, H.;Nakanishi, K.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.261-262
    • /
    • 2012
  • The aim of this research is to reveal the spatial distribution of the star formation activity of nearby galaxies by comparing CO molecular emission lines with the large area observation in far-infrared (FIR) lines. We report the imaging observations of NGC 253 by FIR forbidden lines via FIS-FTS and CO molecular lines from low to high excitation levels with ASTE, which are good tracers of star forming regions or photo-dissociation regions, especially spiral galaxies, in order to derive the information of the physical conditions of the ambient interstellar radiation fields. The combination of spatially resolved FIR and sub-mm data leads to the star formation efficiency within galaxy. The ratio between the FIR luminosity and molecular gas mass, $L_{FIR}/M_{H_2}$, is expected to be proportional to the number of stars formed in the galaxy per unit molecular gas mass and time. Moreover the FIR line ux shows current star formation activity directly. Furthermore these can be systematic and statistical data for star formation history and evolution of spiral galaxies.

The New Storage Technology: Effect of Far Infrared Ray (FIR) Ceramic Sheet Package on Storage Quality of Pork Loin

  • Lin, Liang-Chuan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.11
    • /
    • pp.1695-1700
    • /
    • 2003
  • A total of 30 pork loin sections were utilized to evaluate the effects of FIR ceramic sheet in PE and vacuum package on preserving the quality of chilled pork stored at 4 and $0^{\circ}C$. Based on meat color, results indicated that pork loin packaged in ceramic sheet and control treatment showed that the samples of the control treatment tended to darken gradually in comparison with the samples at 0 day, but FIR treatment had few changes. Among the total plate counts of sliced loin in PE and loin in vacuum package under different storage times at 4 and $0^{\circ}C$, results showed that FIR ceramic sheet package treatment had lower total plate counts and significant differences (p<0.05). In VBN value, both treatments tended to rise high with the increasing of storage time, but the FIR treatment was significantly lower (p<0.05) than the control treatment. Its results had a corresponding relationship with the total plate counts. Regarding the drip loss of sliced loin in PE and loin in vacuum package, it showed that FIR ceramic sheet package treatment had lower drip loss and significant differences (p<0.01). These results showed that the use of FIR ceramic sheet package, including PE and vacuum package, is an effective method of maintaining the quality of meat.